Page 291
Description / Function Component Guides the original over the scanner to the front. original guide - When to do The copy and scan quality can decrease if ■ the transparent contact plates (8) are dirty or static. ■ The original support rollers (5) are dirty and you use transparent originals. In that case you must clean the scanner to ensure top quality output. How to clean the scanner 1. Use both hands to push up the left and right scanner open levers (4) to fully open the scanner top cover (3)....
Page 292
A locking mechanism prevents the scanner top cover from closing. Caution: To clean the scanner use the soft lint-free Masslin towels from the scanner cleaning kit. 2. Use a Masslin towel that has been moistened with water and firmly wrung out to clean the following parts of the scanner. Chapter 7 - Maintain the Océ ColorWave 300 multifunction printer292Clean the scanner Downloaded From ManualsPrinter.com Manuals
Page 293
■ the original support rollers (5) Rotate the rollers to clean them. ■ the transparent contact plates (8) Wipe off any soiled areas. 3. Wipe all the cleaned parts once again using a dry Masslin towel. Warning: Take care not to get your fingers caught in the scanner top cover. 4. Press the scanner top cover down gently with both hands to close it. Note: Check that the left and right scanner open levers are locked into position. Chapter 7 - Maintain the Océ ColorWave 300 multifunction printer...
Page 294
Calibrate the scanner Introduction You can calibrate the scanner when you are not satisfied with the copy or scan quality. Use the calibration wizard on the printer user panel to calibrate the scanner. Before you begin Clean the scanner before you start the calibration procedure. Dirty parts of the scanner causes a decreased copy and scan quality. (See ‘Calibrate the scanner’ on page 294 ). Caution: Handle the calibration sheet with care. Caution: Do not touch the black area of the calibration...
Page 295
5. Insert the scanner calibration sheet¹ as instructed in the wizard. 6. Press the start button to start the scanner calibration. The message 'Calibrating, please wait... do not open the scanner.' appears. Note: 'Calibrating the scanner takes between 5 to 10 minutes.' Note: ¹ The scanner calibration sheet code number is 97002634. Chapter 7 - Maintain the Océ ColorWave 300 multifunction printer 295Calibrate the scanner Downloaded From ManualsPrinter.com Manuals
Page 296
Chapter 7 - Maintain the Océ ColorWave 300 multifunction printer296Calibrate the scanner Downloaded From ManualsPrinter.com Manuals
Page 298
The printer Overview Definition This table gives an overview of the possible error messages and system messages of the printer and refers to the possible solution. # Description / solution Error message / System mes- sage The media required for the job is not available on the printer. See ‘Replace / Install the media’ on page 272 'Required media not available' The end of the roll of media is reached while you print See ‘Replace / Install the media’ on page 272 'Roll empty' A...
Page 299
# Customer action Description Error code Replace the printhead by using the wizard. Note: Never re-insert a printhead that has caused this problem. Excessive leakage current detect- ed for head [1…9] Printhead failing Replace printed [1…9] 4501 - 4509 Printhead is probably not placed correctly. Remove and re-insert the printhead at the original position. Note: If the problem persists you must replace the printhead. Head defective during printing 4551 - 4559 You can ignore this problem by...
Page 300
Cover or door opened Cover or door opened When you open a cover accessing the wizard, the system produces a double warning signal. When you open a door or cover during printing, the printer stops. A message on the printer user panel tells you to close the cover. Close the cover to continue. Examples: Chapter 8 - System messages and solutions300Cover or door opened Downloaded From ManualsPrinter.com Manuals