Page 191

NDA-24307 CHAPTER 3
Page 163
Issue 1
SYSTEM MESSAGES
[12H] Program Memory Verification Impossible (Fault at CPU side)
➀ Detected Error Item
➁ Cause for suspended verification
1: 12XX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b1 b0
[12H] Program Memory Verification Impossible (Fault at CPU side)
01H: CPU-to-CPU communication failure
02H: Check sum...

Page 192

CHAPTER 3 NDA-24307
Page 164
Issue 1
SYSTEM MESSAGES
[20H] Data Memory Verification Discrepancy
➀ Detected Error Item
➁ Faulty HFD
➂ Diagnosed Data Memory
➃ Data analyzed by NEC Engineers
1: 20XX XX00 XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX
➀ ➁ ➂ 
➃
4: XXXX XXXX 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b1 b0
b2 b1 b0
[20H] Data Memory Verification Discrepancy
b0: 0/1 = -/HFD 0
b1: 0/1 = -/HFD 1
b0: 0/1 =...

Page 193

NDA-24307 CHAPTER 3
Page 165
Issue 1
SYSTEM MESSAGES
[21H] Data Memory Verification Impossible (HFD Fault)
➀ Detected Error Item
➁ Faulty HFD
➂ Diagnosed Data Memory
➃ Error Type
➄ Signal Code
➅ Data analyzed by NEC Engineers
➆ Error Drive
Note:When ➃ (Error Type) is 00H, ➄ Signal Code, ➅ and ➆ Error Drive are valid.
DM LDM NDM
1: 21XX XX00 XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: 0000 0000 0000 0000
➀ ➁ ➂ ➃ ➄ ➅ ➆ ➃ ➄ ➅ ➆ ➃ ➄ ➅ ➆
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000...

Page 194

CHAPTER 3 NDA-24307
Page 166
Issue 1
SYSTEM MESSAGES
[31H] TSW ACT/STBY Changeover Failure (ISW)
Note:This data is output at the ISW
➀ Detected Error Item
➁ Active TSW No.
➂ FPC No. of ISW
➃ Number of MUX cards (ACT side) 
Note
➄ Number of MUX cards (STBY 
side) 
Note
Note:This data is displayed when MUX failure occurs in LN side.
1: 31XX XX00 XXXX 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁ ➂  ➃ ➄
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8:...

Page 195

NDA-24307 CHAPTER 3
Page 167
Issue 1
SYSTEM MESSAGES
[32H] TSW ACT/STBY Changeover Failure (LN)
Note:This data is collected and output at the ISW.
➀ Detected Error Item
➁ Active TSW No.
➂ FPC No. of LN
➃,➄, ➅, ➆ MUX card (ACT side) 
linkage condition
1: 32XX XX00 XXXX XXXX 2: XXXX XXXX 0000 0000 3: 0000 0000 0000 0000
➀ ➁ ➂ ➃ ➄ ➅ ➆ ➇ ➈ ➉
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b0
b7 b6 b5 b4 b3 b2 b1 b0
b7...

Page 196

CHAPTER 3 NDA-24307
Page 168
Issue 1
SYSTEM MESSAGES
➇, ➈, ➉,  MUX card (STBY side) 
linkage condition
b7 b6 b5 b4 b3 b2 b1 b0As shown in the table below, each bit represents the Unit number allocated 
for each MUX card position. When “1” is set, the corresponding MUX card 
(status: ACT) has a functional failure.11
MG1 MG0
Unit 3 Unit 2 Unit 1 Unit 0 Unit 3 Unit 2 Unit 1 Unit 0
MG3 MG2
Unit 3 Unit 2 Unit 1 Unit 0 Unit 3 Unit 2 Unit 1 Unit 0
MG5 MG4
Unit 3 Unit 2 Unit 1 Unit 0 Unit 3 Unit 2 Unit 1 Unit 0...

Page 197

NDA-24307 CHAPTER 3
Page 169
Issue 1
SYSTEM MESSAGES
[41H] CPU ACT/STBY Changeover Failure
➀ Detected Error Item
➁ ACT Status Information
1: 41XX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b1 b0
[41H] CPU ACT/STBY Changeover Failure
b0: CPU
0/1 = No. 0 is ACT/ No. 1 is ACT
b1: TSW
0/1 = No. 0 is ACT/ No. 1 is ACT 

Page 198

CHAPTER 3 NDA-24307
Page 170
Issue 1
SYSTEM MESSAGES
[42H] CPU ACT/STBY Changeover Failure (DM Verification NG or PM Verification NG)
➀ Detected Error Item
➁ ACT Status Information
1: 42XX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b1 b0
[42H] CPU ACT/STBY Changeover Failure (DM or PM Verification NG)
b0: CPU
0/1 = No. 0 is ACT/No. 1 is ACT
b1:...

Page 199

NDA-24307 CHAPTER 3
Page 171
Issue 1
SYSTEM MESSAGES
[43H] CPU ACT/STBY Changeover Failure (PCI Fault)
➀ Detected Error Item
➁ ACT Status Information
1: 43XX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b1 b0
[43H] CPU ACT/STBY Changeover Failure (PCI Fault)
b0: CPU
0/1 = No. 0 is ACT/No. 1 is ACT
b1: TSW
0/1 = No. 0 is ACT/No. 1 is ACT 

Page 200

CHAPTER 3 NDA-24307
Page 172
Issue 1
SYSTEM MESSAGES
[44H] CPU ACT/STBY Changeover Failure (Changeover NG or CPU RAM Copy NG)
➀ Detected Error Item
➁ ACT Status Information
1: 44XX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b1 b0
[44H] CPU ACT/STBY Changeover Failure
Changeover NG or CPU RAM Copy NG)
b0: CPU
0/1 = No. 0 is ACT/No. 1 is ACT
b1:...