Page 191
NDA-24307 CHAPTER 3 Page 163 Issue 1 SYSTEM MESSAGES [12H] Program Memory Verification Impossible (Fault at CPU side) ➀ Detected Error Item ➁ Cause for suspended verification 1: 12XX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b1 b0 [12H] Program Memory Verification Impossible (Fault at CPU side) 01H: CPU-to-CPU communication failure 02H: Check sum...
Page 192
CHAPTER 3 NDA-24307 Page 164 Issue 1 SYSTEM MESSAGES [20H] Data Memory Verification Discrepancy ➀ Detected Error Item ➁ Faulty HFD ➂ Diagnosed Data Memory ➃ Data analyzed by NEC Engineers 1: 20XX XX00 XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX ➀ ➁ ➂ ➃ 4: XXXX XXXX 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b1 b0 b2 b1 b0 [20H] Data Memory Verification Discrepancy b0: 0/1 = -/HFD 0 b1: 0/1 = -/HFD 1 b0: 0/1 =...
Page 193
NDA-24307 CHAPTER 3 Page 165 Issue 1 SYSTEM MESSAGES [21H] Data Memory Verification Impossible (HFD Fault) ➀ Detected Error Item ➁ Faulty HFD ➂ Diagnosed Data Memory ➃ Error Type ➄ Signal Code ➅ Data analyzed by NEC Engineers ➆ Error Drive Note:When ➃ (Error Type) is 00H, ➄ Signal Code, ➅ and ➆ Error Drive are valid. DM LDM NDM 1: 21XX XX00 XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: 0000 0000 0000 0000 ➀ ➁ ➂ ➃ ➄ ➅ ➆ ➃ ➄ ➅ ➆ ➃ ➄ ➅ ➆ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000...
Page 194
CHAPTER 3 NDA-24307 Page 166 Issue 1 SYSTEM MESSAGES [31H] TSW ACT/STBY Changeover Failure (ISW) Note:This data is output at the ISW ➀ Detected Error Item ➁ Active TSW No. ➂ FPC No. of ISW ➃ Number of MUX cards (ACT side) Note ➄ Number of MUX cards (STBY side) Note Note:This data is displayed when MUX failure occurs in LN side. 1: 31XX XX00 XXXX 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ ➂ ➃ ➄ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8:...
Page 195
NDA-24307 CHAPTER 3 Page 167 Issue 1 SYSTEM MESSAGES [32H] TSW ACT/STBY Changeover Failure (LN) Note:This data is collected and output at the ISW. ➀ Detected Error Item ➁ Active TSW No. ➂ FPC No. of LN ➃,➄, ➅, ➆ MUX card (ACT side) linkage condition 1: 32XX XX00 XXXX XXXX 2: XXXX XXXX 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ ➂ ➃ ➄ ➅ ➆ ➇ ➈ ➉ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b0 b7 b6 b5 b4 b3 b2 b1 b0 b7...
Page 196
CHAPTER 3 NDA-24307 Page 168 Issue 1 SYSTEM MESSAGES ➇, ➈, ➉, MUX card (STBY side) linkage condition b7 b6 b5 b4 b3 b2 b1 b0As shown in the table below, each bit represents the Unit number allocated for each MUX card position. When “1” is set, the corresponding MUX card (status: ACT) has a functional failure.11 MG1 MG0 Unit 3 Unit 2 Unit 1 Unit 0 Unit 3 Unit 2 Unit 1 Unit 0 MG3 MG2 Unit 3 Unit 2 Unit 1 Unit 0 Unit 3 Unit 2 Unit 1 Unit 0 MG5 MG4 Unit 3 Unit 2 Unit 1 Unit 0 Unit 3 Unit 2 Unit 1 Unit 0...
Page 197
NDA-24307 CHAPTER 3 Page 169 Issue 1 SYSTEM MESSAGES [41H] CPU ACT/STBY Changeover Failure ➀ Detected Error Item ➁ ACT Status Information 1: 41XX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b1 b0 [41H] CPU ACT/STBY Changeover Failure b0: CPU 0/1 = No. 0 is ACT/ No. 1 is ACT b1: TSW 0/1 = No. 0 is ACT/ No. 1 is ACT
Page 198
CHAPTER 3 NDA-24307 Page 170 Issue 1 SYSTEM MESSAGES [42H] CPU ACT/STBY Changeover Failure (DM Verification NG or PM Verification NG) ➀ Detected Error Item ➁ ACT Status Information 1: 42XX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b1 b0 [42H] CPU ACT/STBY Changeover Failure (DM or PM Verification NG) b0: CPU 0/1 = No. 0 is ACT/No. 1 is ACT b1:...
Page 199
NDA-24307 CHAPTER 3 Page 171 Issue 1 SYSTEM MESSAGES [43H] CPU ACT/STBY Changeover Failure (PCI Fault) ➀ Detected Error Item ➁ ACT Status Information 1: 43XX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b1 b0 [43H] CPU ACT/STBY Changeover Failure (PCI Fault) b0: CPU 0/1 = No. 0 is ACT/No. 1 is ACT b1: TSW 0/1 = No. 0 is ACT/No. 1 is ACT
Page 200
CHAPTER 3 NDA-24307 Page 172 Issue 1 SYSTEM MESSAGES [44H] CPU ACT/STBY Changeover Failure (Changeover NG or CPU RAM Copy NG) ➀ Detected Error Item ➁ ACT Status Information 1: 44XX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b1 b0 [44H] CPU ACT/STBY Changeover Failure Changeover NG or CPU RAM Copy NG) b0: CPU 0/1 = No. 0 is ACT/No. 1 is ACT b1:...