Page 631
secuon 4uu-rruyrarnrrw~y 7-Digit Toll Restriction For TRS Types 2-6 Software Version: All VersionsAddress: FR It (12-l 6)# (0 or l)# DescriptionUse this address to determine whether the DBS will check dialed 7-digit numbers against the “Special ‘I-Digit Table” (see FF7 6#). By default, the DBS will check the dialed number against the table; if it finds a match, the call will be denied, regardless of the area code. Programming IFF7 1# (12916)# (0 or l)# ‘IRS Types: 12=TRS type 2 13=TRS type 3 1GTRS...
Page 632
Dialing Plan Switch Sofhnrare Version:CPC-A Version 4.0 or higher; CPC-All/B Version 6.0 or higherAddress: FF7 l# 17# (0 or l)# DescriptionThis address allows you to choose between the new North American Numbering Plan (NANP) and the old dialing plan. By default, the old dialing plan is used. Selecting the new NANP dialing plan, in addition to supporting public network changes in dialing formats, also provides greater flexibility for “exceptions to the rule” --such as applying TRS restrictions to...
Page 633
Section 400-ProgrammingChapter 7. Toll Restriction (FF7)Operator Access Software Version:CPC-A Version 4.0 or higher; CPC-All/B Version 6.0 or higherAddress: FR 1# 18# (ExtPort)# (0 or l)# DescriptionThis Operator Access switch works only if the DBS system is set to use the new NAM dialing plan (FF7 l# 17# l#). Also, this switch applies only to TRS types 2-6 (TRS types 0 and 1 do not allow outbound dialing; TRS type 7 allows all dialing). Use this address to block extension(s) from being able to access...
Page 634
Chapter 7. Toll Restriction (FF7)Section 400-Programming International Calling on Extensions Software Version:CPC-A Version 4.0 or higher; CPC-All/B Version 6.0 or higherAddress: FF7 1# 19# (ExtPort)# (0 or l)# DescriptionThis address applies only to systems programmed to use the new NANP dialing plan (FF7 l# 17# l#). Also, this switch applies only to TRS types 3-6 (TRS types O-2 do not allow international dialing; TRS type 7 allows all dialing). Use this address to allow or deny international calling...
Page 635
Section 400-ProgrammingChapter 7. Toll Restriction (FF7) Country Code Table Software Version:CPC-A Version 4.0 or higher; CPC-All/B Version 6.0 or higherAddress: FF7 1# 20# (Table)# (Code)# Description ProgrammingThis address applies only to systems programmed to use the new NANP dialing plan (FF7 l# 17# l#). Also, this switch applies only to TRS types 3-6 (TRS types O-2 do not allow international dialing: TRS type 7 allows all dialing). In this address, the DBS provides a Country Code Table of up to...
Page 636
Lnaprer 1. I 011 nesrrlcnon (i-i- /Ibecnon 4oo-rrogramming Equal Access Code Format Software Version:CPC-A Version 4.0 or higher; CPC-All/B Version 6.0 or higherAddress: FF7 1# 21# (0 or l)# DescriptionThis address determines whether the old CIC (Carrier Identification Code) format can still be dialed to reach a preferred lXC (interexchange carrier). lOld dialing plan format is 10 XXX (where “XXX” is a 3-digit CIC). lNew NANP (North American Numbering Plan) format is 101 XXXX (where “XXXX” is a 4-digit...
Page 637
Section 400-ProgrammingChapter 7. Toll Restriction (FF7) Office Code Restriction Table For TRS Types 2-6 Software Version:CPC-A Version 4.0 or higher; CPC-All/B Version 6.0 or higherAddress: FF7 l# 22# (l-lO)# (OOO-999)# DescriptionThis address applies only to DBS systems set for the new NANP dialing plan(FF7 l# 17# l#). The Office Code Restriction Table allows up to 10 office codes (“exchanges”) to be restricted system-wide for all trunks assigned TRS types 2-6. The DBS will check this table before...
Page 638
Chapter 7. Toll Restriction (FF7)Section 400-Programming Area Code Table For TRS Types 3-6 Software Version: All VersionsAddress: FF7 2# (316)# (OOO-999)# (0 or I)# DescriptionUse this address to set area code dialing restrictions based on the TRS type assigned to a trunk. Callers accessing a trunk assigned to TRS types 3-6 are allowed or denied access to specific area codes according to the settings in this address. ProgrammingFF7 2# (316)# (OOO-999)# (0 or l)# t f TRS Type (3-6)Area CodeO=Allow...
Page 639
Section 400-ProgrammingChapter 7. Toll Restriction (FF7) Office Code Table For TRS Types 3-6 Software Version: All VersionsAddress: FF7 3## (3-6)# (OOO-999)# (0 or l)# DescriptionUse this address to allow or deny individual office code(s) for local calls based on the TRS type assigned to the trunk. ProgrammingFF7 3# (316)# (0001999)# (0 or l)# /( f t TRS Type (3-6)Office CodeO=Allow dialing. 1 =Deny dialing. Defaults -- TRS Type 3: 1 (Deny) TRS Types 4,5 and 6: 0 (Allow) Related ProgrammingSystem...
Page 640
Chapter 7. Toll Restriction (FF7)Section 400-Programming Special Area Code Table For TRS Types 3-6 Software Version: All VersionsAddress: FF7 4# (l-4)# (OOO-999)# DescriptionUse this address to enter up to four area codes that will be tied to ranges of office codes in the next address (FF7 5#). This allows you to set up special area/office code combinations that are “exceptions to the rule” -- for example, restricting calls to (800)976-xxxx numbers, while allowing (800) 977-xXxX numbers. These special...