Home > Panasonic > Communications System > Panasonic Kx-T123211d Installation Manual

Panasonic Kx-T123211d Installation Manual

Here you can view all the pages of manual Panasonic Kx-T123211d Installation Manual. The Panasonic manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 71

until the desired mode appears 
~..............................11 
Description 
Outside calls can be transferred to any 
extension manually. 
Programming Table 
See page 7-3. 
l While an extension paired with the DSS 
Console having a conversation with outside 
calls, “With Transfer” mode allows you to 
transfer outside call by only pressing the DSS 
button of the DSS Console. 
e While an extension paired with the DSS Console 
having a. conversation with outside calls, “Without 
Transfer” mode allows you...

Page 72

: .......................... until the desired mode appears 
Man ....... .-Day/Night service is manually switched ....... 
default 
Auto 
......... 
Day/ Night service is automatically switched 
:. 
pjc-lmNEXTllSELECTlfi1 
. 
Description 
Allows Day/Night service to be selected 
manually or automatically. 
Programming 
1. 
Dial (06). 
“Day/Night Mode” will be displayed. 
In case of manual switching, refer to “Flexible 
Night Service” on page 4-38. 
In case of automatic switching, set the “Starting 
Time...

Page 73

r---------Until the desired day of the week appears 
1 
. to start at 1 o’clock for day service 
: to start at 9 o’clock for day service 
mm 
: to start at 12 o’clock for day service 
I 
I 
I ml-G-l : to start at 59 minutes 
I 
i - , CD=m.m : to start at 0 rninute........................default 
I 
l------ - until the desired mode appears 
r- 1 EF= 111 : to start at 1 o’clock for night service 
I 
: to start at 5 o’clock for night service.........default 
I 
II r-i-. 1 2 to start at 12 o’clock for night...

Page 74

Description 11. Press the MEMORY button. 
If you select the automatic switching mode for day/ 
night service, enter the starting time. 
Starting time can be programed for every day of the 
week. Refer to “Switching of Service Mode (Day/Night 
Service Mode)” on page 3-12. The LCD will stop blinking. 
12. Press the SELECT button. 
“Night: 500 PM” or “Night: None” will be 
displayed as the default value and “Night” will 
blink. 
Press the “q” button. 
“5” or “None” will blink. 
0 If “Night: None” will be...

Page 75

i............“....‘.....-until the desired extension group number (1 through 8) appears 
_.................................. 
until the desired mode appears 
Disable : to disable “Hunting’:.--....default 
Enable : to enable “Hunting” (all 8 groups) 
A=B : to assign the same of all 8 extension groups 
: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Description 
Enables programming to automatically locate 
an idle extension within the same...

Page 76

i................until the desired extension group number (1 through 8) appears. 
;” until the desired hunting type appears 
; 
; [ Terminate : searching for larger jack numbers upward ..... default-(all 8 groups) 
Circular : circular searching for other numbers 
A=m : to assign the same of all 8 extension groups 
~.,.............................~ 
Discription 
Specifies the order in which idle extensions 
are searched when “Call Hunting” is used. 
The “Terminate Mode” searches for idle 
extensions with...

Page 77

The selective use of this feature permits restricted dialing to specific stations. A Class of Service can be 
assigned to a particular station which prohibits or limits that station’s dialing ability. The following are the 
available eight Classes of Service. 
I Service Class 
1’ 2 3 4 5 6.7 8 
operator calls A D D D D D D D 
international calls A D D 
D D D D D 
I toll calls 
IA IA IE ID ID ID ID ID I 
I local calls(charged)l A I A I A I A I F I D I D I D I I I I I I I I I 
local calls A A A A A A G D...

Page 78

until the desired type appears 
type A . . . . . . . . . . . . . . . . . default 
type B 
type C 
. I 
Description 
Area types specific to local 
There are three area types telephone numbers can be selected for toll restrictions. 
available as shown below. 
Type A : 
Type B : 
Type C : Toll calls (long distance) Area code 
Exchange code 
Local calls .................................. 
Exchange code Subscriber number 
Toll calls (long distance) ........... Apa ,.ode 
Subscriber number 
Local calls...

Page 79

,................................... 
A=m : to select boundary class l...... default 
121: class 2 
131: class 3 
cl 4 :class4 
0 5 :class5 
cl 6 : class 6 
171 : class 7 
q : class 8 
Description Programming 
Dial (11).  “Toll Restriction”, if it is programmed, prohibits 
CO Operator Calls. However, the desired 
extensions can be permitted to call to CO 
Operator by programming a boundary number 
of service class. 
1. 
2. “Operator Class” will be displayed. 
CO Operator Calls are allowed at all the...

Page 80

~.~~.~.‘..‘.‘..~.‘.~....~ until the desired mode appears 
Restriction : will be restricted by a Service Class......:..default 
No Restriction: will not be restricted. 
Description 
Through programming, Toll restrictions (service 
classes 1 through 8) set for each extension can 
be applied to System Speed dialing, too. 
In the “Restriction” mode, System Speed dialing is 
restricted according to the Service Class. 
In the “No Restriction” mode, System Speed dialing 
is not restricted according to the...