ND-45504 (E) CHAPTER 4
Page 63
Revision 2.0
PN-BRTA (BRI)
(2) Lamp Indications
Lamp Indications on the PN-BRTA (BRI) Card
LAMP NAME COLOR FUNCTION
RUN Green Flashes at 120 IPM while this card is operating normally.
B1 GreenB1 channel status
ON: Busy
OFF: Idle
Flash (60 IPM):Make Busy
B2 GreenB2 channel status
ON: Busy
OFF: Idle
Flash (60 IPM):Make Busy
DGreenD channel status
ON: Busy
OFF: Idle
ALM RedTransmission line fault status
ON: Line fault
OFF: Normal operation 

Page 72

CHAPTER 4 ND-45504 (E)
Pag e 64
Revision 2.0
PN-BRTA (BRI)
(3) Switch Settings
The figure in the SWITCH NAME column and the position in   in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
 , the setting of the switch varies with the system concerned.
Note 1:Set the groove on the switch knob to the desired switch position.
Note 2:When the power is on, set the MB switch to ON (UP position) before plugging/unplugging the...

Page 73

ND-45504 (E) CHAPTER 4
Page 65
Revision 2.0
PN-BRTA (BRI)
Note 3:
Set SW0-2 and SW0-3 as follows.
BRI 0 BRI 1 BRI 2 .... BRI 11
REMARKS
SW 
0-2SW 
0-3SW 
0-2SW 
0-3SW 
0-2SW 
0-3....SW 
0-2SW 
0-3
When one BRI is 
provided.ON ONThe MP card will receive the clock signal 
from BRI 0 at its PLO 0 input.
When more than 
one BRI is pro-
vided.
ON ON ON OFF OFF ON .... OFF ONThe MP card will receive the clock signal 
from BRI 0 at its PLO 0 input under nor-
mal conditions.
Should a clock failure occur on BRI...

Page 74

PN-2BRTC (BRI)
CHAPTER 4 ND-45504 (E)
Page 65-1 Addendum-001
Revision 2.1 JULY, 1998
PN-2BRTC (BRI)
1. Locations of Lamps, Switches, and connectors
PN-2BRTC (BRI) Card
RU N
SENS
MB
SW0
D1
ALM1
B20
B10
SW11SW10
D0
ALM0
B21
B11 

Page 75

PN-2BRTC (BRI)
ND-45504 (E) CHAPTER 4
Addendum-001 Page 65-2
JULY, 1998 Revision 2.1
2. Lamp Indications
Lamp Indications
LAMP NAME COLOR FUNCTION
RUN Green Flashes at 120 IPM while this card is operating normally.
B21 Red No.1 Circuit B2 channel status
ON: Busy
OFF: Idle
Flash (60 IPM):  Make Busy
B11 Red B1 channel status
ON: Busy
OFF: Idle
Flash (60 IPM):  Make Busy
D1 Green D channel status
ON: Busy
OFF: Idle
ALM1 Red Transmission line fault status
ON: Line fault
OFF: Normal operation
B20 Red No.0...

Page 76

PN-2BRTC (BRI)
CHAPTER 4 ND-45504 (E)
Page 65-3 Addendum-001
Revision 2.1 JULY, 1998
3. Switch Settings
Switch Settings
SWITCH NAMESWITCH 
NUMBERSETTING 
POSITIONFUNCTION CHECK
SENS
(Rotary SW)
Note 14 ~ F Set the switch to match the AP Number (04-15) as set by
CM05.
0 
~ 3 Not used
MB (Toggle SW)
Note 2UP For make-busy
For normal operation
SW0, SW10
(Dip SW)
1For terminating the transmitting side
of channels B1 and B2 with 100 ohms.
OFFTo remove the terminating resistor on
the transmitting side of...

Page 77

PN-2BRTC (BRI)
ND-45504 (E) CHAPTER 4
Addendum-001 Page 65-4
JULY, 1998 Revision 2.1
The figure in the SWITCH NAME column and the position in   in the SETTING POSITION
column indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
Note 1:Set the groove on the switch knob to the desired switch position.
Note 2:When the power is on, set the MB switch to ON (UP position) before plugging/unplugging the...

Page 78

CHAPTER 4 ND-45504 (E)
Pag e 66
Revision 2.0
PN-CC00 (ETHER)
PN-CC00 (ETHER)
1. Locations of Lamps, Switches, and Connectors
PN-CC00 (ETHER) Card
ETHER
RUN
IP
SW31
SW
ERR
S1
S2
S3RUN
SW
ERR
S1
S2
S3 PN-CC00 PZ-M397
SW51 

Page 79

ND-45504 (E) CHAPTER 4
Addendum-001 Page 67
JULY, 1998 Revision 2.1
PN-CC00 (ETHER)
2. Lamp Indications
Lamp Indications
LAMP NAME COLOR FUNCTION
RUN Green Steadily lights while this card is operating normally.
ERR Red Flashes at 120 IPM when system error occurs.
S1 Green Lights when it is transmitting or receiving the data.
S2 Green Lights when it can transmit or receive the data.
S3 Green Lights when the power sets ON. 

Page 80

CHAPTER 4 ND-45504 (E)
Pag e 68
Revision 2.0
PN-CC00 (ETHER)
(3) Switch Settings
Note:Each equipment must have a unique MAC address to distinguish between systems. Therefore, when more
than one PBX is installed in the same network, assign the lower 3 digits of the following MAC address by
SW31 and SW51 to prevent duplicate addresses. 
Switch Settings 
SWITCH
NAMESWITCH
NUMBERSETTING
POSITIONFUNCTION CHECK
SW
(Rotary SW)0Always set to 0
1-FNot used
SW51 (Dip SW)
Note1 (D15) ON
2 (D14) ON
3 (D13) ON
4...