Page 161
NDA-24307 CHAPTER 3 Page 133 Issue 1 SYSTEM MESSAGES This message displays when the SMDR output buffer usage rate has exceeded the value assigned to ASYD, SYS1, INDEX249. ➀ Detail Information (a) FS = 0, FE = 0/1 ➁ 1: XXXX XXXX 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ ➂ ➃ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 b0 Default Alarm: SUP6-OSMDR Output Buffer Overflow...
Page 162
CHAPTER 3 NDA-24307 Page 134 Issue 1 SYSTEM MESSAGES ➂ Buffer Usage Rate Assigned by ASYD, SYS1, INDEX249 ➃ Buffer Usage Rate Assigned by ASYD, SYS1, INDEX250 (b) FS = 1, FE = 0 ➁ ➂ Overflow Rate ➃ Overflow Rate b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b1 b0 b0 b7 b6 b5 b4 b0-b3: Units b4-b7: Tens b0-b3: Units b4-b7: Tens b0, b1: Fault Grade by ALMG command 00 = NON CONT 01 = SUP 10 = MN 11 = MJ b0: 0/1 = -/100% Overflow b4-b7: 1-9 = 10%-90% Overflow
Page 163
NDA-24307 CHAPTER 3 Page 135 Issue 1 SYSTEM MESSAGES (c) FS = 2, FE = 0 ➁ SMDR Group No. ➂ Port No. ➃ Not used (d) FS = 3, FE = 0 ➁ b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b3 b2 b1 b0 b0-b3: SMDR Group No. to which failure occurred b0-b7: Port No. allocated for SMDR Group to which failure occurred (0-7) b0-b3: SMDR Group No. to which failure occurred
Page 164
CHAPTER 3 NDA-24307 Page 136 Issue 1 SYSTEM MESSAGES This message displays when the SMDR output buffer usage rate has been lowered to less than the value assigned in the ASYD, SYS1, INDEX250 after the rate exceeds the value assigned by INDEX249. ➀ Detail Information 1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 Default...
Page 165
NDA-24307 CHAPTER 3 Page 137 Issue 1 SYSTEM MESSAGES This message displays after the office data is loaded and system initialization has executed. ➀ ➁ Load Status 1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b11 b9 b8 Default Alarm: NON7-ASystem Initialize With Data LoadDefault Grade: 3Grade...
Page 166
CHAPTER 3 NDA-24307 Page 138 Issue 1 SYSTEM MESSAGES Note 1: Phase 1 Restart is executed when initializing the system without disrupting the following two-way connections that have already been established: Basic two-way connections (STN-STN, STN-TRK, TRK-TRK) Fixed connections Two-way connections established on a Fusion link Note 2:The Number Sharing data load also affects the data load of Dual Station Calling Over-FCCS . For more details, see Chapter 6, Section 12.
Page 167
NDA-24307 CHAPTER 3 Page 139 Issue 1 SYSTEM MESSAGES This message displays when system initialization is activated. ➀ ➁ Details on Intialization Note 2 ➂ FPC No. Note 2 Note 1: Phase 1 Restart is executed when initializing the system without disrupting the following two-way connections that have already been established: Basic two-way connections (STN-STN, STN-TRK, TRK-TRK) Fixed connections Two-way connections established on a Fusion link Note 2:When the whole system is initialized via key...
Page 168
CHAPTER 3 NDA-24307 Page 140 Issue 1 SYSTEM MESSAGES This message displays when the MBR switch on the CPU Front Panel has been turned ON at the time of CPU changeover or speech path changeover. ➀ Self-CPU Restart Information ➁ Mate-CPU Restart Information 1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b5 b4 b3 b0 b7 b5 b4 b3 b0 Default...
Page 169
NDA-24307 CHAPTER 3 Page 141 Issue 1 SYSTEM MESSAGES This message displays when the MBR switch on the CPU Front Panel has been turned OFF at the time of CPU changeover or speech path changeover. ➀ Self-CPU Restart Information ➁ Mate-CPU Restart Information 1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b5 b4 b3 b0 b7 b5 b4 b3 b0 Default...
Page 170
CHAPTER 3 NDA-24307 Page 142 Issue 1 SYSTEM MESSAGES This message displays when the MBR switch on the TSW card has been turned ON at CPU changeover or speech path changeover. ➀ System Status of TSW Card 1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b0 Default Alarm: NON7-ETSW MBR Key Turn ONDefault Grade: 3Grade Modified: Lamp Modified: b0:...