Page 511

Programming (Cont’d)
➣
(384i Only) 0005 - Extension Circuit Type
Assign circuit type 2 for keysets with DCI.  Assign circuit type 4 for 3DCI module.
➣0007 - System Report Port Setup
If the SMDR printer will also be used for system reports, enter the SMDR DCI software port number as
the system report port number.
➣0008 - Alarm Report Port Setup
If the SMDR printer will also be used for alarm reports, enter the SMDR DCI software port number as
the alarm report port number.
➣0130 - Date Format for SMDR and...

Page 512

Programming (Cont’d)
➣
1201 - DCI Setup, Type 1, Item 1, Register 65
Set the DCI communications parameters to match the SMDR device.
➣1202 - DCI Port Type
Set this option to 1 if SMDR device is serial. Set this option to 2 if SMDR device is Centronics parallel.
➣1206 - Initialize DCI
Initialize the DCI port selected for SMDR.
Related Features
PBX Compatibility
To use the PBX Call Reporting option, program system for behind PBX operation.
Traffic Management Report (TMS)
Traffic Management Reports and SMDR...

Page 513

T1 Trunking (with ANI/DNIS Compatibility)
Description
 124i Available — Basic T1 capabilities
require EXCPRU version 2.18 or
higher. T1 DID and tie lines require
a DTDU PCB. 384i Available — Customizing the CODEC
Gain Types requires system software
3.04 or higher. 
- ANI/DNIS Compatibility requires
EXCPRU 2.18 or higher. It is not
available in Base software.- ANI/DNIS Compatibility requires
system software 3.06.02 or higher.
- ANI/DNIS routing to the VAU
Automated Attendant  requires
EXCPRU 4.02 or...

Page 514

Description (Cont’d)
ANI/DNIS Compatibility
The system is compatible with telco’s T1 Automatic Number Identification (ANI) and Dialed Number Informa-
tion Service (DNIS) services. A complement to Caller ID service, ANI/DNIS Compatibility provides:
•Selectable Receive Format
You can set up the system for compatibility with any combination of ANI, DNIS and Dialed Number
(Address) data provided by the telco.
•Flexible Routing
Based on the data received, the system can route the incoming ANI/DNIS call to:
–...

Page 515

Programming
Start
Are the T1 trunks
loop start or gound
start?In 2601, enter 0 for each
loop start trunk.In 2601, enter 1 for each
ground start trunk.
Should the T1/PRI
Interface PCB use
internal or external
(telco) clock?In 2602, enter 2 for
each PCB.
Loop startGround start
InternalExternal
Do the T1/PRI Interface
PCBs timing
parameters match the
requirements of the
telco?
In 0136, change the
T1 Trunk Timers.In 0136, do not
change the T1
Trunk Timers.
Go to 0009 Item 10 to
test T1 circuits.Yes
Check...

Page 516

Programming (Cont’d)
Additional Programming for ANI/DNIS
Continued
from
previous
page.
(384i Only)Are any DTMF
receivers reserved for
DTMF reception?IN 0303, reserve at least
one CDTU DTMF
receiver for DTMF
reception (entry 2).
In 0901:14-17, assign
service type 6 to all
ANI/DNIS T1 trunks.In 0905, group ANI/
DNIS trunks into Trunk
Groups as required.
Are the ANI/DNIS
Service Options
set up?In 2404, review the data
for each item and
configure the service
options (1-15).
In 0924, assign ANI/
DNIS Service...

Page 517

Programming (Cont’d)
ANI/DNIS Routing to the VAU Automated Attendant
Continued
from
previous
page.
Do you want to route to
the Automated Attendant
using the Caller ID Table,
the DID Table or directly?
Should VAU routing be
based on the number
dialed, or the number
dialed 
and the incoming
trunk used?
Caller ID
In the name portion of
2402, enter 882 + VAU
message (01-16).Number
Dialed
In the name
portion of 2402,
enter 127 (384i)
or 15 (124i).Number
Dialed &
Trunk
In 2205, enter the VAU
message (01-16)...

Page 518

Programming (Cont’d)
Continued
from
previous
page.
Do you want to route to
the Automated
Attendant using the DID
Table or directly?In 2205, enter the
VAU message (01-
16) for each trunk.
Directly
In 2404:3, enter 0
to bypass the
routing tables.
Should VAU routing be
based on the number
dialed, or the number
dialed and the incoming
trunk used?
DID Table
In the TRF portion of
1806, enter 882 + VAU
message (01-16).Number
DialedIn the TRF portion of
1806, enter 882 + VAU
message (01-16).Number
Dialed &...

Page 519

Programming (Cont’d)
➣
0009 - Loop Back Testing, Item 10: T1 Test
Once installed, use this program to test the T1 trunks.
➣0117 - Trunk CODEC Gain Type Settings
Customize the transmit and receive levels of the CODEC Gain Types assigned in 0901 Item 3.
➣0136 - T1 Trunk Timers
Set various T1 trunk timers for compatibility with the local telco. For ANI/DNIS, the following settings
in Program 0136 are recommended:
•Item 59: Clock Select = 2 (External - provided by Central Office)
•Item 60: Distance Between...

Page 520

Programming (Cont’d)
Program - 2404 ANI/DNIS Service Options
Option Description Range Default
Item 1ANI/DNIS Receive Format
Use this option to specify the format of the ANI/DNIS
data received from the telco. Make sure your entry is
compatible with the service the telco provides. (The
character * indicates a delimiter.)
0 = Address (called number without delimiters)
1 = *ANI*
1
2 = *DNIS*
3 = *ANI*Address*1
4 = *ANI*DNIS*1
5 = *DNIS*ANI*1
1
Select one of these options for Voice Mail Caller ID.0-5 0...