NDA-24307 CHAPTER 3 Page 193 Issue 1 SYSTEM MESSAGES ➂ Probable cause for the failure b3 b2 b1 b0b0-b3: See Table. FLT IDCCITT ERROR FAC TO R 00 A S (F = 1) frame is received. 01 B DM (F = 1) response is received. 02 C UA (F = 1) response is received. 03 D UA (F = 0) response is received. 04 E DM (F = 0) response is received. 05 F SABME command is received. 06 G N200 Timeout (Link is set) 07 H N200 Timeout (Link is disconnected) 08 I N200 Timeout (Link failure is restored to normal) 09 J N (R) frame...
Page 222
CHAPTER 3 NDA-24307 Page 194 Issue 1 SYSTEM MESSAGES This message displays when the faults pertaining to CCIS/ISDN Link are restored to normal. ➀ Location of faulty CCH/DCH card ➁ Data to be Analyzed by NEC Engineers 1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 Default Alarm: NON13-JRestoration...
Page 223
NDA-24307 CHAPTER 3 Page 195 Issue 1 SYSTEM MESSAGES This message displays when a fault occurred to the Port Microprocessor (PM) within the CCH/DCH circuit card and the restart processing is executed . ➀ Location of faulty CCH/DCH card 1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 Default Alarm: SUP13-KCCH Reset...
Page 224
CHAPTER 3 NDA-24307 Page 196 Issue 1 SYSTEM MESSAGES This message displays when a digital line failure occurs on the DAI circuit card. ➀ DAI Card Mounting Location ➁ Kind of Fault 1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 b4 b3 b2 b1 b0 Default Alarm: SUP13-NDigital Line WarningDefault Grade: 1Grade Modified: Lamp...
Page 225
NDA-24307 CHAPTER 3 Page 197 Issue 1 SYSTEM MESSAGES This message displays when a digital line failure occurs in succession on the DAI circuit card. ➀ DAI Card Mounting Location ➁ Kind of Fault 1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 b4 b3 b2 b1 b0 Default Alarm: SUP13-ODigital Line FailureDefault Grade: 2Grade...
Page 226
CHAPTER 3 NDA-24307 Page 198 Issue 1 SYSTEM MESSAGES This message displays when a digital line failure is restored to normal. ➀ DAI Card Mounting Location ➁ Kind of Fault 1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 b4 b3 b2 b1 b0 Default Alarm: NON13-PDigital Line RestoreDefault Grade: 0Grade Modified: Lamp...
Page 227
NDA-24307 CHAPTER 3 Page 199 Issue 1 SYSTEM MESSAGES This message displays when the battery is operated in the due to the Digital Access Unit (DAU) power down. ➀ DAI Card Mounting Location 1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 Default Alarm: SUP13-QDAU Battery OperationDefault Grade: 1Grade Modified: Lamp...
Page 228
CHAPTER 3 NDA-24307 Page 200 Issue 1 SYSTEM MESSAGES This message displays when the main power of the Digital Access Unit (DAU) system is restored to normal, ending the temporary power acceptance from the battery observed in the message [13-Q] DAU Battery Operation.” ➀ DAI Card Mounting Location 1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7...
Page 229
NDA-24307 CHAPTER 3 Page 201 Issue 1 SYSTEM MESSAGES This message displays when a PWR circuit card failure is detected. ➀ Power Circuit Card Location ➁ Fault Information ➂ Power Card Classification See Chapter 4 for the Circuit Card Replacement Procedure. 1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ ➂ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b2 b1 b0 b4 b3 b2 b1 b0 Default Alarm:...
Page 230
CHAPTER 3 NDA-24307 Page 202 Issue 1 SYSTEM MESSAGES This message displays when a VPS failure is detected. ➀ Probable cause for the failure ➁ LENS of VPS ➂ LENS of VPS See Chapter 4 for the Circuit Card Replacement Procedure. 1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ ➂ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1...