Nortel Modular Ics 6.1 Installer Guide
Here you can view all the pages of manual Nortel Modular Ics 6.1 Installer Guide. The Nortel manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 531
Network evt log / 531 P0603534 02Modular ICS 6.1 Installer Guide Network evt log The Network evt log keeps a record of events and alarms that are specific to the T1 network interface. You can: • check the items in the log • erase the log • check when each item in the log occurred The Network evt log holds a maximum of 20 items. Erase the log after dealing with all the items. Checking the items in the logInstaller password required Start with Sys admin log on the display: 1. Press ‘. Network evt log...
Page 532
532 / Network evt log Modular ICS 6.1 Installer GuideP0603534 02 Erasing the log Start with Items in log: on the display. 1. Press ERASE . The display shows Erase log?. 2. Press YES . If no new items have been added since the list was entered, the display shows Log erased. If new items have been added since the list was entered, the display briefly reads Cancld-new items and returns to the display Items in log:. 3. Press – to return to Network evt log. Checking when each item in the log occurred...
Page 533
Alarm codes / 533 P0603534 02Modular ICS 6.1 Installer Guide Alarm codes The Norstar ICS system generates alarm codes after system disconnections or after certain anomalies in system operation. All alarm codes appear at the Alarm telephone and in the System test log of a Maintenance session. For a more complete description of alarm and event codes, consult your technical support representative. The following figure shows an alarm code appearing on a Norstar Alarm telephone display. Tips - The...
Page 534
534 / Alarm codes Modular ICS 6.1 Installer GuideP0603534 02 If you see an alarm code 1. Write the alarm code on the Sys test log record. 2. Determine the cause of the alarm from the following table. 3. Follow Alarm troubleshooting on page 537. 4. Press TIME to see when the alarm occurred. 5. Press CLEAR to clear the alarm. An alarm code may not be displayed until two minutes after it has been triggered. If the ICS is powered off when the alarm is triggered, the alarm code is not displayed until two...
Page 535
Alarm codes / 535 P0603534 02Modular ICS 6.1 Installer Guide Alarm: 37 ABBC DD An error has occurred in the download of a protocol to a BRI Card. A: the maintenance index of the BRI BB: a code describing the nature of the error C: the current download state DD (appears when the error is limited to one protocol): the two- character product identifier of the protocolThe BRI Card is not properly installed. Alarm: 40 Alarm: 41 Alarm: 42 Alarm: 43 Alarm: 44 Alarm: 45 Alarm: 46 Alarm: 47There is...
Page 536
536 / Alarm codes Modular ICS 6.1 Installer GuideP0603534 02 X = DS-30 port numbers, Y = Trunk Cartridge number (numbered from left to right), and Z = Trunk port number Alarm: 52 X YTC disconnected from TM Trunk Cartridge Y on DS-30 port X is disconnected from the TM. Alarm: 61 X YIncompatible Trunk CartridgeTrunk Cartridge Y on DS-30 port X cannot operate with the Trunk type assigned to it in Configuration. Alarm: 62 X YUnsupported Auto-answer setting (Loop Start TCs)Trunk Cartridge X on...
Page 537
Alarm codes / 537 P0603534 02Modular ICS 6.1 Installer Guide Alarm troubleshooting Refer to the previous table before following these procedures. Alarm: 10 1. Check to see if there is a device connected to the ICS (that has a port number beginning with the number 1). 2. If there are no devices connected to the ICS, connect one and then press CLEAR . 3. If there are any devices connected to the ICS, check all the wiring associated with the devices. 4. Refer to Problems with BRI service on page 600....
Page 538
538 / Alarm codes Modular ICS 6.1 Installer GuideP0603534 02 Alarm: 50-X 1. Check that there is a device connected to the Station Module, which has a port number beginning with a number from three to eight. 2. If there are no devices connected to the Station Module, connect one and then press CLEAR . 3. If there are any devices connected to the Station Module, check all the wiring associated with the devices. 4. Refer to Data Module down on page 605. Alarm: 51-X 1. Check the wiring from the ICS to...
Page 539
Alarm codes / 539 P0603534 02Modular ICS 6.1 Installer Guide Check that the Trunk mode and Answer mode settings do not conflict for every line connected to Trunk Cartridge Y. If Trunk mode is set to unsupervised, Answer mode must be set to manual. OR Install a Trunk Cartridge in slot Y that matches the type of trunk you have configured. Alarm: 62-X-Y 1. Check that the proper Trunk Cartridges are inserted in the proper slots of the Trunk Module. 2. Enter programming and look under the Trk/Line data...
Page 540
540 / Alarm codes Modular ICS 6.1 Installer GuideP0603534 02 4. If the problem persists, an E&M Trunk Cartridge may be malfunctioning. Replace one E&M Trunk Cartridge at a time until the problem is resolved. Alarm 68-Z 1. Locate the device(s) connected to port(s) not available for that device type. 2. Power down the system. 3. Disconnect the device from the port identified. 4. Reconnect it to a valid port. Alarm 75 1. Check the connection to your ISDN service provider. Alarm: 76-X 1. Check the...