ND-45504 (E) CHAPTER 4 Addendum-002 Page 33 OCTOBER, 1998 Revision 2.2 PN-CP00-B/PN-CP00-C (MP) The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. Note:Set the groove on the switch to the desired switch position. Switch Settings (Continued) SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SW2...
Page 42
CHAPTER 4 ND-45504 (E) Page 34 Addendum-002 Revision 2.2 OCTOBER, 1998 PN-CP03/PN-CP03-C (MP) PN-CP03/PN-CP03-C (MP) 1. Locations of Lamps, Switches, and Connectors PN-CP03/PN-CP03-C (MP) Card 2. Lamp Indications Lamp Indications LAMP NAME COLOR FUNCTION RUN Green Flashes at 120 IPM while the circuit card is operating normally. CLKIN Green Lights while receiving clock signals to the PLO oscillator. SW3 RUN SW1 SW2 CLK JAC K RS1 RS0 VR JP0 JP1
Page 43
ND-45504 (E) CHAPTER 4 Addendum-002 Page 35 OCTOBER, 1998 Revision 2.2 PN-CP03/PN-CP03-C (MP) (3) Switch Settings Switch Settings SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SW3 (Rotary SW) Note0 ~ FOn Line (Call processing is in progress) 2Off Line (Call processing is stopped) • I/O port: Depending on CM40 YY=08 3Off Line (Call processing is stopped) • I/O port: 1200 bps (Fixed) B For clearing the office data C For setting the resident system program 1, 4 ~ 9 A, D ~ FNot used SW1 (Push SW)...
Page 44
CHAPTER 4 ND-45504 (E) Page 36 Addendum-002 Revision 2.2 OCTOBER, 1998 PN-CP03/PN-CP03-C (MP) The figure in the SWITCH NAME column and the position in in the SETTING POSITION col- umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. Note:Set the groove on the switch knob to the desired switch position. Switch Settings (Continued) SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SW2...
Page 45
ND-45504 (E) CHAPTER 4 Page 37 Revision 2.0 PN-CP01 (FP) PN-CP01 (FP) 1. Locations of Lamps, Switches, and Connectors PN-CP01 (FP) Card 2. Lamp Indications Lamp Indications LAMP NAME COLOR FUNCTION RUN Green Flashes at 120 IPM while the circuit card is operating normally. MB RUN SW1
Page 46
CHAPTER 4 ND-45504 (E) Pag e 38 Revision 2.0 PN-CP01 (FP) (3) Switch Settings The figure in the SWITCH NAME column and the position in in the SETTING POSITION col- umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. Note 1:Set the groove on the switch knob to the desired switch position. Note 2:When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the...
Page 47
ND-45504 (E) CHAPTER 4 Addendum-002 Page 39 OCTOBER, 1998 Revision 2.2 PN-CP02/PN-CP02-C (MP) PN-CP02/PN-CP02-C (MP) 1. Locations of Lamps, Switches, and Connectors PN-CP02/PN-CP02-C (MP) Card 2. Lamp Indications Lamp Indications LAMP NAME COLOR FUNCTION RUN Gree n• Flashes at 120 IPM while the circuit card is active status and operating normally. • Flashes at 30 IPM or 15 IPM while the circuit card is stand by status. Normally operating: 30 IPM (1 sec - ON, 1 sec - OFF) Copying office data: 15 IPM (3...
Page 48
CHAPTER 4 ND-45504 (E) Page 40 Addendum-002 Revision 2.2 OCTOBER, 1998 PN-CP02/PN-CP02-C (MP) (3) Switch Settings Switch Settings SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SW3 (Rotary SW) Note 10 ~ F Note 2On Line (Call processing is in progress) 2Off Line (Call processing is stopped) • I/O port: Depending on CM40 YY=08 3Off Line (Call processing is stopped) • I/O port: 1200 bps (Fixed) B For clearing the office data C For setting the resident system program 1, 4 ~ 9 A, D ~ FNot used SW1...
Page 49
ND-45504 (E) CHAPTER 4 Addendum-002 Page 41 OCTOBER, 1998 Revision 2.2 PN-CP02/PN-CP02-C (MP) The figure in the SWITCH NAME column and the position in in the SETTING POSITION col- umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. Note 1:Set the groove on the switch to the desired switch position. Note 2:On the stand by status circuit card, the SW3 can be set to only “0” or “B”. Do not set...
Page 50
CHAPTER 4 ND-45504 (E) Pag e 42 Revision 2.0 PN-PW00 (EXTPWR) PN-PW00 (EXTPWR) 1. Locations of Lamps, Switches and Connectors PN-PW00 (EXTPWR) Card 2. Lamp Indications Lamp Indications LAMP NAME COLOR FUNCTION RUN Green Remains lit while –48 V power is being supplied RUN MB CONN