ND-45857 (E) CHAPTER 4 Page 89 Revision 3.0 SYSTEM DATA PROGRAMMING DESCRIPTION DATA • YY = 33 (Interval of ringing signal) (1) Trunk Route No. (00 – 63) (2) 0: 0.4s ON – 0.2s OFF – 0.4s ON–2s OFF 1: 0.4s ON – 0.2s OFF – 0.4s ON–2s OFF 2: 1s ON – 2s OFF 3 : When CM08 – 392 = 0: 2s ON – 4s OFF 3 : When CM08 – 392 = 1: 0.4s ON – 0.2s OFF – 0.4s ON – 2s OFF When the data for CM35 YY = 18 is set to 0, as- sign the data for converting the received digit.• Y = 0 (Day Mode) • Y = 1 (Night Mode) (1)...
Page 102
CHAPTER 4 ND-45857 (E) Pag e 9 0 Revision 3.0 SYSTEM DATA PROGRAMMING DESCRIPTION DATA Assign the answering method of the Automated Attendant to the required tenants.•Y = 0 (1) Tenant No. (00 – 63) (2) 00: DT Connection 02: 1st Answering Message followed by DT Connection 03 : DT Connection Assign the data of Hold Tone Sending. • Y = 0 (1) 00:C.O. Line (2) 1400: Hold Tone Source on MP Card If no Dial tone connection is required for the answering system assigned by CM64 Y = 0, set data “0”.•Y = 2 (1)...
Page 103
ND-45857 (E) CHAPTER 4 Page 91 Revision 3.0 SYSTEM DATA PROGRAMMING DESCRIPTION DATA Specify the Terminating System for called Par- ty Subaddress.(1) 401 (2) 0: Station Call 1 : Terminating System assigned by CM30 YY = 02, 03 Specify the time before an Automated Atten- dant call is redirected because no digits are re- ceived from the calling party.•Y = 0 (1) 34 (2) 01 – 30: 0 – 120 sec. If no data is set, the default setting is 32 – 36 seconds. Specify the timing of unanswered call after for- warding...
Page 104
CHAPTER 4 ND-45857 (E) Pag e 9 2 Revision 3.0 SYSTEM DATA PROGRAMMING When the 1st and/or 2nd answering message is required: CM30 YY=30, 31, Data=08/CM64 Y=0, Data=02, do the following programming. DESCRIPTION DATA Assign a Digital Announcement Trunk Circuit No. to the required LEN. Note:The Digital Announcement Trunk Circuit No. must be assigned to the 1st LEN (Lev- el 0) and/or 3rd LEN (Level 2) of each LT slot. (1) LEN (0000 – 0511) (2) EB000 – EB127: Digital Announcement Trunk Circuit No. EB000 –...
Page 105
ND-45857 (E) CHAPTER 4 Page 93 Revision 3.0 SYSTEM DATA PROGRAMMING 3.3.11 Direct Inward System Access (DISA) Assignment To provide the DISA without Application Processor (PN-AP01): DESCRIPTION DATA Designate the processor checking the ID code on DISA.(1) 217 (2) 0: MP (PN-CP00) Designate the Terminating System for Called Party Subaddress.(1) 401 (2) 0/1 : Station Call/Terminating System assigned by CM30 YY = 02/03 Assign the ring rate on a DISA call. (1) 180 (2) 0/1 : 0.2s ON – 0.2s OFF – 0.2s ON –...
Page 106
CHAPTER 4 ND-45857 (E) Pag e 9 4 Revision 3.0 SYSTEM DATA PROGRAMMING DESCRIPTION DATA Assign the handling of busy/not available/unan- swered Automated Attendant, DISA destina- tion in Day/Night Mode.• YY = 30 (Day mode) • YY = 31 (Night mode) (1) Trunk No. (000 – 255) (2) 00: C.O. Line Release 01: Forwarded to TAS 03: Forwarded to ATTCON 04: Forwarded to DIT Station assigned by CM30 Y = 04, 05. 06: DT Connection for redial 08: C.O. Line Release 15 : C.O. Line Release Assign the handling of...
Page 107
ND-45857 (E) CHAPTER 4 Page 95 Revision 3.0 SYSTEM DATA PROGRAMMING DESCRIPTION DATA Assign the data for digit conversion on DID call to the Route No. assigned by CM30 YY = 00 when providing DISA to the DID call.• YY = 18 (1) Trunk Route No. (00 – 63) (2) 0/1 : To be provided/Not to be provided When the data for CM35 YY = 18 is set to 0, as- sign the data for converting the received digit(s) to DISA.• Y = 0 (Day Mode) • Y = 1 (Night Mode) (1) X-XXXX:Station No. received (2) D16: DISA Assign the ID...
Page 108
CHAPTER 4 ND-45857 (E) Pag e 9 6 Revision 3.0 SYSTEM DATA PROGRAMMING DESCRIPTION DATA Specify the maximum number of digits for ID Code on DISA.(1) 13 (2) 01 – 16 (Number of digits) If no data is set, 10 digits of ID Code are avail- able.CM42 C END
Page 109
ND-45857 (E) CHAPTER 4 Page 97 Revision 3.0 SYSTEM DATA PROGRAMMING To provide the DISA with AP (PN-AP01): DESCRIPTION DATA Assign the slot number to the PN-AP01 card. The SENSE Switch on the PN-AP01 card should be set to the slot number assigned by this command. (1) Slot No. (04 – 15) (2) 07 Designate the processor checking the DISA ID Codes.(1) 217 (2) 1 : AP (PN-AP01) Designate the Terminating System for Called Party Subaddress.(1) 401 (2) 0/1 : Station Call/Terminating System assigned by CM30...
Page 110
CHAPTER 4 ND-45857 (E) Pag e 9 8 Revision 3.0 SYSTEM DATA PROGRAMMING DESCRIPTION DATA Assign the Trunk Tenant. • YY = 01 (1) Trunk No. (000 – 255) (2) Trunk Tenant (00 – 63) If no data is set, the default setting is 01. Assign the Terminating System in Day/Night Mode for incoming C.O. Calls.• YY = 02 (Day Mode) • YY = 03 (Night Mode) (1) Trunk No. (000 – 255) (2) 18:ISDN Indial Assign the handling of busy/not available/unan- swered Automated Attendant, DISA destina- tion in Day/Night Mode.• YY = 30...