Page 541

Event messages / 541
P0603534  02Modular ICS 6.1 Installer Guide
Event messages
Event messages appear as items in the System administration 
log or the System test log of the Maintenance session. Most of 
these event messages can only be caused by an unusual 
combination of events, and should rarely occur. 
Each event is assigned a severity number. An S preceding this 
number, S4 for example, may appear in the event message. 
S9 is the most severe. If the log is full, new event messages 
with a higher...

Page 542

542 / Event messages
Modular ICS 6.1 Installer GuideP0603534  02
Significant event messages 
The following table lists event messages that are relevant to 
Maintenance activities. The time that the message is recorded 
is also provided.
Displays
Event messageThe event message is recorded when…
Evt:210-YYYZ S4Loopback test YYY on Trunk Cartridge Z has 
started
Evt:211-YYYZ S4Loopback test YYY on Trunk Cartridge Z has 
stopped
Evt:220-3546  S4the Sys admin log has been cleared by the DN 
(3546 in this...

Page 543

Event messages / 543
P0603534  02Modular ICS 6.1 Installer Guide
Evt:269-3546 S8the Line/set filter for the DN (3546 in this case) has 
lost data due to a fault in the system memory
Evt:299 S1the system powers up after a power failure
Evt:327 S5short term alarm threshold has been surpassed in 
the DTI cartridge
Evt:328  S5short term alarm threshold has been surpassed in 
the DTI cartridge
Evt:329  S5short term alarm threshold has been surpassed in 
the DTI cartridge
Evt:330  S5short term alarm threshold...

Page 544

544 / Event messages
Modular ICS 6.1 Installer GuideP0603534  02
Evt:422-3546 S6a length change by the DN (3546 in this case) has 
been requested
Evt:423-3546 S6an individual DN change has been requested by the 
DN (3546 in this case)
Evt:441  S2a timeout occurred while waiting for ANI or DNIS 
digits to be received
Evt:442  S5a timeout occurred while waiting for ANI or DNIS 
digits to be received
Evt:453  S4Someone entering **CONFIG
Evt:454  S5Invalid password entered
Evt:458   S4Call-by-Call NVRAM data...

Page 545

Event messages / 545
P0603534  02Modular ICS 6.1 Installer Guide
Event message 799
Event message 799 indicates a call processing error has 
occurred on an ISDN line. The event number is followed by a 
number representing the line or loop number, and a code for 
the type of error. 
Evt:698  S8incorrect software key entered
EVT799-00040B
  S7a call processing error on the fourth BRI loop; see 
Event message 799 on page 545.
Evt:822  S8Alarm code 63 is sent because there are no DTMF 
receivers for an...

Page 546

546 / Event messages
Modular ICS 6.1 Installer GuideP0603534  02
Displays
You should rarely see any event messages that are not 
described in the Significant event messages on page 542. If 
you do see one of these event messages, the Norstar system has 
followed its normal recovery from an unusual combination of 
system events. Although the problem is not a serious one, 
repeated occurrences of the event number should be reported 
as soon as possible.
As a result of some events, the Norstar system...

Page 547

Event messages / 547
P0603534  02Modular ICS 6.1 Installer Guide
Most of these events are recorded in the Sys test log. The few 
exceptions to this are recorded in the Sys admin log, as 
indicated.
Event
MessageSystem 
RestartEvent 
MessageSystem 
Restart
101-106Ye s400 (Admin log)Ye s
107No401-403No
108-112Ye s405-411No
113No412-419 (Admin log)No
114-116Ye s421-423 (Admin log)No
117No424-425No
118-120Ye s426-430Ye s
121-123No431No
124-125Ye s432Ye s
126-129No433No
130Ye s441-442No
131-132No453No...

Page 548

548 / Event messages
Modular ICS 6.1 Installer GuideP0603534  02
224Ye s799No
225-228No800-802No
229 (Admin log)No803Ye s
230-235No804-807No
245-248Ye s808Ye s
250-256No809No
260-271Ye s810Ye s
280-283No811-820No
285-298Ye s823Ye s
299No824-825No
327No851No
328No882No
329No883No
330No900No
336No940-943No
373No950-989No
Event
MessageSystem 
RestartEvent 
MessageSystem 
Restart 

Page 549

Provisioning BRI and PRI lines / 549
P0603534  02Modular ICS 6.1 Installer Guide
Provisioning BRI and PRI lines
This section discusses how you put BRI and PRI lines into and 
out of service.
BRI and T1 linesInstaller password required
Provisioning applies to BRI and T1 loops and lines. It allows 
you to place loops and lines in or out of service, either before 
or after the BRI Cards have been installed in the ICS.
When you provision a loop, ISDN terminals on the loop can be 
used to make outgoing calls...

Page 550

550 / Provisioning BRI and PRI lines
Modular ICS 6.1 Installer GuideP0603534  02
L001
If the loop is configured as a U-NT, T or S loop, press 
≠ and  ‘ to display the individual lines. 
There are no lines associated with an S or U-LT loop.
1. Press REMOVE
 to take the line out of service.
2. If line is busy, the display will ask if you still want to 
remove it from service. Press YES
 to go ahead.
Provisioning a T1 line
Start with the display showing Network evt log.