Page 81
ND-45504 (E) CHAPTER 4 Addendum-001 Page 68-1 JULY, 1998 Revision 2.1 PN-CC01 (ETHER) PN-CC01 (ETHER) 1. Location of Lamps, Switches, and Connectors PN-CC01 (ETHER) Card RUN MB LINK XMT RCV RVP SW2 SW1 ERR 10 BASE-T IP
Page 82
CHAPTER 4 ND-45504 (E) Page 68-2 Addendum-001 Revision 2.1 JULY, 1998 PN-CC01 (ETHER) 2. Lamp Indications Lamp Indications LAMP NAME COLOR FUNCTION RUN Green Flashes at 60 IPM while this card is operating normally. LINK Green Lights when link is established. XMT Green Lights when it is transmitting the data. RCV Green Lights when it is receiving the data. RVP Green Lights only when it is receiving the data with its own IP address. ERR Not used
Page 83
ND-45504 (E) CHAPTER 4 Addendum-001 Page 68-3 JULY, 1998 Revision 2.1 PN-CC01 (ETHER) 3. Switch Settings Note 1:When the power is on, set the MB switch to ON (UP position) before plugging/unplugging the Circuit card. Note 2:Each equipment must have a unique MAC address to distinguish between systems. Therefore, when more than one PBX is installed in the same network, assign the lower 4 digits of the following MAC address by SW1 and SW2 to prevent duplicate addresses. Switch Settings SWITCH NAMESWITCH...
Page 84
CHAPTER 4 ND-45504 (E) Page 68-4 Addendum-001 Revision 2.1 JULY, 1998 This page is for your notes.
Page 85
ND-45504 (E) CHAPTER 4 Page 69 Revision 2.0 PN-CK00 (PLO) PN-CK00 (PLO) 1. Locations of Lamps, Switches, and Connectors PN-CK00 (PLO) Card 2. Lamp Indications DRIFT: Means the status which the oscillation of clock signal from the PN-CK00 is not synchronized with the network. Lamp Indications LAMP NAME COLOR FUNCTION SYNC Green Lights while clock signals from this card are sent out and are not DRIFT status. PLO0 GreenLights while receiving clock signals from the network to the PLO0 input on this card....
Page 86
CHAPTER 4 ND-45504 (E) Page 70 Addendum-001 Revision 2.1 JULY, 1998 PN-CK00 (PLO) (3) Switch Settings The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. Switch Settings SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK MB (Toggle SW) NoteUP For make-busy For normal operation SW0 (Piano Key SW) 1,...
Page 87
ND-45504 (E) CHAPTER 4 Addendum-001 Page 71 JULY, 1998 Revision 2.1 PN-CK00 (PLO) Note 1: When the power is on, flip the MB switch ON (UP position) before plugging/unplugging the circuit card. Note 2:When using this card, set the SW2 switch on the PN-CP00/PN-CP00-B/PN-CP03 (MP) as follows. SW2-2: OFF SW2-3: ON Note 3:When using this card for providing a master office clock signal, set the SW0 switch on the PN-CK00 and the SW switch on the PN-24DTA/PN-24DTA-A or the PN-30DTC/PN-30DTC-A mounted in PIM0 as...
Page 88
CHAPTER 4 ND-45504 (E) Pag e 72 Revision 2.0 PN-24DTA (DTI) PN-24DTA (DTI) 1. Locations of Lamps, Switches, and Connectors PN-24DTA (DTI) Card 2. Lamp Indications Lamp Indications LAMP NAME COLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally. CRC Red Lights when detecting Cyclic Redundancy Checking (CRC) errors. PCM Red Lights when detecting PCM signal loss. FRM Red Lights when detecting a Frame Alignment signal loss. RMT Red Lights when receiving a Frame Alignment signal...
Page 89
ND-45504 (E) CHAPTER 4 Page 73 Revision 2.0 PN-24DTA (DTI) (3) Switch Settings Switch Settings SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SENS (Rotary SW) Note 14 - F Set the switch to match the AP Number (04 - 15) to be set by CM05. 0 - 3 Not used MB (Toggle SW) Note 2UPFor make-busy For normal operation SW (Piano Key SW) 1ONClock signal from a master office is sent to the PLO 0 in- put on the MP card. OFFClock signal from a master office is not sent to the PLO 0 input on the MP card....
Page 90
CHAPTER 4 ND-45504 (E) Pag e 74 Revision 2.0 PN-24DTA (DTI) The figure in the SWITCH NAME column and the position in in the SETTING POSITION col- umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. Note 1:Set the groove on the switch knob to the intended switch position. Note 2:When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit card. Note...