NDA-24307 CHAPTER 3
Page 263
Issue 1
SYSTEM MESSAGES
This message displays when a grave failure occurs on the SDT (PA-SDTA/B) card. If this is issued, remember
the ACT/STBY change of the SDT card may be followed, as a result of fault detection in the optical fiber line
(see [33-E] message).
➀ MG (Module Group)
➁ Details on alarm
Note:Fault repair procedure on each alarm is shown on the next page.
1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁
4: 0000 0000 0000 0000 5: 0000 0000...

Page 292

CHAPTER 3 NDA-24307
Page 264
Issue 1
SYSTEM MESSAGES
Repair Procedure
Depending on the fault status shown in data 
➁, perform necessary repair work:
(1) Hardware Failure/Onboard Power Alarm
SDT (PA-SDTA/B) card is faulty. Replace the card with a spare by referring to Chapter 4, Section 3.3.3,
SDT Card Replacement Procedure.
(2) Optical Line Failure
Diagnosis: In addition to this alarm, is the “PCM Loss” alarm also indicated?
YES→Optical line side is faulty.
Verify that the SDT card in the distant node is...

Page 293

NDA-24307 CHAPTER 3
Page 265
Issue 1
SYSTEM MESSAGES
(6) Receiving Path Failure/Receiving Path Error
Abnormal state is detected in the process of multiplexing the “Receive” signals. To restore this, perform
the following:
STEP 1 Initialization of SDT card (distant node)
Initialize the SDT card in the distant node, and observe the situation. If the fault is not restored,
proceed with STEP 2.
STEP 2 Initialization of SDT card (self-node)
Initialize the SDT card in the self-node, and observe the situation....

Page 294

CHAPTER 3 NDA-24307
Page 266
Issue 1
SYSTEM MESSAGES
This message displays when the SDT (PA-SDTA/B) card or optical fiber line, which was once detected as
faulty, recovers.
➀ MG (Module Group)
➁ Details on the fault
1: X0XX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b0
b7 b4 b3 b2 b1 b0
Default Alarm:
NON33-DSDT Alarm RestoreDefault Grade:...

Page 295

NDA-24307 CHAPTER 3
Page 267
Issue 1
SYSTEM MESSAGES
This message displays when the ACT/STBY of the SDT (PA-SDTA) card is changed over as a result of fault
detection in the optical fiber line. When the ACT/STBY change cannot be performed, this message also
indicates the cause for the changeover execution failure.
➀ MG (Module Group)
➁ Detailed information
➂ Cause for changeover execution failure
Repair Procedure
Once this message displays, be sure to check other messages, such as [33-C] SDT Alarm...

Page 296

CHAPTER 3 NDA-24307
Page 268
Issue 1
This page is for your notes. 

Page 297

NDA-24307 CHAPTER 4
Page 269
Issue 1
CHAPTER 4 UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE
1. LPM ACCOMMODATING UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE
This section explains how to replace unit/circuit cards mounted in the LPM (ISW/IMG 0).
1.1 Precautions
Use this procedure to replace a faulty unit/circuit card with a spare or to check a spare card.
There are functional switches (having set the default switch) on some of the circuit cards to be replaced.
As for switch setting on the circuit cards, confirm...

Page 298

CHAPTER 4 NDA-24307
Page 270
Issue 1
UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE
Figure 4-1   Circuit Card Mounting Face Layout of LPM
12
34
567
8
OFF
12
34
567
8
OFF
12
34
OFF
MBR
FDD ON
OFF
PALM
ON
OFF OUT PWR
IN PWR5AHDD SW
MB
SYSTEM SELECT0
SENSE SYSTEM SELECT1
SYSTEM SELECT2
CPURST
SLOT No.    0 1 2 3 4 5 6 STATUS IMG1 IMG2 IMG3 CPUOPE
WDTIMG0
ON
ON
ON4C026AE
12
34
567
8
OFF
12
34
567
8
OFF
12
34
OFF
MBR
FDD ON
OFF
ON
OFF OUT PWR
IN PWR5AHDD SW
MB
SYSTEM SELECT0
SENSE SYSTEM SELECT1
SYSTEM SELECT2...

Page 299

NDA-24307 CHAPTER 4
Page 271
Issue 1
UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE
1.3 Operating Procedures
The following paragraphs provide operating procedures to replace unit/circuit cards of the LPM. Perform
the operations that correspond to each reference item specified in Ta b l e  4 - 1.
Table 4-1  LPM Unit/Circuit Cards and Reference Items
UNIT/CIRCUIT CARD REFERENCE ITEM REMARKS
CPRSection 1.3.1, CPR Replacement ProcedureCPU, ISAGT, 
LANI, HFD
EMA CardSection 1.3.2, EMA Card Replacement Procedure
IOC...

Page 300

CHAPTER 4 NDA-24307
Page 272
Issue 1
UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE
1.3.1 CPR Replacement Procedure
This section explains how to replace the Control Processor Rack (CPR). The CPR
is mounted in IMG 0 of LN and ISW. Before starting the procedures, make a backup
copy of the main data, such as office data, Call Forwarding (CF) data and Speed
Calling (SPD) data, on to the hard disk of the HFD. Figure 4-2 shows the front view
of the CPR. Operate the related keys and connectors to replace the CPU with...