NEC Neax 2400 Ipx System Operations And Maintenance Manual
Here you can view all the pages of manual NEC Neax 2400 Ipx System Operations And Maintenance Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 141
NDA-24307 CHAPTER 3 Page 113 Issue 1 SYSTEM MESSAGES This message displays when a PCI card failure occurs. ➀ Fault detection on PCI card ➁ Error status on PCI slot 0 ➂ Error status on PCI slot 1 ➃ Not used ➄ Error status on PCI slot 3 Note 1:Physical Connection Error Ethernet cable is disconnected. Ethernet cable has short-circuited. Ethernet straight/cross cable selection error Note 2:Hardware Fault Transmitter failure Controller lock-up 1: 0X0X 0X0X 0X00 0000 2: 0000 0000 0000 0000 3: 0000 0000...
Page 142
CHAPTER 3 NDA-24307 Page 114 Issue 1 SYSTEM MESSAGES This message displays when the PCI card, which was detected as faulty, is recovered. ➀ Detection of PCI restoration ➁Details on error restoration (PCI slot 0) ➂Details on error restoration (PCI slot 1) ➃Not used ➄Details on error restoration (PCI slot 3) Note:Physical Connection Error Ethernet cable is disconnected. Ethernet cable has short-circuited. Ethernet straight/cross cable selection error 1: 0X0X 0X0X 0X00 0000 2: 0000 0000 0000 0000 3:...
Page 143
NDA-24307 CHAPTER 3 Page 115 Issue 1 SYSTEM MESSAGES This message displays when any of the following faults are detected: Power failure Fuse blowing In-Frame abnormal temperature ➀ Probable cause for the failure ➁The frame in which a fault is detected ➂ Factor of the failure See Chapter 5 for repair procedure. 1: XX00 XXXX 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ ➂ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9:...
Page 144
CHAPTER 3 NDA-24307 Page 116 Issue 1 SYSTEM MESSAGES This message displays when a fault in either the ringer or howler tone occurs in the PWR card. ➀Unit and MG number of fault detection ➁ Kind of the fault 1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b2 b1 b0 b1 b0 Default Alarm: MN6-BRGU and Howler FailureDefault Grade: 3Grade Modified:...
Page 145
NDA-24307 CHAPTER 3 Page 117 Issue 1 SYSTEM MESSAGES This message displays when the CPU usage (occupancy) rate exceeds the value assigned to ASYD, SYS1, INDEX56, and the call origination from the pre-selected group of stations is restricted (i.e. Line Load Control is set). This system message is always indicated as 0. 1: 0000 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9:...
Page 146
CHAPTER 3 NDA-24307 Page 118 Issue 1 SYSTEM MESSAGES This message displays when the CPU usage (occupancy) rate becomes lower than the value assigned to ASYD, SYS1, INDEX57, and Line Load Control is cancelled. This system message is always indicated as 0. 1: 0000 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 Default Alarm: NON6-DLine Load Control...
Page 147
NDA-24307 CHAPTER 3 Page 119 Issue 1 SYSTEM MESSAGES This message displays to indicate the result of Bad Call Notification. ➀ Bad Call Notification 1: XXXX XXXX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: 0000 0000 0000 0000 ➀ ➁ ➂ ➃ ➄ ➅ ➆ ➇ ➈ ➉11 12 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 Default Alarm: SUP6-HBad Call NotificationDefault Grade: 2Grade Modified: Lamp Modified: b0-b3: Station...
Page 148
CHAPTER 3 NDA-24307 Page 120 Issue 1 SYSTEM MESSAGES When type of connection is intra-Station connection ➁ ~ ➃ Station number (see table) ➄ Called station number ➅ ~ ➇ Called station number (See table) ➈ Time Slot Number of Link 1 Note 1 ➉ Not used Time Slot Number of Link 2 Note 1 Not used Note 1:Station at which the operation was performed as shown in the figure below. b7 b6 b5 b4 b3 b2 b1 b0 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b4-b7b0-b3 ➁DC0 DC1 ➂DC2 DC3 ➃DC4 DC5 b0-b3: Number of digits for the...
Page 149
NDA-24307 CHAPTER 3 Page 121 Issue 1 SYSTEM MESSAGES When type of connection is Trunk connection ➁ ~ ➃ Station number (See table) ➄ Remote Route No. ➅ Remote Route No. ➆ Called trunk No. ➇ Not used ➈ Time Slot Number of Link 1 Note 1 ➉ Not used Time Slot Number of Link 2 Note 1 Not used Note 1:Station at which the operation was performed as shown below. b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b4-b7 b0-b3 ➁DC0 DC1 ➂DC2 DC3 ➃DC4 DC5 b0-b5: Route No. (1-63) b6:...
Page 150
CHAPTER 3 NDA-24307 Page 122 Issue 1 SYSTEM MESSAGES When type of connection is ACD Trunk connection ➁ ACD Trouble Kind Note 1:When“➁ (ACD Trouble Kind)” is 01 Hex: ➂ ~ ➅ Information on Calling Party ➆ ➇ Not Used ➈ ➉ Information on Calling Party Refer to Information on Held Party or 3rd Station/Trunk in 3-Party Connection Refer to Note 2:When“➁ (ACD Trouble Kind)” is 14 Hex: ➂ Issue of ACDP (First digit of decimal place) ➃ Issue of ACDP (Second digit of decimal place) Note 3:When“➁ (ACD Trouble Kind)”...