ND-45504 (E) CHAPTER 4 Page 63 Revision 2.0 PN-BRTA (BRI) (2) Lamp Indications Lamp Indications on the PN-BRTA (BRI) Card LAMP NAME COLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally. B1 GreenB1 channel status ON: Busy OFF: Idle Flash (60 IPM):Make Busy B2 GreenB2 channel status ON: Busy OFF: Idle Flash (60 IPM):Make Busy DGreenD channel status ON: Busy OFF: Idle ALM RedTransmission line fault status ON: Line fault OFF: Normal operation
Page 72
CHAPTER 4 ND-45504 (E) Pag e 64 Revision 2.0 PN-BRTA (BRI) (3) Switch Settings The figure in the SWITCH NAME column and the position in in the SETTING POSITION col- umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. Note 1:Set the groove on the switch knob to the desired switch position. Note 2:When the power is on, set the MB switch to ON (UP position) before plugging/unplugging the...
Page 73
ND-45504 (E) CHAPTER 4 Page 65 Revision 2.0 PN-BRTA (BRI) Note 3: Set SW0-2 and SW0-3 as follows. BRI 0 BRI 1 BRI 2 .... BRI 11 REMARKS SW 0-2SW 0-3SW 0-2SW 0-3SW 0-2SW 0-3....SW 0-2SW 0-3 When one BRI is provided.ON ONThe MP card will receive the clock signal from BRI 0 at its PLO 0 input. When more than one BRI is pro- vided. ON ON ON OFF OFF ON .... OFF ONThe MP card will receive the clock signal from BRI 0 at its PLO 0 input under nor- mal conditions. Should a clock failure occur on BRI...
Page 74
PN-2BRTC (BRI) CHAPTER 4 ND-45504 (E) Page 65-1 Addendum-001 Revision 2.1 JULY, 1998 PN-2BRTC (BRI) 1. Locations of Lamps, Switches, and connectors PN-2BRTC (BRI) Card RU N SENS MB SW0 D1 ALM1 B20 B10 SW11SW10 D0 ALM0 B21 B11
Page 75
PN-2BRTC (BRI) ND-45504 (E) CHAPTER 4 Addendum-001 Page 65-2 JULY, 1998 Revision 2.1 2. Lamp Indications Lamp Indications LAMP NAME COLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally. B21 Red No.1 Circuit B2 channel status ON: Busy OFF: Idle Flash (60 IPM): Make Busy B11 Red B1 channel status ON: Busy OFF: Idle Flash (60 IPM): Make Busy D1 Green D channel status ON: Busy OFF: Idle ALM1 Red Transmission line fault status ON: Line fault OFF: Normal operation B20 Red No.0...
Page 76
PN-2BRTC (BRI) CHAPTER 4 ND-45504 (E) Page 65-3 Addendum-001 Revision 2.1 JULY, 1998 3. Switch Settings Switch Settings SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SENS (Rotary SW) Note 14 ~ F Set the switch to match the AP Number (04-15) as set by CM05. 0 ~ 3 Not used MB (Toggle SW) Note 2UP For make-busy For normal operation SW0, SW10 (Dip SW) 1For terminating the transmitting side of channels B1 and B2 with 100 ohms. OFFTo remove the terminating resistor on the transmitting side of...
Page 77
PN-2BRTC (BRI) ND-45504 (E) CHAPTER 4 Addendum-001 Page 65-4 JULY, 1998 Revision 2.1 The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. Note 1:Set the groove on the switch knob to the desired switch position. Note 2:When the power is on, set the MB switch to ON (UP position) before plugging/unplugging the...
Page 78
CHAPTER 4 ND-45504 (E) Pag e 66 Revision 2.0 PN-CC00 (ETHER) PN-CC00 (ETHER) 1. Locations of Lamps, Switches, and Connectors PN-CC00 (ETHER) Card ETHER RUN IP SW31 SW ERR S1 S2 S3RUN SW ERR S1 S2 S3 PN-CC00 PZ-M397 SW51
Page 79
ND-45504 (E) CHAPTER 4 Addendum-001 Page 67 JULY, 1998 Revision 2.1 PN-CC00 (ETHER) 2. Lamp Indications Lamp Indications LAMP NAME COLOR FUNCTION RUN Green Steadily lights while this card is operating normally. ERR Red Flashes at 120 IPM when system error occurs. S1 Green Lights when it is transmitting or receiving the data. S2 Green Lights when it can transmit or receive the data. S3 Green Lights when the power sets ON.
Page 80
CHAPTER 4 ND-45504 (E) Pag e 68 Revision 2.0 PN-CC00 (ETHER) (3) Switch Settings Note:Each equipment must have a unique MAC address to distinguish between systems. Therefore, when more than one PBX is installed in the same network, assign the lower 3 digits of the following MAC address by SW31 and SW51 to prevent duplicate addresses. Switch Settings SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SW (Rotary SW)0Always set to 0 1-FNot used SW51 (Dip SW) Note1 (D15) ON 2 (D14) ON 3 (D13) ON 4...