P0603534  02Modular ICS 6.1 Installer Guide
maximum value for that service type or if they will use lines 
needed to maintain the minimum value of other service types.
The summation of the minimum values for incoming or 
outgoing PRI services cannot exceed the total number of lines 
in the PRI pool. 
The maximum value for an incoming or outgoing PRI service 
cannot exceed the total number of lines in the PRI pool. 
Programming Call by Call Limits
With the card set to PRI and the...

Page 462

462 / System prgrming
Modular ICS 6.1 Installer GuideP0603534  02
13. Press ‘. The display shows Max outgoing:23. 
14. Press CHANGE
 to enter a different number. 
Release ReasonsInstaller password required
This feature is useful for diagnostic purposes. It shows the 
reason why an ISDN call has been released. The Release 
Reason can be displayed as Simple or Detailed text. When the 
default None is selected, no release reasons appear on the set. 
Release Reasons can be programmed under System prgrming....

Page 463

System prgrming / 463
P0603534  02Modular ICS 6.1 Installer Guide
Programming Hospitality Services
The Hospitality heading accesses the settings for the room and 
alarm information.
With the display showing System prgming press ‘ 
until the display shows Hospitality.
Room/desk information
Use this setting to assign set DNs to a specific room.
1. At the Hospitality heading, press ≠. 
Room/desk info displays.
2. Press ‘. Show set: displays.
3. Enter a room set number or press LIST
 and press 
‘ until you...

Page 464

464 / System prgrming
Modular ICS 6.1 Installer GuideP0603534  02
Call restrns
You can set up call restrictions based on room occupancy 
states. This setting affects the Room occupancy feature.
1. At the Hospitality heading, press ≠ . 
Room/desk info displays. 
2. Press ‘. Call restrns displays.
3. Press ≠. Vacant:00 displays.
4. Press CHANGE 
and enter the filter that defines the 
restrictions for your hospitality system. Refer to Filters on 
page 339
5. Repeat steps 2 and 3 for the other room occupancy...

Page 465

System prgrming / 465
P0603534  02Modular ICS 6.1 Installer Guide
Setting Service times
You can set the time when occupied rooms change from 
Service done to Service required. This setting affects the 
Room condition feature.
1. At the Hospitality heading, press ≠ . 
Room/desk info displays. 
2. Press ‘ until Service time displays.
3. Press ≠. Hour: 00 displays.
4. Press CHANGE
 and enter the hour (00 to 23). 
If the number is less than 13, the display shows AM. Press 
CHANGE
 to select PM, if required....

Page 466

466 / System prgrming
Modular ICS 6.1 Installer GuideP0603534  02
8. Press CHANGE until you find the number of seconds you 
want (10, 15, 20, 30, 40, 50). 
9. Press ‘. Time format:12 hr displays.
10. Press CHANGE
 to choose either 12hr or 24hr. 
11. Press ‘. Expired alarms displays.
12. Press ≠. Notify set:None displays.
13. Press CHANGE
 to enter a set DN to be notified. 
14. Press ‘. Use tone: N displays.
15. Press CHANGE
 to choose either Y (yes) or N (no). 
SM sets
You can assign a maximum of 30...

Page 467

Network Services / 467
P0603534  02Modular ICS 6.1 Installer Guide
Network Services
The headings that appear under Network Services, depends on 
which profile the system is running. 
Profiles 2 allows ETSI line connections, therefore, systems 
running this profile may have access to the two ETSI features. 
The service provided on the line by your service provider 
determines if these features are available.
Profiles 1, 2, and 4 support MCDN over PRI SL-1 lines.
ETSI: Network diversion and MCIDInstaller...

Page 468

468 / Network Services
Modular ICS 6.1 Installer GuideP0603534  02
Network Call Diversion
Norstar Network Call Diversion (NCD) is a network function 
that allows forwarding and redirection of calls outside the 
Norstar network when using an ETSI ISDN line. Functionality 
is similar to that of External Call Forward (ECF).
NCD redirects calls using the same line on which they arrive. 
Call forward is efficient since there is no need for additional 
outside lines.
Forwarding calls externally from an...

Page 469

Network Services / 469
P0603534  02Modular ICS 6.1 Installer Guide
• Call Forward on Busy (CFB)—implemented on Norstar 
Call Forward Busy.
• Call Forward on No Response (CFNR)—implemented on 
Norstar Call Forward No Answer.
Programming and restrictions
NCD features are accessed through existing Norstar features. 
Extensions requiring redirection must be programmed 
individually to either CFAC or SLR. CFB or CFNA must be 
set during programming. Allow redirect must be set to Yes 
for each extension, in...

Page 470

470 / Network Services
Modular ICS 6.1 Installer GuideP0603534  02
Diversion by SLR takes precedence over diversion by CFAC. 
An SLR line cannot be diverted by CFAC. If the call arrives 
on an extension with SLR programmed, a ring splash will 
sound (if programmed).
For information on SLR restrictions refer to Malicious call 
identification (MCID) on page 471. For information on 
redirecting lines see Line Redirection in the Modular ICS 
System Coordinator Guide.
Programming Extensions
The User Interface...