Page 311
NDA-24307 CHAPTER 4 Page 283 Issue 1 UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE (5) Insert the new HFD (PZ-IO27) into the CPR. Then, fasten the two screws as shown in Figure 4-8. Figure 4-8 Insertion of New HFD Into CPR ATTENTIONContents Static Sensitive Handling Precautions Required LPM HFD (PZ-IO27/PZ-IO28)
Page 312
CHAPTER 4 NDA-24307 Page 284 Issue 1 UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE (6) Make sure Switch 8 of SYSTEM SELECT 1 (DIP Switch) on each CPU Front Panel is set to ON. (Do this for all LNs and ISW: Refer to Figure 4-9.) Figure 4-9 Switch Setting on the CPU Front Panel ATTENTIONContents Static Sensitive Handling Precautions Required 12 34 567 8 OFF 12 34 OFF MBR FDD ON OFF PALM ON OFF OUT PWR IN PWR5AHDD SW MB SYSTEM SELECT0 SENSE SYSTEM SELECT2 CPURST SLOT No. 0 1 2 3 4 5 6 STATUS IMG1 IMG2 IMG3...
Page 313
NDA-24307 CHAPTER 4 Page 285 Issue 1 UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE 1.3.2 EMA Card Replacement Procedure The EMA (PH-PC40) card is mounted in slot No. 04 of the LPM. The main functions of the card are as follows: Designation of ACT/STBY status of the CPU and forced changeover of the system Shutoff of the system’s power supply and detection of rising temperature within the system Control of the NCU (PA-M53) card Replacement Procedure ATTENTIONContents Static Sensitive Handling Precautions...
Page 314
CHAPTER 4 NDA-24307 Page 286 Issue 1 UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE ATTENTIONContents Static Sensitive Handling Precautions Required OPE/MB Lamp on the EMA card lights steady-green. The PFT service is cancelled: resumption of normal operation. Turn ON the MB and EMA SUP keys on the new card. Turn OFF the MB and EMA SUP keys on the card. Assign the time data by using the ATIM/ATIMN END A Set the keys on the new card by referring to the Insert the new card into the LPM.card being replaced....
Page 315
NDA-24307 CHAPTER 4 Page 287 Issue 1 UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE 1.3.3 IOC Card Replacement Procedure The IOC (PH-IO24) card is mounted in slot No. 02 and/or 03 of the LPM. The card’s main function is to provide a serial interface between the system and its external equipment, such as the Maintenance Administration Terminal (MAT), Station Message Detail Recording System (SMDR), Message Center Interface (MCI), Property Management System (PMS), etc. AT T E N T I O NContents Static Sensitive...
Page 316
CHAPTER 4 NDA-24307 Page 288 Issue 1 UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE ATTENTIONContents Static Sensitive Handling Precautions Required OPE lamp on the IOC card lights red. Release of I/O ports: new IOC card is initialized, and I/O port channels reopens. OPE lamp lights green. Turn OFF the MB key on the card. END Insert the new card into the LPM. Turn ON the MB and MBR keys on the new card. Turn OFF the MBR key on the card. A
Page 317
NDA-24307 CHAPTER 4 Page 289 Issue 1 UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE 1.3.4 Power Supply Unit Replacement Procedure ATTENTIONContents Static Sensitive Handling Precautions Required CPU System Changeover Refer to Section 12, Chapter 6. Cable to be disconnected from OUTPWR CPU 0: 6P-(4P-3P) PWR CA-A CPU 1: 6P-(4P-3P) PWR CA-B START Set the mode of the PWR UNIT (PZ-PW92) to be replaced into STBY mode. On the EMA (PH-PC40) card, set EMA SUP switch UP. Turn OFF the SW key on the PWR UNIT. Disconnect...
Page 318
CHAPTER 4 NDA-24307 Page 290 Issue 1 UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE ATTENTIONContents Static Sensitive Handling Precautions Required END Insert the new PWR UNIT into the CPR. Unscrew the PWR UNIT from the CPR. Turn ON the SW key on the PWR UNIT. A On the EMA card, set EMA SUP switch DOWN. Reattach power alarm cable to the PALM connector on the PZ-PW92.Reattach power cables to OUTPWR and INPWR connectors on the PZ-PW92.
Page 319
NDA-24307 CHAPTER 4 Page 291 Issue 1 UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE 1.3.5 MISC Card Replacement Procedure ATTENTIONContents Static Sensitive Handling Precautions Required Keep MB switch UP. END Extract the MISC card from its mounting slot. On the MISC card, set MB switch UP. On the MISC card, set MB switch DOWN. START Insert the new circuit card into the same mounting slot.
Page 320
CHAPTER 4 NDA-24307 Page 292 Issue 1 UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE 1.3.6 MMC Card Replacement Procedure The MMC (PH-M22) card is mounted in slot No. 00 of the LPM. The card’s main functions are: To collect key setting information on the TOPU of each LN/ISW. Note To collect alarm information on LN or the entire system (in case of MMC in ISW), thereby activating MJ/MN LED on the TOPU display. Note:If the key setting affects the entire system (i.e. the SYSTEM side is selected by the INITIAL...