Nortel Modular Ics 6.1 Installer Guide
Here you can view all the pages of manual Nortel Modular Ics 6.1 Installer Guide. The Nortel manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 501
Hardware / 501 P0603534 02Modular ICS 6.1 Installer Guide D-packet servce 1. Press ≠ to view and program D-packet service for T or NT loops. You can have two D-packet service configurations for each BRI card. 2. Press CHANGE to turn D-packet service for this loop on (Y) or off (N). Lp 1. Select the S loop (for BRI-S/T cards) or LT loop for BRI-U2 or BRI-U4 cards that supports the D-packet service. 2. Press C H AN G E to move through a list of the loops which are available on this card. Note: If...
Page 502
502 / Hardware Modular ICS 6.1 Installer GuideP0603534 02 TEIs Press ≠ to view and program the Terminal Endpoint Identifiers (TEIs). Each TEI is supplied by your service provider and is associated with an ISDN D-channel packet device. No TEIs on loop Press ADD to program up to eight TEIs to this loop. Sampling Press CHANGE to select the sampling used by an S loop: •Fixed — select if two or more S-interface devices use the loop and the length of the loop is less than 200 m (650 ft.). •Adaptve —...
Page 503
Hardware / 503 P0603534 02Modular ICS 6.1 Installer Guide DNs on LoopInstaller password required Press ≠ to view and program the ISDN DNs assigned to the loop. Assign DNs 1. Press ≠ and enter the ISDN DN you wish to assign to this loop, or press SCAN to move through a list of DNs already assigned to the loop. The display shows: •Availabl, Assigned — assigned to this loop •*Lpnnn* — assigned as the default DN of another loop •Lpnnn — assigned to another loop 2. Press LIST to view the DNs assigned...
Page 504
504 / Hardware Modular ICS 6.1 Installer GuideP0603534 02 Clock SrcInstaller password required Systems with digital interfaces need to synchronize to the network in order to function. Synchronization is performed in a hierarchical way, where each device/switch obtains the network clock from the device/or switch above it in the synchronization hierarchy and passes the network clock to the device/switch below it in the synchronization hierarchy. The synchronization levels are referred to as strata....
Page 505
Hardware / 505 P0603534 02Modular ICS 6.1 Installer Guide The following illustrations show some typical network configuration and the appropriate clock source settings for your DTIs. Tips - If a BRI card becomes clock source, it will have up to four clock sources available (T, S, U-NT, NT loops only). Only when all four clock sources have an alarm will the card cause a switch to the secondary or hold-over state. BRI -T, S, and U-NT interface loops may be autonomously powered down by the network....
Page 506
506 / Hardware Modular ICS 6.1 Installer GuideP0603534 02 Norstar connected directly to the service provider in a T1 network Norstar connected to another switch or MUX in a T1 or PRI network Primary - DTI 1 obtains the timing from the service provider Secondary - DT12 acts as a standby to obtain the timing from the service provider Norstar ICS T1 or PRI service provider Norstar ICS Primary - DTI 1 obtains the timing from the network Secondary - DTI 2 acts as a standby to obtain the timing from the...
Page 507
Hardware / 507 P0603534 02Modular ICS 6.1 Installer Guide Norstar connected to another switch in a closed T1 or PRI network Norstar connected in a series of switches in a T1 or PRI network T1 or PRI service provider Norstar ICS Norstar or other switch Primar y - DTI 1 obtains the timing from the T1 service provider Secondary - DTI 2 acts as standby to obtain timing from the networkSecondary - DTI 2 acts as standby to obtain timing from the networkPrimary - DTI 1 obtains the timing from the T1...
Page 508
508 / Hardware Modular ICS 6.1 Installer GuideP0603534 02 Norstar connected by a T1 link to another switch in an analog network Setting the clock source for DTIs and PRI Start with the display showing Hardware. 1. Press ≠. 2. Press ‘. The display shows Cards on KSU. 3. Press ≠. 4. Press ‘ until the display shows the card you want to view. Changing clock source may disconnect calls. Changing the clock source for your system may cause your system to restart itself, resulting in dropped calls. Choose...
Page 509
Hardware / 509 P0603534 02Modular ICS 6.1 Installer Guide 5. Press ≠. 6. Press ‘ until the display shows ClockSrc. 7. Press CHANGE to toggle the setting. 8. Press ® to exit or ‘ to continue in Hardware. T1 or ISDN-PRI configurations The following tables indicate proper and improper T1 or ISDN-PRI configurations: Valid digital trunk configurations Tips - In most T1 network configurations, you need one DTI or DTI card configured as PRI in your ICS to act as a primary reference. The only application...
Page 510
510 / Hardware Modular ICS 6.1 Installer GuideP0603534 02 Invalid digital trunk configuration Valid mixed trunking configuration Invalid mixed trunking configuration Invalid configurations will raise an alarm. In these invalid configurations, digital links are likely to suffer errors, slips, etc. DataModInstaller password required Mod XX:DataMod DataMod allows you to configure the settings for any data modules you may have on your system. Type The display shows the type of data module selected....