ND-45504 (E) CHAPTER 3 Page 13 Revision 2.0 2.4 PN-BS00-A/PN-BS00-B (BS00), PN-BS01-A/PN-BS01-B (BS01) 1. In a one-PIM system, neither the PN-BS00-A/PN-BS00-B nor the PN-BS01-A/PN-BS01-B is needed. 2. When the system is equipped with more than one PIM, mount a PN-BS00-A/PN-BS00-B in the BUS slot of PIM0 or PIM(H)0. 3. When the system is equipped with more than one PIM, mount one PN-BS01-A/PN-BS01-B in the BUS slot of PIM1 through PIM7, as required. Figure 3-4 BS00/BS01 Card Mounting Slots 2.5 PN-PW00...
Page 22
CHAPTER 3 ND-45504 (E) Page 14 Addendum-001 Revision 2.1 JULY, 1998 3. INSTALLATION CONDITIONS FOR APPLICATION CIRCUIT CARDS 1. When the system is equipped with only one PIM: • An application circuit card can be mounted in the AP0 through AP6, and AP8 slots. • An application circuit card can not be mounted in the AP6 slot if any of the following is true. – A PN-2DLCC is used. – A PN-AP01 is used. – OAI, ACD, No. 7 CCIS or ISDN is used. – The PN-CP02s are used. 2. When the system is equipped with more...
Page 23
ND-45504 (E) CHAPTER 3 Page 15 Revision 2.0 Figure 3-5 Application Circuit Card Mounting Slots •Line/trunk circuit cards can also be mounted in AP0 - AP5 slots. BUS/AP8FP/AP6 MP/FP/AP7 BUILT-IN BATTERY PIM0-7 AP5 AP4 AP3 AP2 AP1 AP0 PWR* LT SLOTS (00-09) •Line/trunk circuit cards can also be mounted in AP0 - AP5 slots. BUS/AP8MP1 MP0 BUILT-IN BATTERY PIMH (0) AP5 AP4 AP3 AP2 AP1 AP0 PWR* LT SLOTS (00-09)
Page 24
CHAPTER 3 ND-45504 (E) Pag e 16 Revision 2.0 4. INSTALLATION CONDITIONS FOR LINE/TRUNK CIRCUIT CARDS Mount the line/trunk circuit cards in the LT00 through LT15 slots of PIM0/PIM(H)0 through PIM7. Figure 3-6 Line/Trunk Circuit Card Mounting Slots •Application circuit cards can also be mounted in the LT10 through LT15 slots. BUS/AP8AP6 MP/FP/AP7 BUILT-IN BATTERY PIM0-7 LT15 LT14 LT13 LT12 LT11 LT10 LT09 LT08 LT07 LT00 LT01 LT02 LT03 LT04 LT05 LT06 PWR* •Application circuit cards can also be mounted in...
Page 25
ND-45504 (E) CHAPTER 4 Page 17 Revision 2.0 CHAPTER 4 LAMP INDICATIONS AND SWITCH SETTINGS This chapter explains various circuit cards used in the PBX with respect to the following items. Explanations are given in the alphabetical order of the circuit card names within each circuit card category (Control, Appli- cation, and Line/Trunk). 1. Locations of Lamps, Switches, and Connectors The locations of lamps, switches, and connectors of each circuit card are shown by a face layout. 2. Lamp Indications The...
Page 26
CHAPTER 4 ND-45504 (E) Pag e 18 Revision 2.0 1. PRECAUTION IN HANDLING When handling a circuit card, the installer must wear a grounded wrist strap to protect the circuit card from static electricity. Figure 4-1 Static Electricity Precautions (1 of 2) CARD FRONT PBX WRIST STRAP • WHEN PLUGGING/UNPLUGGING A CIRCUIT CARD • WHEN HOLDING A CIRCUIT CARD FRAME GROUND SCREW CONNECT THE GROUND WIRE TO THE FRAME EARTH OF THE EQUIPMENT. NEVER TOUCH THE COMPONENTS OR SOLDERED SURFACE WITH BARE HANDS.
Page 27
ND-45504 (E) CHAPTER 4 Page 19 Revision 2.0 Figure 4-1 Static Electricity Precautions (2 of 2) WEAR A WRIST STRAP AND PERFORM THE WORK STANDING ON A GROUNDED CONDUCTIVE WORK SURFACE. WHEN CARRYING A CIRCUIT CARD AROUND, KEEP THE CARD IN THE CONDUCTIVE POLYETHYLENE BAG. CONDUCTIVE POLYETHYLENE BAG CIRCUIT CARDCIRCUIT CARD • WHEN SETTING SWITCHES ON A CIRCUIT CARD • WHEN CARRYING A CIRCUIT CARD
Page 28
CHAPTER 4 ND-45504 (E) Pag e 20 Revision 2.0 Figure 4-2 Circuit Card Handling Precautions CARD FRONT NEVER TOUCH THE COMPONENTS OR SOLDERED SURFACE WITH BASE HANDS. PBX The installer must hold the edge of circuit card, when plugging or unplugging the circuit card. If you touch another area, you may be exposed to hazardous voltages. CAUTION
Page 29
ND-45504 (E) CHAPTER 4 Addendum-002 Page 21 OCTOBER, 1998 Revision 2.2 2. LAMP INDICATIONS AND SWITCH SETTINGS OF CONTROL CIRCUIT CARDS Table 4-1 below shows the control circuit cards to be explained in this section. * MB = Make Busy Table 4-1 Table of Control Circuit Cards NAME (FUNCTIONAL NAME)EXISTENCE OF LAMPS X: PROVIDED —: NOT PROVIDEDEXISTENCE OF SWITCHES X: PROVIDED —: NOT PROVIDEDEXTRACTION/INSERTION WITH POWER ON X: ALLOWED D: ALLOWED AFTER MB* —: NOT ALLOWEDREFERENCE PA G E PN-BS00-A/...
Page 30
CHAPTER 4 ND-45504 (E) Pag e 22 Revision 2.0 PN-BS00-A/PN-BS00-B (BS00) PN-BS00-A/PN-BS00-B (BS00) 1. Locations of Lamps, Switches, and Connectors PN-BS00-A/PN-BS00-B (BS00) Card 2. Lamp Indications This card has no indicator lamps. MB CN2 CN1