Page 541
Event messages / 541 P0603534 02Modular ICS 6.1 Installer Guide Event messages Event messages appear as items in the System administration log or the System test log of the Maintenance session. Most of these event messages can only be caused by an unusual combination of events, and should rarely occur. Each event is assigned a severity number. An S preceding this number, S4 for example, may appear in the event message. S9 is the most severe. If the log is full, new event messages with a higher...
Page 542
542 / Event messages Modular ICS 6.1 Installer GuideP0603534 02 Significant event messages The following table lists event messages that are relevant to Maintenance activities. The time that the message is recorded is also provided. Displays Event messageThe event message is recorded when… Evt:210-YYYZ S4Loopback test YYY on Trunk Cartridge Z has started Evt:211-YYYZ S4Loopback test YYY on Trunk Cartridge Z has stopped Evt:220-3546 S4the Sys admin log has been cleared by the DN (3546 in this...
Page 543
Event messages / 543 P0603534 02Modular ICS 6.1 Installer Guide Evt:269-3546 S8the Line/set filter for the DN (3546 in this case) has lost data due to a fault in the system memory Evt:299 S1the system powers up after a power failure Evt:327 S5short term alarm threshold has been surpassed in the DTI cartridge Evt:328 S5short term alarm threshold has been surpassed in the DTI cartridge Evt:329 S5short term alarm threshold has been surpassed in the DTI cartridge Evt:330 S5short term alarm threshold...
Page 544
544 / Event messages Modular ICS 6.1 Installer GuideP0603534 02 Evt:422-3546 S6a length change by the DN (3546 in this case) has been requested Evt:423-3546 S6an individual DN change has been requested by the DN (3546 in this case) Evt:441 S2a timeout occurred while waiting for ANI or DNIS digits to be received Evt:442 S5a timeout occurred while waiting for ANI or DNIS digits to be received Evt:453 S4Someone entering **CONFIG Evt:454 S5Invalid password entered Evt:458 S4Call-by-Call NVRAM data...
Page 545
Event messages / 545 P0603534 02Modular ICS 6.1 Installer Guide Event message 799 Event message 799 indicates a call processing error has occurred on an ISDN line. The event number is followed by a number representing the line or loop number, and a code for the type of error. Evt:698 S8incorrect software key entered EVT799-00040B S7a call processing error on the fourth BRI loop; see Event message 799 on page 545. Evt:822 S8Alarm code 63 is sent because there are no DTMF receivers for an...
Page 546
546 / Event messages Modular ICS 6.1 Installer GuideP0603534 02 Displays You should rarely see any event messages that are not described in the Significant event messages on page 542. If you do see one of these event messages, the Norstar system has followed its normal recovery from an unusual combination of system events. Although the problem is not a serious one, repeated occurrences of the event number should be reported as soon as possible. As a result of some events, the Norstar system...
Page 547
Event messages / 547 P0603534 02Modular ICS 6.1 Installer Guide Most of these events are recorded in the Sys test log. The few exceptions to this are recorded in the Sys admin log, as indicated. Event MessageSystem RestartEvent MessageSystem Restart 101-106Ye s400 (Admin log)Ye s 107No401-403No 108-112Ye s405-411No 113No412-419 (Admin log)No 114-116Ye s421-423 (Admin log)No 117No424-425No 118-120Ye s426-430Ye s 121-123No431No 124-125Ye s432Ye s 126-129No433No 130Ye s441-442No 131-132No453No...
Page 548
548 / Event messages Modular ICS 6.1 Installer GuideP0603534 02 224Ye s799No 225-228No800-802No 229 (Admin log)No803Ye s 230-235No804-807No 245-248Ye s808Ye s 250-256No809No 260-271Ye s810Ye s 280-283No811-820No 285-298Ye s823Ye s 299No824-825No 327No851No 328No882No 329No883No 330No900No 336No940-943No 373No950-989No Event MessageSystem RestartEvent MessageSystem Restart
Page 549
Provisioning BRI and PRI lines / 549 P0603534 02Modular ICS 6.1 Installer Guide Provisioning BRI and PRI lines This section discusses how you put BRI and PRI lines into and out of service. BRI and T1 linesInstaller password required Provisioning applies to BRI and T1 loops and lines. It allows you to place loops and lines in or out of service, either before or after the BRI Cards have been installed in the ICS. When you provision a loop, ISDN terminals on the loop can be used to make outgoing calls...
Page 550
550 / Provisioning BRI and PRI lines Modular ICS 6.1 Installer GuideP0603534 02 L001 If the loop is configured as a U-NT, T or S loop, press ≠ and ‘ to display the individual lines. There are no lines associated with an S or U-LT loop. 1. Press REMOVE to take the line out of service. 2. If line is busy, the display will ask if you still want to remove it from service. Press YES to go ahead. Provisioning a T1 line Start with the display showing Network evt log. 1. Press ‘. Provisioning displays. 2....