NDA-24307 CHAPTER 3
Page 183
Issue 1
SYSTEM MESSAGES
This message displays when a clock down failure occurs in the CCH/DCH circuit card. When this message is
indicated, the related CCH/DCH card is placed into make-busy status
.
➀ Location of faulty CCH/DCH card
1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ 
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b6 b5 b4 b3 b2 b1 b0
Default...

Page 212

CHAPTER 3 NDA-24307
Page 184
Issue 1
SYSTEM MESSAGES
This message displays when C-level infinite loop of the Port Microprocessor (PM) in the CCH/DCH circuit
card has occurred
.
➀ Location of faulty CCH/DCH card
1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ 
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b6 b5 b4 b3 b2 b1 b0
Default Alarm:
SUP13-BCCH C-Level Infinite Loop Failure...

Page 213

NDA-24307 CHAPTER 3
Page 185
Issue 1
SYSTEM MESSAGES
This message displays when C-level infinite loop of the Port Microprocessor (PM) in the CCH/DCH circuit
card has occurred
.
➀ Location of faulty CCH/DCH card
1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ 
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b6 b5 b4 b3 b2 b1 b0
Default Alarm:
SUP13-CCCH C-Level Infinite Loop Failure...

Page 214

CHAPTER 3 NDA-24307
Page 186
Issue 1
SYSTEM MESSAGES
This message displays when a Port Microprocessor (PM) of the CCH/DCH card did not send an answer to the
CPU
.
➀ Location of faulty CCH/DCH card
1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ 
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b6 b5 b4 b3 b2 b1 b0
Default Alarm:
SUP13-DCCH Lock-Up Failure (Permanent)Default Grade:
3Grade...

Page 215

NDA-24307 CHAPTER 3
Page 187
Issue 1
SYSTEM MESSAGES
This message displays when a Port Microprocessor (PM) of the CCH/DCH card did not send an answer to the
CPU
.
➀ Location of faulty CCH/DCH card
1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ 
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b6 b5 b4 b3 b2 b1 b0
Default Alarm:
SUP13-ECCH Lock-Up Failure (Temporary)Default Grade:
1Grade...

Page 216

CHAPTER 3 NDA-24307
Page 188
Issue 1
SYSTEM MESSAGES
This message displays when B-level infinite loop of the Port Microprocessor (PM) in the CCH/DCH circuit
card has occurred
.
➀ Location of faulty CCH/DCH card
1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ 
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b6 b5 b4 b3 b2 b1 b0
Default Alarm:
SUP13-FCCH B-Level Infinite Loop Failure...

Page 217

NDA-24307 CHAPTER 3
Page 189
Issue 1
SYSTEM MESSAGES
This message displays when B-level infinite loop of the Port Microprocessor (PM) in the CCH/DCH circuit
card has occurred
.
➀ Location of faulty CCH/DCH card
1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ 
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b6 b5 b4 b3 b2 b1 b0
Default Alarm:
SUP13-GCCH B-Level Infinite Loop Failure...

Page 218

CHAPTER 3 NDA-24307
Page 190
Issue 1
SYSTEM MESSAGES
This message displays when a failure has occurred numerous times to a common channel signaling link and
the link has been placed into make-busy state
.
➀ Location of Faulty CCH/DCH Card
➁ Data to be Analyzed by NEC 
Engineers
1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁ ➂
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b6 b5 b4 b3 b2...

Page 219

NDA-24307 CHAPTER 3
Page 191
Issue 1
SYSTEM MESSAGES
➂ Probable cause for the failure
b3 b2 b1 b0b0-b3: See Table:
FLT IDCCITT 
ERROR FA C TO R
00 A S (F = 1) frame is received.
01 B DM (F = 1) response is received.
02 C UA (F = 1) response is received.
03 D UA (F = 0) response is received.
04 E DM (F = 0) response is received.
05 F SABME command is received.
06 G N200 Timeout (Link is set)
07 HN200 Timeout (Link is 
disconnected)
08 IN200 Timeout (Link failure is 
restored to normal)
09 J N (R) frame...

Page 220

CHAPTER 3 NDA-24307
Page 192
Issue 1
SYSTEM MESSAGES
This message displays when a failure has occurred numerous times to a common channel signaling link and
the link has been placed into make-busy state. When this fault lasts over three minutes, the system message
changes to [13-H] CCS Link Failure (Permanent)
.
➀ Location of faulty CCH/DCH card
➁ Data to be Analyzed by NEC Engineers
1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁ ➂
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000...