Page 511
Programming (Cont’d) ➣ (384i Only) 0005 - Extension Circuit Type Assign circuit type 2 for keysets with DCI. Assign circuit type 4 for 3DCI module. ➣0007 - System Report Port Setup If the SMDR printer will also be used for system reports, enter the SMDR DCI software port number as the system report port number. ➣0008 - Alarm Report Port Setup If the SMDR printer will also be used for alarm reports, enter the SMDR DCI software port number as the alarm report port number. ➣0130 - Date Format for SMDR and...
Page 512
Programming (Cont’d) ➣ 1201 - DCI Setup, Type 1, Item 1, Register 65 Set the DCI communications parameters to match the SMDR device. ➣1202 - DCI Port Type Set this option to 1 if SMDR device is serial. Set this option to 2 if SMDR device is Centronics parallel. ➣1206 - Initialize DCI Initialize the DCI port selected for SMDR. Related Features PBX Compatibility To use the PBX Call Reporting option, program system for behind PBX operation. Traffic Management Report (TMS) Traffic Management Reports and SMDR...
Page 513
T1 Trunking (with ANI/DNIS Compatibility) Description 124i Available — Basic T1 capabilities require EXCPRU version 2.18 or higher. T1 DID and tie lines require a DTDU PCB. 384i Available — Customizing the CODEC Gain Types requires system software 3.04 or higher. - ANI/DNIS Compatibility requires EXCPRU 2.18 or higher. It is not available in Base software.- ANI/DNIS Compatibility requires system software 3.06.02 or higher. - ANI/DNIS routing to the VAU Automated Attendant requires EXCPRU 4.02 or...
Page 514
Description (Cont’d) ANI/DNIS Compatibility The system is compatible with telco’s T1 Automatic Number Identification (ANI) and Dialed Number Informa- tion Service (DNIS) services. A complement to Caller ID service, ANI/DNIS Compatibility provides: •Selectable Receive Format You can set up the system for compatibility with any combination of ANI, DNIS and Dialed Number (Address) data provided by the telco. •Flexible Routing Based on the data received, the system can route the incoming ANI/DNIS call to: –...
Page 515
Programming Start Are the T1 trunks loop start or gound start?In 2601, enter 0 for each loop start trunk.In 2601, enter 1 for each ground start trunk. Should the T1/PRI Interface PCB use internal or external (telco) clock?In 2602, enter 2 for each PCB. Loop startGround start InternalExternal Do the T1/PRI Interface PCBs timing parameters match the requirements of the telco? In 0136, change the T1 Trunk Timers.In 0136, do not change the T1 Trunk Timers. Go to 0009 Item 10 to test T1 circuits.Yes Check...
Page 516
Programming (Cont’d) Additional Programming for ANI/DNIS Continued from previous page. (384i Only)Are any DTMF receivers reserved for DTMF reception?IN 0303, reserve at least one CDTU DTMF receiver for DTMF reception (entry 2). In 0901:14-17, assign service type 6 to all ANI/DNIS T1 trunks.In 0905, group ANI/ DNIS trunks into Trunk Groups as required. Are the ANI/DNIS Service Options set up?In 2404, review the data for each item and configure the service options (1-15). In 0924, assign ANI/ DNIS Service...
Page 517
Programming (Cont’d) ANI/DNIS Routing to the VAU Automated Attendant Continued from previous page. Do you want to route to the Automated Attendant using the Caller ID Table, the DID Table or directly? Should VAU routing be based on the number dialed, or the number dialed and the incoming trunk used? Caller ID In the name portion of 2402, enter 882 + VAU message (01-16).Number Dialed In the name portion of 2402, enter 127 (384i) or 15 (124i).Number Dialed & Trunk In 2205, enter the VAU message (01-16)...
Page 518
Programming (Cont’d) Continued from previous page. Do you want to route to the Automated Attendant using the DID Table or directly?In 2205, enter the VAU message (01- 16) for each trunk. Directly In 2404:3, enter 0 to bypass the routing tables. Should VAU routing be based on the number dialed, or the number dialed and the incoming trunk used? DID Table In the TRF portion of 1806, enter 882 + VAU message (01-16).Number DialedIn the TRF portion of 1806, enter 882 + VAU message (01-16).Number Dialed &...
Page 519
Programming (Cont’d) ➣ 0009 - Loop Back Testing, Item 10: T1 Test Once installed, use this program to test the T1 trunks. ➣0117 - Trunk CODEC Gain Type Settings Customize the transmit and receive levels of the CODEC Gain Types assigned in 0901 Item 3. ➣0136 - T1 Trunk Timers Set various T1 trunk timers for compatibility with the local telco. For ANI/DNIS, the following settings in Program 0136 are recommended: •Item 59: Clock Select = 2 (External - provided by Central Office) •Item 60: Distance Between...
Page 520
Programming (Cont’d) Program - 2404 ANI/DNIS Service Options Option Description Range Default Item 1ANI/DNIS Receive Format Use this option to specify the format of the ANI/DNIS data received from the telco. Make sure your entry is compatible with the service the telco provides. (The character * indicates a delimiter.) 0 = Address (called number without delimiters) 1 = *ANI* 1 2 = *DNIS* 3 = *ANI*Address*1 4 = *ANI*DNIS*1 5 = *DNIS*ANI*1 1 Select one of these options for Voice Mail Caller ID.0-5 0...