Page 51

ND-45504 (E) CHAPTER 4
Page 43
Revision 2.0
PN-PW00 (EXTPWR)
(3) Switch Setting
The figure in the SWITCH NAME column and the position in   in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
Note:When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit card.
Switch Settings 
SWITCH
NAMESWITCH
NUMBERSETTING...

Page 52

CHAPTER 4 ND-45504 (E)
Pag e 44
Revision 2.0
PZ-PW86 (PWR)
PZ-PW86 (PWR)
1. Locations of Lamps, Switches, and Connectors
PZ-PW86 (PWR) Card
2. Lamp Indications
Lamp Indications
LAMP NAME COLOR FUNCTION
MJ Red Lights upon occurrence of a major trouble
MN Yellow Lights upon occurrence of a minor trouble
ON Green Remains lit while the operating power is being supplied
FRONT VIEW SIDE VIEWMJ
MN
ONMN MJ
ON
GND
–27V FG
GND
–27V FG
OFFON –
240 100/120 1
2 ON
SW102 

Page 53

ND-45504 (E) CHAPTER 4
Page 45
Revision 2.0
PZ-PW86 (PWR)
(3) Switch Settings
The figure in the SWITCH NAME column and the position in   in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
Switch Settings
SWITCH NAMESWITCH 
NUMBERSETTING
POSITIONFUNCTION CHECK
1Set to ON.
2ONStandard setting (for equalize charging)
OFFNot used
SW
ONFor turning AC source power on...

Page 54

CHAPTER 4 ND-45504 (E)
Pag e 46
Revision 2.0
PZ-PW86-A (PWR)
PZ-PW86-A (PWR)
1. Locations of Lamps, Switches, and Connectors
PZ-PW86-A (PWR) Card
2. Lamp Indications
Lamp Indications
LAMP NAME COLOR FUNCTION
MJ Red Lights upon occurrence of a major trouble
MN Yellow Lights upon occurrence of a minor trouble
ON Green Remains lit while the operating power is being supplied
FRONT VIEW SIDE VIEWMJ
MN
ONMN MJ
ON
GND
–27V FG
GND
–27V FG
OFFON –
240 100/120 1
2 ON
SW102SW102 

Page 55

ND-45504 (E) CHAPTER 4
Page 47
Revision 2.0
PZ-PW86-A (PWR)
(3) Switch Settings
The figure in the SWITCH NAME column and the position in   in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
Switch Settings
SWITCH NAMESWITCH 
NUMBERSETTING
POSITIONFUNCTION CHECK
SW102
PRESS 
MOMENTARILYTo start each PIM on battery power, when AC 
power is not provided (Switch “SW”...

Page 56

CHAPTER 4 ND-45504 (E)
Pag e 48
Revision 2.0
PZ-PW86 (C) (PWR)
PZ-PW86 (C) (PWR)
1. Locations of Lamps, Switches, and Connectors
PZ-PW86(C) (PWR) Card
2. Lamp Indications
Lamp Indications
LAMP NAME COLOR FUNCTION
MJ Red Lights upon occurrence of a major trouble
MN Orange Lights upon occurrence of a minor trouble
ON Green Remains lit while the operating power is being supplied
FRONT VIEW BATT2 MN MJ
ONBATTERY
SIDE VIEW GND
–27V FG
OFFON
240VAC 100/120VAC 2ON
2
1 ON SW102
START
SIG
1
SW1
BATT1
AC...

Page 57

ND-45504 (E) CHAPTER 4
Page 49
Revision 2.0
PZ-PW86 (C) (PWR)
(3) Switch Settings
The figure in the SWITCH NAME column and the position in    in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned. Switch Settings
SWITCH NAMESWITCH 
NUMBERSETTING 
POSITIONFUNCTION CHECK
MODE 1 Always set to OFF
2Float charging, for sealed batteries (Normal 
Setting).
OPTION: Periodic...

Page 58

CHAPTER 4 ND-45504 (E)
Pag e 50
Revision 2.0
PZ-PW86 (D) (PWR)
PZ-PW86 (D) (PWR)
1. Locations of Lamps, Switches, and Connectors
PZ-PW86(D) (PWR) Card
2. Lamp Indications
Lamp Indications
LAMP NAME COLOR FUNCTION
MJ Red Lights upon occurrence of a major trouble
MN Orange Lights upon occurrence of a minor trouble
ON Green Remains lit while the operating power is being supplied
FRONT VIEWBATT2 MN MJ
ON
BATTERY
SIDE VIEW GND
–27V FG
OFFON 240VAC 100/120VAC2ON
2
1 ON SW102
START
SIG
1
SW1 BATT1
AC INPUTMODE...

Page 59

ND-45504 (E) CHAPTER 4
Page 51
Revision 2.0
PZ-PW86 (D) (PWR)
(3) Switch Settings
The figure in the SWITCH NAME column and the position in    in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
Switch Settings
SWITCH NAMESWITCH 
NUMBERSETTING 
POSITIONFUNCTION CHECK
MODE 1 Always set to OFF
2Float charging, for sealed batteries (Normal 
Setting).
OPTION: Periodic...

Page 60

CHAPTER 4 ND-45504 (E)
Page 52 Addendum-001
Revision 2.1 JULY, 1998
3. LAMP INDICATIONS AND SWITCH SETTINGS OF APPLICATION CIRCUIT CARDS
Table 4-2 below shows the application circuit cards to be explained in this section.
* MB=Make Busy
Table 4-2  Table of Application Circuit Cards
NAME
(FUNCTIONAL 
NAME)EXISTENCE OF 
LAMPS
X: PROVIDED
—: NOT PROVIDEDEXISTENCE OF 
SWITCHES
X: PROVIDED
—: NOT PROVIDEDEXTRACTION/INSER-
TION WITH POWER ON
X: ALLOWED
D: ALLOWED AFTER MB*
—: NOT ALLOWED
REFERENCE 
PAG E...