Page 61

ND-45504 (E) CHAPTER 4
Page 53
Revision 2.0
PN-AP00-A (AP00)
PN-AP00-A (AP00)
1. Locations of Lamp, Switches, and Connectors
PN-AP00-A (AP00) Card
MB
SW0
SENSE
RUN
MB
SW1
WE
RS3 L3
L2
L1
L0
RS2
RS1
RS0 J16 

Page 62

CHAPTER 4 ND-45504 (E)
Pag e 54
Revision 2.0
PN-AP00-A (AP00)
(2) Lamp Indications
Lamp Indications
LAMP NAME COLOR FUNCTION
RUN Green Flashes at 120 IPM while this card is operating normally.
WE Red Not used.
L0 - L3
GreenSecond data setting value for the first data 250 of CM D001
0 1 (port 0) - 3 (port 2)
L3Indication of the transmitting status of 
port 0Indication of the status of CTS signal on 
port 0 - 2
L2Indication of the transmitting status of 
port 1Indication of the status of DCD signal 
on...

Page 63

ND-45504 (E) CHAPTER 4
Page 55
Revision 2.0
PN-AP00-A (AP00)
(3) Switch Settings
Switch Settings 
SWITCH NAMESWITCH
NUMBERSETTING
POSITIONFUNCTION CHECK
SENSE
(Rotary SW)
Note 14 - FSet the switch to match the AP Number (04 - 15) to be set by 
CM05.
0 - 3 Not used
MB (Toggle SW)
Note 2UP For make-busy
For normal operation
SW1 (Piano Key SW)
1For normal operation
OFF Not used
2For normal operation
OFF For AP data clearing by CMD100/CMD101
3For normal operation
OFF For AP data clearing by CMD100/CMD101
4...

Page 64

CHAPTER 4 ND-45504 (E)
Pag e 56
Revision 2.0
PN-AP00-A (AP00)
SW0 (Dip SW)
1
Note 3ONEnables the receive clock from the DCE (Mo-
dem) side when the No. 0 Port is synchronous. 
(Clock is received at the RXC terminal.)
OFF• Uses the internal clock as the receive clock
when the No. 0 Port is synchronous
• When the No. 0 Port  is asynchronous
2ONEnables transmit clock from the DCE (Mo-
dem) side when the No. 0 Port is synchronous. 
(Clock is received at the TXC (2) terminal.)
OFF• Uses the internal clock as...

Page 65

ND-45504 (E) CHAPTER 4
Page 57
Revision 2.0
PN-AP00-A (AP00)
The figure in the SWITCH NAME column and the position in    in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
Switch Settings (Continued)
SWITCH NAMESWITCH
NUMBERSETTING
POSITIONFUNCTION CHECK
SW0
5
Note 4ON• Uses the internal clock as the receive
clock when the No. 0 Port is synchro-
nous.
• When the...

Page 66

CHAPTER 4 ND-45504 (E)
Pag e 58
Revision 2.0
PN-AP00-A (AP00)
Note 1:
Set the groove on the switch knob to the desired switch position.
Note 2:When the power is on,  flip the MB switch to ON (UP position) before plugging/unplugging the circuit
card.
Note 3:The SW 1 is used to select the AP operating mode as shown below.
On line : Normal operating mode. The AP should be always in the “On line”, other than when you delete the AP
data.
Off line : The mode for AP data clearing by the command CMD100/CMD101....

Page 67

ND-45504 (E) CHAPTER 4
Page 59
Revision 2.0
PN-AP01 (AP01)
PN-AP01 (AP01)
1. Locations of Lamps, Switches, and Connectors
PN-AP01 (AP01) Card
2. Lamp Indications
Lamp Indications
LAMP NAME COLOR FUNCTION
RUN Green Flashes at 120 IPM while this card is operating normally.
L0-L3L3
GreenIndication of the status of CTS signal on the RS-232C port.
L2 Indication of the status of DCD signal on the RS-232C port.
L1 Indication of the status of TXD signal on the RS-232C port
L0 Indication of the status of RXD...

Page 68

CHAPTER 4 ND-45504 (E)
Pag e 60
Revision 2.0
PN-AP01 (AP01)
(3) Switch Settings
Switch Settings 
SWITCH NAMESWITCH
NUMBERSETTING
POSITIONFUNCTION CHECK
SENSE
(Rotary SW)
Note 14 - F Set the switch to match the AP Number (04 - 15) to be set by 
CM05.
0 - 3 Not used
MB(Toggle SW)
Note 2UP
For make-busy
For normal operation
SW1 (Piano Key
SW)1For normal operation
OFF Not used
2For normal operation
OFF Not used
3For normal operation
OFF Not used
4For normal operation
OFFNot used
AP NO.
SW NO.10 04 05 06 07...

Page 69

ND-45504 (E) CHAPTER 4
Page 61
Revision 2.0
PN-AP01 (AP01)
The figure in the SWITCH NAME column and the position in    in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
Note 1:Set the groove on the switch knob to the desired switch position.
Note 2:When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit
card.
SW0 (Dip...

Page 70

CHAPTER 4 ND-45504 (E)
Pag e 62
Revision 2.0
PN-BRTA (BRI)
PN-BRTA (BRI)
1. Locations of Lamps, Switches, and Connectors 
PN-BRTA (BRI) Card
SENS
RUN
MB
B1
B2
D
ALM
SW0
SW1 
Start reading NEC Neax2000 Ivs Circuit Card Manual

Related Manuals for NEC Neax2000 Ivs Circuit Card Manual

All NEC manuals