Home > NEC > Communications System > NEC Neax2000 Ivs Circuit Card Manual

NEC Neax2000 Ivs Circuit Card Manual

Here you can view all the pages of manual NEC Neax2000 Ivs Circuit Card Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 21

ND-45504 (E) CHAPTER 3
Page 13
Revision 2.0
2.4 PN-BS00-A/PN-BS00-B (BS00), PN-BS01-A/PN-BS01-B (BS01)
1. In a one-PIM system, neither the PN-BS00-A/PN-BS00-B nor the PN-BS01-A/PN-BS01-B is needed.
2. When the system is equipped with more than one PIM, mount a PN-BS00-A/PN-BS00-B in the BUS slot
of PIM0 or PIM(H)0.
3. When the system is equipped with more than one PIM, mount one PN-BS01-A/PN-BS01-B in the BUS
slot of PIM1 through PIM7, as required.
Figure 3-4   BS00/BS01 Card Mounting Slots
2.5 PN-PW00...

Page 22

CHAPTER 3 ND-45504 (E)
Page 14 Addendum-001
Revision 2.1 JULY, 1998
3. INSTALLATION CONDITIONS FOR APPLICATION CIRCUIT CARDS
1. When the system is equipped with only one PIM:
• An application circuit card can be mounted in the AP0 through AP6, and AP8 slots.
• An application circuit card can not be mounted in the AP6 slot if any of the following is true.
– A PN-2DLCC is used.
– A PN-AP01 is used.
– OAI, ACD, No. 7 CCIS or ISDN is used.
– The PN-CP02s are used.
2. When the system is equipped with more...

Page 23

ND-45504 (E) CHAPTER 3
Page 15
Revision 2.0
Figure 3-5   Application Circuit Card Mounting Slots
•Line/trunk circuit cards can also be mounted in AP0 - AP5 slots.
BUS/AP8FP/AP6 MP/FP/AP7
BUILT-IN BATTERY PIM0-7
AP5
AP4
AP3
AP2
AP1
AP0
PWR*
LT SLOTS (00-09)
•Line/trunk circuit cards can also be mounted in AP0 - AP5 slots.
BUS/AP8MP1 MP0
BUILT-IN BATTERY PIMH (0)
AP5
AP4
AP3
AP2
AP1
AP0
PWR*
LT SLOTS (00-09) 

Page 24

CHAPTER 3 ND-45504 (E)
Pag e 16
Revision 2.0
4. INSTALLATION CONDITIONS FOR LINE/TRUNK CIRCUIT CARDS
Mount the line/trunk circuit cards in the LT00 through LT15 slots of PIM0/PIM(H)0 through PIM7.
Figure 3-6   Line/Trunk Circuit Card Mounting Slots
•Application circuit cards can also be mounted in the LT10 through LT15 slots.
BUS/AP8AP6 MP/FP/AP7
BUILT-IN BATTERY PIM0-7
LT15
LT14
LT13
LT12
LT11
LT10
LT09
LT08
LT07
LT00 LT01
LT02 LT03 LT04 LT05 LT06
PWR*
•Application circuit cards can also be mounted in...

Page 25

ND-45504 (E) CHAPTER 4
Page 17
Revision 2.0
CHAPTER 4 LAMP INDICATIONS AND SWITCH SETTINGS
This chapter explains various circuit cards used in the PBX with respect to the following items. Explanations
are given in the alphabetical order of the circuit card names within each circuit card category (Control, Appli-
cation, and Line/Trunk).
1. Locations of Lamps, Switches, and Connectors
The locations of lamps, switches, and connectors of each circuit card are shown by a face layout.
2. Lamp Indications
The...

Page 26

CHAPTER 4 ND-45504 (E)
Pag e 18
Revision 2.0
1. PRECAUTION IN HANDLING
When handling a circuit card, the installer must wear a grounded wrist strap to protect the circuit card from static
electricity.
Figure 4-1   Static Electricity Precautions (1 of 2)
CARD FRONT
PBX
WRIST STRAP •  WHEN PLUGGING/UNPLUGGING A CIRCUIT CARD
•  WHEN HOLDING A CIRCUIT CARD
FRAME GROUND SCREW
CONNECT THE GROUND WIRE TO THE 
FRAME EARTH OF THE EQUIPMENT.
NEVER TOUCH THE COMPONENTS OR 
SOLDERED SURFACE WITH BARE HANDS. 

Page 27

ND-45504 (E) CHAPTER 4
Page 19
Revision 2.0
Figure 4-1  Static Electricity Precautions (2 of 2)
WEAR A WRIST STRAP AND PERFORM
THE WORK STANDING ON A GROUNDED
CONDUCTIVE WORK SURFACE.
WHEN CARRYING A CIRCUIT
CARD AROUND, KEEP THE
CARD IN THE CONDUCTIVE
POLYETHYLENE BAG. CONDUCTIVE
POLYETHYLENE
BAG CIRCUIT
    CARDCIRCUIT
    CARD •  WHEN SETTING SWITCHES ON A CIRCUIT CARD
•  WHEN CARRYING A CIRCUIT CARD 

Page 28

CHAPTER 4 ND-45504 (E)
Pag e 20
Revision 2.0
Figure 4-2   Circuit Card Handling Precautions
CARD FRONT
NEVER TOUCH THE COMPONENTS 
OR SOLDERED SURFACE WITH 
BASE HANDS.
PBX
The installer must hold the edge of circuit card, when plugging or unplugging the circuit card.  If you touch
another area, you may be exposed to hazardous voltages.
CAUTION 

Page 29

ND-45504 (E) CHAPTER 4
Addendum-002 Page 21
OCTOBER, 1998 Revision 2.2
2. LAMP INDICATIONS AND SWITCH SETTINGS OF CONTROL CIRCUIT CARDS
Table 4-1 below shows the control circuit cards to be explained in this section.
* MB = Make Busy
Table 4-1  Table of Control Circuit Cards
NAME
(FUNCTIONAL 
NAME)EXISTENCE OF 
LAMPS
X: PROVIDED
—: NOT PROVIDEDEXISTENCE OF 
SWITCHES
X: PROVIDED
—: NOT PROVIDEDEXTRACTION/INSERTION 
WITH POWER ON
X: ALLOWED
D: ALLOWED AFTER MB*
—: NOT ALLOWEDREFERENCE 
PA G E
PN-BS00-A/...

Page 30

CHAPTER 4 ND-45504 (E)
Pag e 22
Revision 2.0
PN-BS00-A/PN-BS00-B (BS00)
PN-BS00-A/PN-BS00-B (BS00)
1. Locations of Lamps, Switches, and Connectors
PN-BS00-A/PN-BS00-B (BS00) Card
2. Lamp Indications
This card has no indicator lamps.
MB
CN2
CN1 
Start reading NEC Neax2000 Ivs Circuit Card Manual