NEC Neax 2400 Ipx System Operations And Maintenance Manual
Here you can view all the pages of manual NEC Neax 2400 Ipx System Operations And Maintenance Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 211
NDA-24307 CHAPTER 3 Page 183 Issue 1 SYSTEM MESSAGES This message displays when a clock down failure occurs in the CCH/DCH circuit card. When this message is indicated, the related CCH/DCH card is placed into make-busy status . ➀ Location of faulty CCH/DCH card 1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 Default...
Page 212
CHAPTER 3 NDA-24307 Page 184 Issue 1 SYSTEM MESSAGES This message displays when C-level infinite loop of the Port Microprocessor (PM) in the CCH/DCH circuit card has occurred . ➀ Location of faulty CCH/DCH card 1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 Default Alarm: SUP13-BCCH C-Level Infinite Loop Failure...
Page 213
NDA-24307 CHAPTER 3 Page 185 Issue 1 SYSTEM MESSAGES This message displays when C-level infinite loop of the Port Microprocessor (PM) in the CCH/DCH circuit card has occurred . ➀ Location of faulty CCH/DCH card 1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 Default Alarm: SUP13-CCCH C-Level Infinite Loop Failure...
Page 214
CHAPTER 3 NDA-24307 Page 186 Issue 1 SYSTEM MESSAGES This message displays when a Port Microprocessor (PM) of the CCH/DCH card did not send an answer to the CPU . ➀ Location of faulty CCH/DCH card 1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 Default Alarm: SUP13-DCCH Lock-Up Failure (Permanent)Default Grade: 3Grade...
Page 215
NDA-24307 CHAPTER 3 Page 187 Issue 1 SYSTEM MESSAGES This message displays when a Port Microprocessor (PM) of the CCH/DCH card did not send an answer to the CPU . ➀ Location of faulty CCH/DCH card 1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 Default Alarm: SUP13-ECCH Lock-Up Failure (Temporary)Default Grade: 1Grade...
Page 216
CHAPTER 3 NDA-24307 Page 188 Issue 1 SYSTEM MESSAGES This message displays when B-level infinite loop of the Port Microprocessor (PM) in the CCH/DCH circuit card has occurred . ➀ Location of faulty CCH/DCH card 1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 Default Alarm: SUP13-FCCH B-Level Infinite Loop Failure...
Page 217
NDA-24307 CHAPTER 3 Page 189 Issue 1 SYSTEM MESSAGES This message displays when B-level infinite loop of the Port Microprocessor (PM) in the CCH/DCH circuit card has occurred . ➀ Location of faulty CCH/DCH card 1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 Default Alarm: SUP13-GCCH B-Level Infinite Loop Failure...
Page 218
CHAPTER 3 NDA-24307 Page 190 Issue 1 SYSTEM MESSAGES This message displays when a failure has occurred numerous times to a common channel signaling link and the link has been placed into make-busy state . ➀ Location of Faulty CCH/DCH Card ➁ Data to be Analyzed by NEC Engineers 1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ ➂ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2...
Page 219
NDA-24307 CHAPTER 3 Page 191 Issue 1 SYSTEM MESSAGES ➂ Probable cause for the failure b3 b2 b1 b0b0-b3: See Table: FLT IDCCITT ERROR FA C TO R 00 A S (F = 1) frame is received. 01 B DM (F = 1) response is received. 02 C UA (F = 1) response is received. 03 D UA (F = 0) response is received. 04 E DM (F = 0) response is received. 05 F SABME command is received. 06 G N200 Timeout (Link is set) 07 HN200 Timeout (Link is disconnected) 08 IN200 Timeout (Link failure is restored to normal) 09 J N (R) frame...
Page 220
CHAPTER 3 NDA-24307 Page 192 Issue 1 SYSTEM MESSAGES This message displays when a failure has occurred numerous times to a common channel signaling link and the link has been placed into make-busy state. When this fault lasts over three minutes, the system message changes to [13-H] CCS Link Failure (Permanent) . ➀ Location of faulty CCH/DCH card ➁ Data to be Analyzed by NEC Engineers 1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ ➂ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000...