Section 300~installationChapter 6. Double-Cabinet Systems ‘igure 6-6. Slot usage for two-cabinet systems, DBS 96 tu DBS 96DBS 96 (Slave) i 1 ~ EC2 EC3EClEC5EC7EC8CPCAUX 1 -l’RK TRK 2 3AUX 2DBS 96 (Master) EC2 EC3 -I- EC4 EC5 ECtTRK TRK TRK EC1 1 2 3 *See “Tl Interface” on page 4-l 1 for EGTRK port numbers for Tl. #A maximum of twoMFR cards can be installed in a two-cabinet system. With Cable Kit Version 1.1, one MFR is installed in the Master AUX 1, and one MFR is installed in the Slave AUXl . With Cable...
Page 212
Chapter 6. Double-Cabinet Systems Section 300~installation Installation 1.Install the trunk and extension cards according to the layouts shown in the Figures 5-l through 6-6. Note:The port numbers for each slot are fixed. 2.If you are using two MFR cards, cut Strap S3 on the second card. Figure 6-7. Strap 3, MFR cardI 3.Using the cables provided, connect the CBL-M card in the master cabinet to the CBL-S card installed in the slave cabinet. Note: The EM1 filter must be installed as close to the cabinet as...
Page 213
Section 300~InstallationChapter 6. Double-Cabinet Systems Double-cabinet insWation 4.Connect two 24V power supply cords from the CBL-S card to the 24V and GND terminals on CN2 of the Connector Panel of the slave cabinet. Figure 6-9. CBL-S to Connector Panel connection, si’uve cabinetDBS-70-300DBS Manual - Issued 6/t/956-11
Page 214
Chapter 6. Double-Cabinet SystemsSection 300~Installation 5.Set SW1 on the CBL-M card according to the following table. Table 6-2. CBLM switch settings System Corn binationsISwitch Settings DBS96DBS72OFF ONOFF ONON OFF OFF OFF DBS96DBS96OFF ON OFF ON ON OFF OFF OFF 6-12 DBS Manual - issued 6/l/95DES-70-300
Page 215
Chapter 7. Specifications This chapter contains frequently referenced DBS specifications. Note: All maximums may not be attainable simultaneously. Also, attainment of some maximums depends on levels of feature usage and optional hardware requirements. Though every effort has been made to ensure the accuracy of these specifications, Panasonic does not warrant them in regard to merchantability or fitness for a particular purpose. Specifications are subject to change without notice. This chapter covers the...
Page 217
Section 300~InstallationChapter 7. Specifications Electrical CharacteristicsTable 7-l. Input power EquipmentAll DBS cabinetsPower Requirements120V AC + 10 % 60 Hz DBS key phones 13 watts maximum (powered from the DBS) T&e 7-2.Power consumption and heat generation System status Power Consumption (in Watts) Withno traffic170250320340420500490570640withmax. traffic 216324444432540648660768888 Heat Generation (Btu per hour) Withno traffic5808531092116014331706167219452184 Withmax. traffic...
Page 218
Chapter 7. SpecificationsSection 300-Installation Environmental Requirements Table 7-4.Temperature and humidity requirements Environmental Conditions Requirements Temperature32 to 104’ F (0 to 40’ C) /Relative Humidity Table 7-5.Dimensions and weight, sing&-cabinet systems and phones PhysicalDBS40DBS72 Characteristics _,, DBS96 Cabinet Dimensions (H x W x D in inches) 121 x15 x9.35121 x19.5x9.4121 x19.5x9.4 1 VB-432254 l/8 x 7 318 x 9 1 Other key phones3 314 x 7 318 x 9 DSLT3 l/8 x 7 318 x 9 l/8 DSSl723...
Page 219
Section 300~InstallationChapter 7. Specifications Resource Maximums Table 7-7.Trunk and line capacities System Resources Trunk ports Extension ports Expansion ports Trunk/Extension speech path switching816 24 16 24 32 32 40 48 24 48 64 48 72 96 88112 128 8 I8 18 1818*116116 116 nonblocking Notes: *Beginning with CPC-B Version 4, the EC/TRK slot in the slave DBS 72 can be used for trunks or lines. Prior to CPC-B Version 4, this slot could only be used for lines. CPC-AI1 also allows this. Table 7-8....
Page 220
Chapter 7. Specifications Section 300~Installation SCC-A ResourceMaximums Conference circuits 3 four-party circuits KC-B with CPC-B SCC-B with CPC-A and CPC-AI1 8 four-party circuits 3 four-party circuits No. of incoming authorization codes No.of outgoing authrorization codes 1 2 1 No.of digits in each authorization codeI4I I--~HuntingI [No. of groups8 No. of stations in a group8 Least cost l.Outing 11 Area Code table 1 Office Code table 4 Special Area Code tables 4 Special Office Code tables No. of...