NDA-24307 CHAPTER 3
Page 233
Issue 1
SYSTEM MESSAGES
➂ Day/Night Mode Specification
➃ External Switch Status b7 b6 b5 b4 b3 b2 b1 b0
b7 b6 b5 b4 b3 b2 b1 b0
b0-b3:  Mode after changing (Refer to table below)
b4-b7:  Mode before changing (Refer to table below)
Note:
This data is programmed as initial data.
b0b1b2b3
MEANING
b4b5b6b7
0000Day Mode
0 0 0 1 Night Mode 1
0 0 1 0 Night Mode 2 (available only for Japan)
0011Night Mode 3 (DIT-Night Connection Fixed) 
Note
b0-b7:
01=Not used
02=Day/Night Change...

Page 262

CHAPTER 3 NDA-24307
Page 234
Issue 1
SYSTEM MESSAGES
This message displays when the MB switch on the IOC card has turned ON when extracting or inserting a
circuit card.
➀ Circuit Card No.
1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ 
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b0
Default Alarm:
NON17-OIOC MB Key Turn ONDefault Grade:
3Grade Modified: Lamp Modified:
b0: 0/1 = IOC 0/IOC 1 

Page 263

NDA-24307 CHAPTER 3
Page 235
Issue 1
SYSTEM MESSAGES
This message displays when the MB switch on the IOC card has turned OFF.
➀ Circuit Card No.
1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ 
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b0
Default Alarm:
NON17-PIOC MB Key Turn OFFDefault Grade:
3Grade Modified: Lamp Modified:
b0: 0/1 = IOC 0/IOC 1 

Page 264

CHAPTER 3 NDA-24307
Page 236
Issue 1
SYSTEM MESSAGES
This message displays when the MBR switch on the IOC card has turned ON at the time of CPU changeover
or speech path changeover.
➀ Circuit Card No.
1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ 
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b0
Default Alarm:
NON17-QIOC MBR Key Turn ONDefault Grade:
3Grade Modified: Lamp Modified:
b0: 0/1...

Page 265

NDA-24307 CHAPTER 3
Page 237
Issue 1
SYSTEM MESSAGES
This message displays when the MBR switch on the IOC card has turned OFF at the time of CPU changeover
or speech path changeover.
➀ Circuit Card No.
1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ 
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b0
Default Alarm:
NON17-RIOC MBR Key Turn OFFDefault Grade:
3Grade Modified: Lamp Modified:
b0:...

Page 266

CHAPTER 3 NDA-24307
Page 238
Issue 1
SYSTEM MESSAGES
This message displays when the MBR switch on the IOGT (PH-GT10) card in ISW is turned ON.
➀ IOGT card system status
➁ IOGT card system status after key 
operation
Note 1:If the MBR key on the active IOGT card is flipped, the ACT/STBY of Speech Path Systems within the
whole system is totally changed over. For more details, refer to Chapter 6, Chapter 12.
Note 2:“1” is always displayed in the bit data.
1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3:...

Page 267

NDA-24307 CHAPTER 3
Page 239
Issue 1
SYSTEM MESSAGES
This message displays when the MBR switch on the IOGT (PH-GT10) card in ISW is turned OFF.
➀ IOGT card system status
➁ IOGT card system status after key 
operation
Note:If failure occurs on the HSW card side, the IOGT card is placed in Make-Busy state and “1” is
displayed in the bit. Otherwise, “0” is displayed.
1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000...

Page 268

CHAPTER 3 NDA-24307
Page 240
Issue 1
SYSTEM MESSAGES
This message displays when the Primary Dch fails, Dch Back-Up function is operated automatically.
➀ Condition of the Dch
➁ Location of the Dch (Primary)
➂ Location of the Dch (Back-up)
1: XXXX XXXX XXXX 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁ ➂ ➃ ➄ ➅
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b6 b5 b4 b3 b2 b1 b0
b7 b6 b5 b4 b3 b2 b1 b0
b7...

Page 269

NDA-24307 CHAPTER 3
Page 241
Issue 1
SYSTEM MESSAGES
➃ Changeover Information
➄ Status of the Primary/Back-up Dch
➅ EVENT No.b3 b2 b1 b0
b5 b4 b3 b2 b1 b0
b7 b6 b5 b4 b3 b2 b1 b0
b0, b1:
00 = Change from Primary Dch to Dch for Back-up
01 = Change from Dch for Back-up to Primary Dch
10 = Place Primary Dch to ACT status
11 = Place Dch for Back-up to ACT status
b2, b3:
00 = Change signal is received
01 = Change signal is sent
b0-b2: Status of Primary Dch
0 = In service (ACT status)
1 = STBY
2 = Out of...

Page 270

CHAPTER 3 NDA-24307
Page 242
Issue 1
SYSTEM MESSAGES
This message displays when the Primary Dch fails, and the Dch Back-Up function is operated manually.
➀ Condition of the Dch
➁ Location of the Dch (Primary)
➂ Location of the Dch (Back-up)
1: XXXX XXXX XXXX 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁ ➂ ➃ ➄ ➅
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b6 b5 b4 b3 b2 b1 b0
b7 b6 b5 b4 b3 b2 b1 b0...