Page 621

Chapter 6. Name and Message Assicjnments (FFG)Section 400-Programming
Call Waiting/OHVA Text Reply
Software Version:CPC-All (all versions); CPC-6 Version 2.0 or higherAddress: FF6 
7# (l-5)# CONF (NNNNNNNNNNNNNNN)#
DescriptionWhen a busy party receives an indication of an incoming intercom call, the
busy party can respond by sending a text message back to the caller.
The text message can be sent after a Call Waiting tone, an 
OfRook Voice
Announce, or a Call Waiting tone followed by 
Offhook Voice...

Page 622

Section 400-Programming
Chapter 6. Name and Message Assignments (FF6)
DlDlDNlS Text Name Assignment
Software Version:
CPC-B Version 5.0 or higherAddress: DID: FF6 
8# (l-200)# (1 or 2)# (0000-9999)# (NNNNNN)#
DNIS: 
FF6 9# (l-200)# (1 or 2)# (000019999)# (NNNNNN)#
DescriptionAssign DID/DNIS names of up to 6 characters long for specific DID/DNTS
numbers.
DID/DNIS text names can only be assigned via FF6 programming. The DID/
DNIS number must already be assigned to an extension, before you can
assign a name...

Page 623

7. Toll Restrictions (FF7)Use the FF7 program addresses in this chapter to perform Toll Restriction
Service (TRS) programming.
This chapter covers the following addresses:
FF7 Address
aliFF7addresses
Topic
An Overview of Toll RestrictionsPage7-2
FF7 I# l# (0 or l)#
t
1 International Calling For TRS TvDes 3-6
FF7 1#2#(0 or l)#DTMF Signaling During Incoming Calls For TRS
Types O-6
7-5
7-6
FF7 1#3#(1-15)#1 Maximum Dialed Digits For TRS Types 3-61 7-7
FF7 1# 4# thru lOl# (0 or l>#3-Digit Toll Restriction For...

Page 624

An Overview of Toll Restrictions
The DBS Toll Restriction Service (TRS) allows you to set restrictions on outgoing calls.
For example, TRS can prohibit long-distance calls and prevent after-hours calls. TRS
can also minimize non-business calls and reduce phone bills by permitting only 
long-
distance calls over designated trunks.
The DBS system supports up to eight different TRS types (see table below). A TRS
type can be assigned to each trunk to activate toll restriction.
Table 7-L. ,Toll restriction...

Page 625

Sectton 400~ProgrammingUtapter 7. Toll Restriction (FF7)
TRS Type Characteristics
5lProgrammable TRS type; all area codes and office codes are allowed by
default.
6l Identical to TRS type 5.
7l Cannot restrict any dialing.
NotesNew NANP Vialing Plan.Beginning with CPC-AlID3 Version 6.0, changes
to the North American Numbering Plan (NANP) are supported. These
changes affect TRS parameters, which is explained in the affected program
addresses in this chapter.
Table 7-2. NANP changes
(
1
1
1
C
I
I
I
9
C
L...

Page 626

Change
Long-Distance Calls
International Calls
Old Numbering PlanNew NANP Plan
(Versions prior to 6.0)(Version 6.0 or higher)
1) Check Special Area/Office Codes. 1) Check Special Area/Office Codes.
2) Check Area Code Table.2) Check Area Code Table.
3) Check Add/Delete Digits.
3) Check new Off’ce Code Restric-
tion Table (up to 10 entries).
4) Check Add/Delete Digits.
Allowed or restricted system-wideSelectable restriction on extensions
by TRS type assigned to trunk.if using trunks with TRS types 3-6....

Page 627

Section 400-ProgrammingChapter 7. Toll Restriction (FF7)
International Calling For TRS Types 3-6
Software Version: All VersionsAddress: 
FR I# 1# (0 or l)#
DescriptionUse this address to allow or deny international calls on trunks that are
assigned TRS types 3-6.
If the DBS is set to use the new NANP dialing plan (available with CPC-A
Version 4.0 or higher, and 
CPC-AII/B Version 6.0 or higher), this address
determines whether the DBS will check the Country Code Table for any
restrictions on the dialed...

Page 628

Chapter 7. Toll Restriction (FF7)Section 400~Programming
DTMF Signaling During Incoming Calls For TRS
Types O-6
Software Version: All VersionsAddress: 
FFi’ l# 2# (0 or l)#
DescriptionThis address determines if DTMF signaling can be sent to the CO after an
extension picks up an incoming trunk call.
If an extension receives a call on a trunk assigned to TRS type O-6, the
extension user may try to bypass ‘lRS restrictions by dialing an outgoing call
while still off-hook. (After the outside caller hangs up,...

Page 629

Section 400-Programming
Chapter 7. Toll Restriction (FF7)
Maximum Dialed Digits For TRS Types 3-6
Software Version: Ail VersionsAddress: FF7 
I# 3# (l-15)#
DescriptionThe maximum number of dialed digits on trunks assigned TRS types 3-6 can
be set from 15 to 29. By default, the maximum number is unlimited.
ProgrammingFF7 
l# 3# (l-15)#
f
Maximum Number of Dialed Digits Allowed
Note: The default setting is ** (unlimited). To change
the setting to a limited number of digits, enter 
l- 15
(see table below...

Page 630

Chapter 7. Toll Restriction (FF7)Section 400-Programming
3-Digit Toll Restriction For TRS Types 2-6
Software Version: All VersionsAddress: 
FR 1# (4-11)# (0 or l)#
DescriptionUse this address to to allow or deny the dialing of 211-911 numbers on trunks
that are assigned TRS types 2-6. By default, 
all of these numbers are allowed.
If the DBS is set to use the nm NANP dialing plan (available only with CPC-
All/B Version 6.0 or higher), “911” is always allowed for T.RS types 2-6,
regardless of the setting...