ND-45504 (E) CHAPTER 4
Addendum-001 Page 68-1
JULY, 1998 Revision 2.1
PN-CC01 (ETHER)
PN-CC01 (ETHER)
1. Location of Lamps, Switches, and Connectors
PN-CC01 (ETHER) Card
RUN
MB
LINK
XMT
RCV
RVP SW2
SW1
ERR
10 BASE-T
IP 

Page 82

CHAPTER 4 ND-45504 (E)
Page 68-2 Addendum-001
Revision 2.1 JULY, 1998
PN-CC01 (ETHER)
2. Lamp Indications
Lamp Indications
LAMP NAME COLOR FUNCTION
RUN Green Flashes at 60 IPM while this card is operating normally.
LINK Green Lights when link is established.
XMT Green Lights when it is transmitting the data.
RCV Green Lights when it is receiving the data.
RVP Green Lights only when it is receiving the data with its own IP address.
ERR Not used 

Page 83

ND-45504 (E) CHAPTER 4
Addendum-001 Page 68-3
JULY, 1998 Revision 2.1
PN-CC01 (ETHER)
3. Switch Settings
Note 1:When the power is on, set the MB switch to ON (UP position) before plugging/unplugging the Circuit card.
Note 2:Each equipment must have a unique MAC address to distinguish between systems. Therefore, when more
than one PBX is installed in the same network, assign the lower 4 digits of the following MAC address by
SW1 and SW2 to prevent duplicate addresses. 
Switch Settings 
SWITCH
NAMESWITCH...

Page 84

CHAPTER 4 ND-45504 (E)
Page 68-4 Addendum-001
Revision 2.1 JULY, 1998
This page is for your notes. 

Page 85

ND-45504 (E) CHAPTER 4
Page 69
Revision 2.0
PN-CK00 (PLO)
PN-CK00 (PLO)
1. Locations of Lamps, Switches, and Connectors
PN-CK00 (PLO) Card
2. Lamp Indications
DRIFT: Means the status which the oscillation of clock signal from the PN-CK00 is not synchronized with
the network.
Lamp Indications
LAMP NAME COLOR FUNCTION
SYNC Green Lights while clock signals from this card are sent out and are not DRIFT status.
PLO0 GreenLights while receiving clock signals from the network to the PLO0 input on this 
card....

Page 86

CHAPTER 4 ND-45504 (E)
Page 70 Addendum-001
Revision 2.1 JULY, 1998
PN-CK00 (PLO)
(3) Switch Settings
The figure in the SWITCH NAME column and the position in   in the SETTING POSITION
column indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
Switch Settings
SWITCH NAMESWITCH
NUMBERSETTING
POSITIONFUNCTION CHECK
MB (Toggle SW)
NoteUP For make-busy
For normal operation
SW0 (Piano Key SW)
1,...

Page 87

ND-45504 (E) CHAPTER 4
Addendum-001 Page 71
JULY, 1998 Revision 2.1
PN-CK00 (PLO)
Note 1:
When the power is on, flip the MB switch ON (UP position) before plugging/unplugging the circuit card.
Note 2:When using this card, set the SW2 switch on the PN-CP00/PN-CP00-B/PN-CP03 (MP) as follows.
SW2-2: OFF
SW2-3: ON
Note 3:When using this card for providing a master office clock signal, set the SW0 switch on the PN-CK00 and
the SW switch on the PN-24DTA/PN-24DTA-A or the PN-30DTC/PN-30DTC-A mounted in PIM0 as...

Page 88

CHAPTER 4 ND-45504 (E)
Pag e 72
Revision 2.0
PN-24DTA (DTI)
PN-24DTA (DTI)
1. Locations of Lamps, Switches, and Connectors
PN-24DTA (DTI) Card
2. Lamp Indications
Lamp Indications
LAMP NAME COLOR FUNCTION
RUN Green Flashes at 120 IPM while this card is operating normally.
CRC Red Lights when detecting Cyclic Redundancy Checking (CRC) errors.
PCM Red Lights when detecting PCM signal loss.
FRM Red Lights when detecting a Frame Alignment signal loss.
RMT Red Lights when receiving a Frame Alignment signal...

Page 89

ND-45504 (E) CHAPTER 4
Page 73
Revision 2.0
PN-24DTA (DTI)
(3) Switch Settings
Switch Settings 
SWITCH
NAMESWITCH
NUMBERSETTING
POSITIONFUNCTION CHECK
SENS
(Rotary SW)
Note 14 - F Set the switch to match the AP Number (04 - 15) to be set by CM05.
0 - 3 Not used
MB (Toggle SW)
Note 2UPFor make-busy
For normal operation
SW
(Piano Key SW)
1ONClock signal from a master office is sent to the PLO 0 in-
put on the MP card.
OFFClock signal from a master office is not sent to the PLO 
0 input on the MP card....

Page 90

CHAPTER 4 ND-45504 (E)
Pag e 74
Revision 2.0
PN-24DTA (DTI)
The figure in the SWITCH NAME column and the position in   in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
 , the setting of the switch varies with the system concerned.
Note 1:Set the groove on the switch knob to the intended switch position.
Note 2:When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit
card.
Note...