NDA-24307 CHAPTER 3
Page 113
Issue 1
SYSTEM MESSAGES
This message displays when a PCI card failure occurs.
➀ Fault detection on PCI card
➁ Error status on PCI slot 0
➂ Error status on PCI slot 1
➃ Not used
➄ Error status on PCI slot 3
Note 1:Physical Connection Error
Ethernet cable is disconnected.
Ethernet cable has short-circuited.
Ethernet straight/cross cable selection error
Note 2:Hardware Fault
Transmitter failure
Controller lock-up
1: 0X0X 0X0X 0X00 0000 2: 0000 0000 0000 0000 3: 0000 0000...

Page 142

CHAPTER 3 NDA-24307
Page 114
Issue 1
SYSTEM MESSAGES
This message displays when the PCI card, which was detected as faulty, is recovered.
➀ Detection of PCI restoration
➁Details on error restoration 
(PCI slot 0)
➂Details on error restoration 
(PCI slot 1)
➃Not used
➄Details on error restoration (PCI 
slot 3)
Note:Physical Connection Error
Ethernet cable is disconnected.
Ethernet cable has short-circuited.
Ethernet straight/cross cable selection error
1: 0X0X 0X0X 0X00 0000 2: 0000 0000 0000 0000 3:...

Page 143

NDA-24307 CHAPTER 3
Page 115
Issue 1
SYSTEM MESSAGES
This message displays when any of the following faults are detected:
Power failure
Fuse blowing
In-Frame abnormal temperature
➀ Probable cause for the failure
➁The frame in which a fault is 
detected
➂ Factor of the failure
See Chapter 5 for repair procedure.
1: XX00 XXXX 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀  ➁ ➂
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9:...

Page 144

CHAPTER 3 NDA-24307
Page 116
Issue 1
SYSTEM MESSAGES
This message displays when a fault in either the ringer or howler tone occurs in the PWR card.
➀Unit and MG number of fault 
detection
➁ Kind of the fault
1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b2 b1 b0
b1 b0
Default Alarm:
MN6-BRGU and Howler FailureDefault Grade:
3Grade Modified:...

Page 145

NDA-24307 CHAPTER 3
Page 117
Issue 1
SYSTEM MESSAGES
This message displays when the CPU usage (occupancy) rate exceeds the value assigned to ASYD, SYS1,
INDEX56, and the call origination from the pre-selected group of stations is restricted (i.e. Line Load Control
is set). This system message is always indicated as 0.
1: 0000 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9:...

Page 146

CHAPTER 3 NDA-24307
Page 118
Issue 1
SYSTEM MESSAGES
This message displays when the CPU usage (occupancy) rate becomes lower than the value assigned to ASYD,
SYS1, INDEX57, and Line Load Control is cancelled. This system message is always indicated as 0.
1: 0000 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
Default Alarm:
NON6-DLine Load Control...

Page 147

NDA-24307 CHAPTER 3
Page 119
Issue 1
SYSTEM MESSAGES
This message displays to indicate the result of Bad Call Notification.
➀ Bad Call Notification
1: XXXX XXXX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: 0000 0000 0000 0000
➀ ➁ ➂ ➃ ➄ ➅ ➆ ➇ ➈ ➉11
12
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b6 b5 b4 b3 b2 b1 b0
Default Alarm:
SUP6-HBad Call NotificationDefault Grade:
2Grade Modified: Lamp Modified:
b0-b3: Station...

Page 148

CHAPTER 3 NDA-24307
Page 120
Issue 1
SYSTEM MESSAGES
When type of connection is intra-Station connection
➁ ~ ➃ Station number (see table)
➄ Called station number
➅ ~ ➇ Called station number 
(See table)
➈ Time Slot Number of Link 1 Note 1
➉ Not used
 Time Slot Number of Link 2 Note 1
 Not used
Note 1:Station at which the operation was performed as shown in the figure below. b7 b6 b5 b4 b3 b2 b1 b0
b3 b2 b1 b0
b7 b6 b5 b4 b3 b2 b1 b0
b4-b7b0-b3
➁DC0 DC1
➂DC2 DC3
➃DC4 DC5
b0-b3: Number of digits for the...

Page 149

NDA-24307 CHAPTER 3
Page 121
Issue 1
SYSTEM MESSAGES
When type of connection is Trunk connection
➁ ~ ➃ Station number (See table)
➄ Remote Route No.
➅ Remote Route No.
➆ Called trunk No.
➇ Not used
➈ Time Slot Number of Link 1 Note 1
➉ Not used
 Time Slot Number of Link 2 Note 1
 Not used
Note 1:Station at which the operation was performed as shown below. b7 b6 b5 b4 b3 b2 b1 b0
b7 b6 b5 b4 b3 b2 b1 b0
b3 b2 b1 b0
b7 b6 b5 b4 b3 b2 b1 b0
b4-b7 b0-b3
➁DC0 DC1
➂DC2 DC3
➃DC4 DC5
b0-b5: Route No. (1-63)
b6:...

Page 150

CHAPTER 3 NDA-24307
Page 122
Issue 1
SYSTEM MESSAGES
When type of connection is ACD Trunk connection
➁ ACD Trouble Kind
Note 1:When“➁ (ACD Trouble Kind)” is 01 Hex:
➂ ~ ➅ Information on Calling Party
➆ ➇ Not Used
➈ ➉ Information on Calling Party
Refer to 
Information on Held Party or 3rd Station/Trunk in 3-Party Connection
Refer to 
Note 2:When“➁ (ACD Trouble Kind)” is 14 Hex:
➂ Issue of ACDP (First digit of decimal place)
➃ Issue of ACDP (Second digit of decimal place)
Note 3:When“➁ (ACD Trouble Kind)”...