Page 431

System prgrming / 431
P0603534  02Modular ICS 6.1 Installer Guide
The Invoke by Hold setting determines if a SWCA call put on 
Hold can be picked up from other extensions in the group. 
• If you want the call to be available to be picked up by other 
members of the groups when you put a call on Hold, set 
Invoke by Hold: to Y. A flashing indicator appears beside 
the SWCA key when the call assigned to that key is put on 
Hold. 
• If you want calls to remain on Hold only at the telephone 
where the call...

Page 432

432 / System prgrming
Modular ICS 6.1 Installer GuideP0603534  02
CLID match
This setting determines the minimum number of digits that an 
external call must match to an existing system speed dial 
number in order for the system to offer a name display for the 
CLID prompt, if the system speed dial number is set up to 
display the caller name. 
1. Under Featr settings, press ≠. 
The display shows Backgrnd music:.
2. Press ‘ until the display shows CLID match: 8.
3. Press CHANGE
 to select the a number...

Page 433

System prgrming / 433
P0603534  02Modular ICS 6.1 Installer Guide
You have the choice of silently monitoring the conversation, 
or providing a tone to the other two parties to indicate that the 
line is being monitored. This setting is the same for all 
supervisor telephones. Refer to the process below to determine 
the setting.
1. Under Featr settings, press ≠. The display 
shows Backgrnd music: N.
2. Press ‘ until the display shows Silent 
Monitor: Y.
3. Press CHANGE
 to select Y or N.
4. Press ® to...

Page 434

434 / System prgrming
Modular ICS 6.1 Installer GuideP0603534  02
Use ≠ and CHANGE to select the setting: Intrnl, 
Extrnl, or None.
Intrnl/Extrnl#
Enter the internal or external number that the system will 
automatically dial when someone enters the direct-dial digit.
Use ≠, CHANGE
, and the dialpad to enter the 
telephone number. 
The default number for the direct-dial telephone is 221, on the 
default three-digit DN system.
Line selection
If you assign an external number as a direct-dial telephone,...

Page 435

System prgrming / 435
P0603534  02Modular ICS 6.1 Installer Guide
CAP/KIM assignInstaller password required
This setting designates a telephone as a central answering 
position (CAP). A maximum of five designated CAPs can be 
installed in a Modular ICS system. The system can support 
more CAP configurations that are not designated in 
programming as CAPs. Refer to the Tips below for 
information about the difference between OKIMs and eKIMs.
CAPs can be configured as:
• M7324 telephones with attached CAP...

Page 436

436 / System prgrming
Modular ICS 6.1 Installer GuideP0603534  02
Dialing PlanInstaller password required
The dialing plan acts as a system directive that determines how 
a number will be dialed out by the system. This feature works 
with enbloc dialing, and, therefore, is only used for PRI lines.
The Dialing Plan has these features:
• allows public or private routing for network calls
• private routing allows the choice of either the uniform 
dialing plan (UDP) or a coordinated dialing plan (CDP)
•...

Page 437

System prgrming / 437
P0603534  02Modular ICS 6.1 Installer Guide
where you require a break in a dialing sequence to wait for 
a PRI line-generated dialtone.
• provides the ability to map user-dialed digits to a service 
type on a Call by Call basis
• allows incoming calls to be routed according to the service 
type and the digits received
DN lengths (enbloc dialing)
The Private DN Length must be set to the number of digits 
users dial to reach other nodes in a private network. The 
Private DN Length...

Page 438

438 / System prgrming
Modular ICS 6.1 Installer GuideP0603534  02
Private networks
Private network: None
Choosing this setting turns off MICS private network 
functionality.
1. At Type:None, press ‘. 
Priv DN len:4 displays.
2. Press CHANGE
 to choose a new private DN length. (3-14)
Private network: CDP
If your dialing plan needs to use steering codes to navigate to 
other networks, specify a coordinated dialing plan (CDP).
1. At Type:None, press CHANGE 
until CDP displays.
2. Press ‘. PrivNetID:1...

Page 439

System prgrming / 439
P0603534  02Modular ICS 6.1 Installer Guide
Private network: UDP
If your dialing plan will be using Location codes to navigate to 
other systems, specify a uniform dialing plan (UDP).
1. At Type:None, press CHANGE
 until UDP displays.
2. Press ‘. PrivNetID:1 displays.
3. Press CHANGE
, and enter a new private network id.
4. Press ‘. Loc code:None displays.
5. Press CHANGE
 and use the dialpad to enter a location code.
Note:  This code must be unique to your system.
6. Press ‘. Priv...

Page 440

440 / System prgrming
Modular ICS 6.1 Installer GuideP0603534  02
5. Press OK to accept the prefix.
6. Repeat steps 4 and 5 until all the prefixes have been added.
Dial Timeout
Dial Timeout (interdigit timeout) specifies how long the ICS 
will wait between user-dialed digits. This value allows the ICS 
to determine when the user has stopped dialing. The value is 
programmed under System progrming, Dialing Plan.
The user can also use the # key to tell the ICS that they are 
finished dialing. However, this...
Start reading Nortel Modular Ics 6.1 Installer Guide