Page 471

Network Services / 471
P0603534  02Modular ICS 6.1 Installer Guide
Note:  When Norstar requests that an incoming call be 
redirected by the distance network, Norstar does not 
inform the network of the redirecting DN. In this case, 
the diverted-to party will not see the diverting party 
DN.
Malicious call identification (MCID)
The MCID feature allows the user to press ≤°·‡ to 
have call information recorded on the central office system for 
an incoming call on a specific line (ETSI PRI lines, only).
The...

Page 472

472 / Network Services
Modular ICS 6.1 Installer GuideP0603534  02
MCDN services (profiles 1, 2, 4)Installer password required
If your system is part of a private network using PRI SL-1 
lines, you can determine the MCDN features that will be 
allowed by your system. These settings are described in detail 
in the networking section of this book. Refer to MCDN trunk 
call features on page 141.
• TRO: Trunk Route Optimization
• ICCL: ISDN Call Connection Limitation
• TAT: Trunk Anti-Tromboning
To program...

Page 473

Network Services / 473
P0603534  02Modular ICS 6.1 Installer Guide
Note:  If you set NetwkICCL to yes, check the Max transits 
settings under Hardware to confirm the threshold at 
which you want the system to release the call rather 
than to continue cycling. Refer to “Max transits” on 
page 492. 

Page 474

474 / Telco features
Modular ICS 6.1 Installer GuideP0603534  02
Telco features
Currently the two features accessed under this heading are the 
settings for the voice mail connections for your system, and 
how to set up outgoing name and number blocking (ONN).
With the display showing System prgming press ‘ 
until the display shows Telco features.
VMsg ctr tel#s
If you subscribe to a voice message service outside of your 
local system, you can access it through your Norstar system. 
This includes...

Page 475

Telco features / 475
P0603534  02Modular ICS 6.1 Installer Guide
6. Press CHANGE and enter the telephone number for the voice 
message system.
7. Press – to move up a level.
8. Press ‘ to move to the next Voice message 
center.
9. Repeat steps 3 to 8 for however many voice message 
centers you want to enter.
Outgoing Name and Number Blocking
Outgoing Name and Number blocking blocks the outgoing 
name and number on a per call basis when the user presses 
≤°⁄·
ONN blocking is cancelled with ≤£°⁄·
When this...

Page 476

476 / Telco features
Modular ICS 6.1 Installer GuideP0603534  02
Programming the analog vertical service code (VSC)
1. Press ≠. Analog VSC displays.
2. Press ≠. Tone:None displays.
3. Press CHANGE
 to enter a new tone dialing Name and 
Number blocking VSC. 
The VSC for tone trunks can include a maximum of 
10 digits consisting of the CO Pause (≤‡°), and 
digits 0-9, *, and #.
4. Press ‘. Pulse:None displays.
5. Press CHANGE
 to enter a new pulse dialing Name and 
Number blocking VSC. 
The VSC for pulse...

Page 477

Telco features / 477
P0603534  02Modular ICS 6.1 Installer Guide
Setting up the modules for ONN blocking
To utilize ONN blocking, the CO is alerted by two methods, 
either the Vertical Service Code (VSC) or the suppression bit 
method. Each method depends on the type of trunk involved in 
placing the outgoing call. 
Analog trunks use a dialing digit sequence called VSC. Most 
COs use the suppression bit method for ONN. You will need 
to use the VSC ONN if your CO does not support the 
suppression bit...

Page 478

478 / Telco features
Modular ICS 6.1 Installer GuideP0603534  02
Program ONN blocking BRI loop state
The display shows the loops found on the BRI card.
1. Press ‘ to display the settings for individual 
loops on a BRI card.
2. At the Loops display, press next to display the first loop 
number.
3. Press ≠. Type:T displays.
4. Press ‘ until ONNblk:SuprsBit displays.
5. Press CHANGE
 to toggle the BRI loop state setting from 
SuperBit to SrvcCode.
6. Repeat these steps to program ONN blocking BRI loop...

Page 479

Software keys / 479
P0603534  02Modular ICS 6.1 Installer Guide
Software keys
Some of the MICS system features require special pass codes, 
called software keys, to make the feature work. This section 
describes each of these options. To obtain the required 
Software key, call the Integrated Voice Response (IVR) 
Center at: 1-800-4NORTEL (667835), then use Express 
Routing Code 1599.
ISDN-PRI
A software key is required so that you can configure a DTI 
card as a PRI card for Profiles 1, 3 and 4.
Not PRI...

Page 480

480 / Software keys
Modular ICS 6.1 Installer GuideP0603534  02
System Identification Number
Obtain the System ID (SysID) by pressing 
≤••ÍÁÍÈÎ, or ≤••‡·‡›‹ 
on any system programming telephone.
This information is also available by accessing 
Software keys in an Installer programming session:
1. Press ≠ The display reads SysID: followed by 
the unique System Identification Number.
2. Press ‘ to continue in Software keys or 
® to exit.
3. Record the SysID in the Modular ICS Programming 
Record.
Call the...