Page 221
Section 300~InstallationChapter 7. Specifications Resource Paging (continued) No. of external paging zones No. of stations in external paging zone 00 No. of stations in external paging zones 0 l-04 Speed dialMaximums 5 No. of stations in the system No. of stations in corresponding paging group 0 l-04 No. of personal speed dial numbers No. of system speed dial numbers10 per extension 90 (00 - 89) or 2Oq (000-199) with CPC-AII and CPC-B Version 7.0 No. of digits per speed dial number (personal and...
Page 222
Chapter 7. SpecificationsSection 3004nstallation Part No.DescriptionQuantity DBS 10DBS 72DBS 96 Phone Options VB-433 1024-key expansion module (EM24)162836 VB -4332072-key DSS/BLF module (DSW72)CPC-A and CPC-AII: 4 CPC-B: 8 (up to 4 can be assigned as DSW72s; up to 4 can be assigned as Attendant Consoles) VB-438847 ft. handset cord VB-43885 15 ft. handset cord VB-4388625 ft. handset cord325672 VB-43890K-type handset Printed Circuit Cards VB-43110Cable kit for 2-system connectionN/AN/AN/A VB-43410Call...
Page 223
Section Zoo-installationChapter 7. Speci!icatlor!s Part No.i DescriptionIQuantitpIIjDBS40 lDBS72 iDBS96 / Expansion Connectors VB-43120Trunk expansion connector1VB-43121Extension expansion connector11 VB-4370 1 VB -43705 Doorbox Equipment (Trunk) Door box adaptor8”12”16* Door box16*24*32* Doorbox Equipment (Extension) VB -437 11Extension-Based Door box adaptor444 VB-43705Door box444 Optional Equipment VB-43706Remote Administration Interface @AI-A)11V-B -43707Remote Administration Interface @AI-B)1...
Page 224
ChaDter 7. SoecificationsSection 300~Instailation Table 7-10. Hardware maximums for do&e-cabinet systems Part No.DescriptionQuantity ++++++sg gsixeswm gggg gg ggkg yg =c CEi Elf Q,r3 cc: =a PhonesVB-43210 l&key keyphone w/ handsfree answerbackVB-43220 22-key keyphone w/ handsfree answerback VB-4322 122-key speakerphone VB-43223 22-key speakerphone w/LCD display56 72 104104128 144 VB-43225 22-key speakerphone w/ large LCD displayVB-43230 34-key keyphone w/ handsfree answerback VB-4323 1 ,34-key...
Page 225
Section 300~InstallationChapter 7. Specifications L1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Part No.DescriptionIQuantity Print zd Circuit Cards CrB-43 1101 Cable kit for 2-cab. systems11 irB-43410Call processor card (CPC-A) a-4341 1Call processor card (CPC-B) a-434 12Call processor card (CPC-AU)m-43420 Service circuit card (SCC-A) irB-43421Service circuit card (SCC-B) irB-43431DTMF signal receiver for 8 (L-TRK/4) irB-435 118-port loop-start trunk card (L-TRK/Q irB-43541 8-port Direct-inward-dialing 33 trunk...
Page 226
Chapter 7. SpecificationsSection 300~Installation Part No.DescriptionQuantity ++++++ s %R$cF3 s82gg vl*mminmz?~~wHu3SaZ~ZsiCCac3CQ Expansion Connectors VB-43120Trunk connectorexp.222222VB-43121Ext. connectorexp.1*0” Doorbox Equipment (Trunk Port) VB -4370 1Door box adaptor12#12# 2M 2#28#32# VB-43705Door box24# 24# 40#48# 56# 64# Doorbox Equipment (Extension Port) VB-437 11Doorbox adaptor444444 VB-43705Doorbox444444 Optional Equipment VB-43706Remote Administration Interface (R-41-A) VB-43707Remote...
Page 227
Section 300~InstallationChapter 7. Specifications Cabling Specifications Table 7-11. Maximum cabling distances Loop Type and Resistancetesistance Key phone, EM/24 DSSl72 SLT100 Ohms OPX (Loop between the DBS and the OPX Adaptor) OPX (Loop between the OPX Adaptor and a pushbutton SLT) Doorphone (Loop between the DBS and the Doorphone Adaptor) Doorphone (Loop between the Doorphone Adaptor and the Door- phone) Voice hmounce Unit10 Ohms 40 Ohms 20 Ohms 10 Ohms 900 Ohms (excluding end impedance) 10 Ohms 40...
Page 228
Cliapter 7. SpecificationsSection 300~Installation Communication Parameters Tuble 7-12. Voice path from KTELs to DBS n ChannelOverall conununicadons path 1 D-channel data 1256 kbps 116 kbps 1 B-channel data164 kbps Table 7-13. Data communications portsParameters ISMDRInterfaceRS233-CBaud rate 300,1200,4800 or 9600 kbps ParityEven, odd, or none Stop bit length1, 1.5, or 2Data bit length5, 6,7, or 8 1Maintenance(RAIcard)Baud rate300 (RAI-A) or 300 or 1200 (RAI-B) Stop bit length1Data bit length 8...
Page 229
Section 3004nstallationChapter 7. Specifications Signaling Characteristics Table 7-14. Signaling to CO ItemSpecification Dial pulse8 to 11 pulses per second (PPS) Break ratio 58 to 64% Minimum pause0.7 to 1.0 seconds Trunk startLoop or ground start Table 7-15. Signaling le vets ItemLevelDistortion Trunk input (DISA)-40 dBm (minimum)Less than 10% Output from DBS (at MDP) High level: -8 dBm (minimum) Low level: -10 dBm (minimum) Analog station input (Dial-35 dBm (minimum)Less than 10% status) Analog...
Page 230
Chapter 7. SpecificationsSection 3004nstallation Tone Characteristics Table 7-17. Tone Plan Tone NameFrequencyTiming (seconds) CO Call Tones CO incoming call550/400 Hz at 16 HzProgrammable Hold recall 550/400 Hz at 16 Hz0.5 on/35 off Transfer recall550/400 Hz at 16 Hz0.5 on/35 off Trunk queuing550/400 Hz at 16 Hz0.5 on/O.5 off/O.5 on/2.5 off CO ofiook signal550 Hz1 on/7 off Internal Tones (Key Phones) Dial tone400 HzContinuous CO incoming call 550 Hz1 on/3 off (Prior to CPC-B 3.1) Programmable (CPC-AII...