Home > NEC > Communications System > NEC Neax 2400 Ipx System Operations And Maintenance Manual

NEC Neax 2400 Ipx System Operations And Maintenance Manual

Here you can view all the pages of manual NEC Neax 2400 Ipx System Operations And Maintenance Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 181

NDA-24307 CHAPTER 3
Page 153
Issue 1
SYSTEM MESSAGES
[20H] Data Memory Verification Normal End
➀ Performed Diagnosis Item
➁ Verification of HD
➂ Verification of Data Memory
1: 20XX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁ ➂
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b1 b0
b2 b1 b0
[20H] Data Memory Verification Normal End
b0: 0/1 = -/HFD 0 is normal
b1: 0/1 = -/HFD 1 is normal
b0: 0/1 =...

Page 182

CHAPTER 3 NDA-24307
Page 154
Issue 1
SYSTEM MESSAGES
[30H] TSW ACT/STBY Changeover Normal End
➀ Performed Diagnosis Item
➁ Active TSW system after the 
changeover
1: 30XX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b0
[30H] TSW ACT/STBY Changeover Normal End
b0: 0/1 = TSW No. 0 is ACT/TSW No. 1 is ACT 

Page 183

NDA-24307 CHAPTER 3
Page 155
Issue 1
SYSTEM MESSAGES
[40H] CPU ACT/STBY Changeover Normal End
➀ Performed Diagnosis Item
➁ Active status information after 
changeover
1: 40XX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b1 b0
[40H] CPU ACT/STBY Changeover Normal End
b0: CPU
0/1 = No. 0 is ACT/No. 1 is ACT
b1: TSW
0/1 = No. 0 is ACT/No. 1 is ACT 

Page 184

CHAPTER 3 NDA-24307
Page 156
Issue 1
SYSTEM MESSAGES
[50H] No Trunk Ineffective Hold
➀ Performed Diagnosis Item
➁ MG and Unit of No. 
1: 50XX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b6 b5 b4 b3 b2 b1 b0
[50H] No Trunk Ineffective Hold
b0: Unit 0, Even-numbered MG 
1 = No Trunk Ineffective Hold
b1: Unit 1, Even-numbered MG 
1 = No Trunk...

Page 185

NDA-24307 CHAPTER 3
Page 157
Issue 1
SYSTEM MESSAGES
[70H] Call Forwarding Memory Clear Normal End
➀ Performed Diagnosis Item
1: 7000 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ 
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
[70H] Call Forwarding Memory Clear Normal End 

Page 186

CHAPTER 3 NDA-24307
Page 158
Issue 1
SYSTEM MESSAGES
[A0H] Periodic Back-up Normal
➀ Performed Diagnosis Item
➁ Information on Periodic Backup 
Normal End
➂ Backup Data to No. 0 system
➃Backup Data to No. 1 system
Note:The Number Sharing data load also affects the data load of Dual Station Calling Over-FCCS.
1: A0XX XX00 0000 XX00 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁ ➂ ➃
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000...

Page 187

NDA-24307 CHAPTER 3
Page 159
Issue 1
SYSTEM MESSAGES
[C0H] Detection of Remaining Link Normal End 
➀ Performed Diagnosis Item
1: C000 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ 
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b6 b5 b4 b3 b2 b1 b0
[C0H] Detection of Remaining Link Normal End  

Page 188

CHAPTER 3 NDA-24307
Page 160
Issue 1
SYSTEM MESSAGES
In a specific time cycle, the system allows a routine diagnosis in its hardware and software to determine if they
are operating properly. This message indicates that the system has been checked by the routine diagnosis
program and the result of the diagnosis is not normal.
➀ Detected Error Item
Note 1:This data is output at the ISW.
Note 2:This data is collected and output at the ISW.
Note 3:The data in this area will be diverse, according to the...

Page 189

NDA-24307 CHAPTER 3
Page 161
Issue 1
SYSTEM MESSAGES
[10H] Program Memory Verification Discrepancy 
➀ Detected Error Item
➁ Faulty HFD number
➂ Verification of Drive Number
➃ Data analyzed by NEC Engineers
1: 1000 XXXX XXXX XXXX 2: XXXX 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁ ➂ ➃
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b1 b0
b3 b2 b1 b0
[10H] Program Memory Verification Discrepancy
b0: 0/1 = -/HFD 0
b1:...

Page 190

CHAPTER 3 NDA-24307
Page 162
Issue 1
SYSTEM MESSAGES
[11H] Program Memory Verification Impossible (HFD Fault)
➀ Detected Error Item
➁ HFD No. (verification suspended)
➂ Error Type
➃ Data analyzed by NEC Engineers
➄ Error Drive Note
Note:
This data is available when ➂ is 00 Hex.
1: 11XX XXXX XXXX 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁ ➂ 
➃➄
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b1 b0
b7 b6...
Start reading NEC Neax 2400 Ipx System Operations And Maintenance Manual