Page 181
Section 300~installationChapter 5. Peripheral Equipment 3.Connect the zone relays to the amplifier. 4.Connect the zone relays to the +24V and zone paging terminals (20-24) on the Connector Panel. ‘igure 5-7. External zone paging instdlation (RCA~ector) . . ---46V SG SYN RG +24V GND C6 M i!O 21 22 if3 24 RE2 REl joIo/olololololojololololo~ololo~ Ii I - Zcme Relay:Use Aromat RelayType DF2E-24V(avallable as Stcck% 46F6752 at5Newark ElectronicsCN2 I i-6004-NEWARK)or Similar Relay Audb InputMbOutput Note:...
Page 182
Chapter 5. Peripheral EquipmentSection 3004nstallation External General Page/UNA Installation Use this procedure to connect a general page system, connect UNA over a page system or connect a combined page/UNA system. 1.Connect CN4 on the DBS Connector Panel to the audio input of the paging amplifier. (See Figure 5-8.) 2.Connect the audio output of the amplifier through the C and M relay terminals to the speaker(s) as shown in Figure 5-8. Figure 5-8. External general pagelUNA insMution (RCA ki%kstor)...
Page 183
Sectlon 300~InstallationChapter 5. Peripheral Equipment lIf UNA operates over the paging system, the Audio Output of CN4 provides the Audio Ringback sound to be heard over the paging system when a trunk rings UNA. lIf UNA operates over the paging system, the UNA ringing will always takes precedence over paging. When a page is inteiTupted in progress, the pager must hang up and wait until after UNA ringing ends to reinstate the Page. lIf UNA rings over the paging system, set the Ring Patterns for UNA...
Page 184
Chapter 5. Peripheral Equipment Section 300~installationInstallation 1.Connect the external ringer to the “C” and “M” terminals on the Connector Panel. (See Figure 5-9 on page 5-18.) Note: When the Ring Patterns for UNA Terminals (M, C, & B) programming command (FF12#4# l# (0 or l)# is set to 0, connecting the ringer to the “C” and “M” terminals provides a “1 second on/3 seconds off’ ringing pattern and connecting to “C” and “B” terminals provides a “1 second off/3 seconds on” ringing pattern....
Page 185
Section 300~installationChapter 5. Peripheral Equipment Power -Failure Unit Guidelines lUp to four SLTs can be connected to the Power Failure Unit (VA-43703). If a power failure occurs, the SLTs will automatically receive dial tone directly from the central office. DBS features and restrictions do not apply when the SLTs are receiving dial tone from the CO. lIf a call is in progress through the Power Failure Unit (PFU) when the power is restored, the call will be disconnected. lThe following tools are...
Page 186
Chapter 5. Peripheral EquipmentSection 300~Installation Figure S-10. Cable punch-out phte‘ower Failure Unit 3.Mount the PFU on the wall using the three screws provided with the unit. (See Figure 5- 11. j. 4.Connect the trunks from the central office to the PFU. 5.Connect the SLTs to the AEC extension ports on the PFU. 6.Connect the trunks from the DBS to the PFU. 7.Connect the AEC ports from the DBS to the PFU. When a power failure occurs, AEC “A” is switched to Trunk “A,” AEC “B” is switched to Trunk...
Page 187
Section 300~InstallationChapter 5. Peripheral Equipment Fromrhe MainCabinetAEC Exrension Porl No.AEC Extension Pan NO. il AEC Extension Port No. AEC Extension Port NO. A :0 A :.D ToTRK Pan No. the MainTRK Potl NO. Cabinetc TRK Porl No. TRK Port No Figure 5-11. Power Failure Unit (PFU) instdldion To the Central Olfice To +24V and GND on CN2 of the Main Cabinet (no polarization) DBS-70-300DBS Manual - Issued 8/l/955-21
Page 188
Chapter 5. Peripheral EquipmentSection 3004nstallarion Voice Announce Unit (VAU) Guidelinesl Operating temperatures for the Voice Announce Unit (VB-43708) should be between 35 and 105’ F.l Maximum loop resistance for the VAU is 10 Ohms.l The VAU contains a rechargeable lead-acid battery. Recharging circuity for the battery is included on the VAU.l The ports used for the VAU must have all.FF key assignments cleared before voice messages and abbreviated dial numbers are programmed.l The following tools...
Page 189
Section 300~InstallationChapter 5. Peripheral Equipment Table 5-7.Switch seltings for delay answer timing, VAU Switch Block 2 (SW2) Delay Answer Timer (Switches l-3) SwitchTimer (in seconds)4 8 12 16 20 24 28No Answer (VAU 1.1 orbelow) or Immediate Answer (VAU 1.2 or above) 1OFF OFF OFF OFF ON ON ON ON 2OFF OFF ON ON OFF OFF ON ON 3OFF ON OFF ON OFF ON OFF ON Table 5-8.Switch settings for DTMF detection timing, VAU 1 DTMF Detection Timer VAUSwitch Versionblock and switch 1.1 or aboveSW2, pin 4 1.0 or...
Page 190
DOCIIU~ mu-insrarlarm Table S-IO. Switch settings for abbreviated dialing digit length, VAU Switch Block 2 (SW2) Abbreviated Dialing Digit Length (Switches 7-8) SwitchNumber of Digits 1 Digit2 Digits3 Digits 7OFFOFFON 8OFFONOFF 3.Remove the cable punch-out plate (Figure 5-12) to make an opening for the cable coming into the VAU. To remove the plate, cut the grooves on either side with diagonal shears. Then bend the plate back and forth with needle-nose pliers to remove it. Figure 5-12. Cable punch-out...