4.2 System Programming
Carrier Code Assignment
300
System Programming  4-53
DescriptionAssigns carrier codes. This allows the system to recognize a special
user-dialed carrier code in order to apply toll restriction. The
system disregards the assigned code and toll restriction is applied to
the numbers after the code.
Selection• Code number: 01 – 20
• Carrier code number: 10 digits (max.)
DefaultAll codes – Not stored
Programming1.Enter 300.
Display: Carrier Excepted
2.Press NEXT.
Display: CODE NO? ®...

Page 262

4-54 System Programming
4.2 System Programming
Toll Restriction — System Speed Dialing Boundary Class
301
DescriptionAssigns the Toll Restriction class for System Speed Dialing
numbers.
SelectionBoundary Class-1 / Boundary Class-2 / Boundary Class-3 /
Boundary Class-4 / Boundary Class-5
DefaultBoundary Class-1
Programming1.Enter 301.
Display: SSD Boundary
2.Press NEXT.
Display example: Boundary Class-1
3.Keep pressing SELECTuntil the desired selection is
displayed.
4.Press STORE.
5.Press END....

Page 263

4.2 System Programming
Toll Restriction — Class 2 – 5 Denied Codes
302–305
System Programming  4-55
DescriptionThese allow the user to specify which numbers are toll-restricted
for each toll restriction class as follows.
Program [302]: restricts COS number 2.
Program [303]: restricts COS numbers 2 and 3.
Program [304]: restricts COS numbers 2 – 4.
Program [305]: restricts COS numbers 2 – 5.
Selection• Code number: 01 – 20
• Toll restriction number: 11 digits
DefaultAll codes – Not stored...

Page 264

4-56 System Programming
4.2 System Programming
Toll Restriction — Exception Codes
306
DescriptionThis allows the user to assign numbers which are exceptions to toll
restriction specified in programs [302] – [305].
Selection• Code number:01 – 80
• Exception number:11 digits
DefaultAll codes – Not stored
Programming1.Enter 306.
Display example: Excepted Table
2.Press NEXT.
Display: CODE NO?®
3.Enter a code number.
Pressing NEXTalso can enter code number 01.
Display example: 01: ...........
4.Enter an...

Page 265

4.2 System Programming
Emergency Dial Number Set
309
System Programming  4-57
DescriptionStores up to five emergency numbers.
Emergency numbers are not subject to toll restriction, Account
Code – Forced/Verify - All modes, Electronic Station Lockout or
Remote Station Lock Control.
Selection• Code number: 1 – 5
• Emergency number: 11 digits (max.)
DefaultCode-01 = 911, Other Codes = Not stored
Programming1.Enter 309.
Display: Emergency Code
2.Press NEXT.
Display: CODE NO? ®
3.Enter a code number.
Pressing...

Page 266

4-58 System Programming
4.2 System Programming
Account Codes
310
DescriptionAssigns the account codes for Account Code Entry, Verify – All
and Verify – Toll modes. If Verify – All is assigned in program
[605] “Account Code Entry Mode”, an account code is required to
make an outside call. If Verify – Toll is assigned, an account code is
only required to override toll restriction.
Selection• Code number: 01 – 24
• Account code: 4 digits
DefaultAll codes – Not stored
Programming1.Enter 310.
Display: Account...

Page 267

4.2 System Programming
Automatic Pause Insertion Codes
311
System Programming  4-59
DescriptionAssigns up to 40 automatic pause insertion codes which are
checked with the outside outgoing call number. When one of the
codes is the same as the call number, the pause time assigned in
program [417] “Pause Time” is automatically inserted after the
code. If a second dial tone is sent from the Central Office, it is
convenient to assign the area code as the pause code.
Selection• Code number: 01 – 40
• Pause...

Page 268

4-60 System Programming
4.2 System Programming
Toll Restriction — Station Lock Boundary Class
312
DescriptionAssigns the Toll Restriction COS number when the Electronic
Station Lockout or Remote Station Lock Control is set.
SelectionCOS-2 / COS-3 / COS-4 / COS-5 / Disable
DefaultDisable
Programming1.Enter 312.
Display: LOCK Boundary
2.Press NEXT.
Display example: Boundary Disable
3.Keep pressing SELECTuntil the desired selection is
displayed.
4.Press STORE.
5.Press END.
ConditionsNone
Feature...

Page 269

4.2 System Programming
Outside (CO) Line Connection Assignment
400
System Programming  4-61
DescriptionUsed to identify which outside (CO) lines are connected to the
system. This prevents users from calling a line which is not
connected.
Selection• Outside (CO) line number: 1 – 6,  ( = all outside (CO) lines)
• Connect / Not Connect
DefaultAll outside (CO) lines – Connect
Programming1.Enter 400.
Display: CO Connection
2.Press NEXT.
Display: CO NO? ®
3.Enter an outside (CO) line number.
Pressing NEXTalso...

Page 270

4-62 System Programming
4.2 System Programming
Dial Mode
401
DescriptionEach outside (CO) line can be programmed for DTMF, pulse or call
blocking. This program assigns the selection to each line.
DTMF: The dialing signals from an extension, either tone or pulse, are
converted to tone signals and transmitted to an outside (CO) line.
Pulse: The dialing signals from an extension, either tone or pulse, are
converted to pulse signals and transmitted to an outside (CO) line.
Call Blocking: If the Central...