Page 281
NDA-24307 CHAPTER 3 Page 253 Issue 1 SYSTEM MESSAGES Application Type [When =03 (SMDR) / 04 (MCI) ] Device Number of Error-detected client PC Kind of Error Details on Detected Error ~ Not used b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 9b0-b7 : (Hex) 01=SUPER SERVER 02=MAT 03=SMDR 04=MCI 05=OAI 06=PMS 07=MIS 9 10b0-b7: (Hex) Device Number of error-detected Client PC. If the Machine Number is not determined, “FF” is output. b0-b7: (Hex) 01=SEND...
Page 282
CHAPTER 3 NDA-24307 Page 254 Issue 1 SYSTEM MESSAGES When =05 (OAI) / 07 (MIS) Faulty Logical Port No. (Hex) Error Kind (ERRK) Not used b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 Table 3-3 Error Kind (ERRK) Output Data Error Situation Required Check 01HSEND Execution Error TCP/IP connection is down because the text is not transmit- ted continuously.[1] Check the TCP/IP Transmission capacity on the UAP side is proper or not. [2] Check the operation status on the UAP side is normal....
Page 283
NDA-24307 CHAPTER 3 Page 255 Issue 1 SYSTEM MESSAGES This message is issued when the LAN Interface Connection Failure, detected in Message [26-V], recovers. This message is displayed when the LAN Interface Connection Failure is restored, and then the first data is normally sent/received by the recovered application equipment. ~ IP Address for external equipment in which error has been detected. (Hex.) , Port No. (Client Port No.) (Hex.) Socket No. (Used Socket No.) (Hex.) Error Code (TCP/IP Error...
Page 284
CHAPTER 3 NDA-24307 Page 256 Issue 1 SYSTEM MESSAGES Application Type When =03 (SMDR) / 04 (MCI) Device Number of recovered client PC Recovery Information b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 9b0-b7 : (Hex) 01=SUPER SERVER 02=MAT 03=SMDR 04=MCI 05=OAI 06=PMS 07=MIS 9 10b0-b7: (Hex) Device Number of recovered Client PC for external LAN Interface. b0-b7: (Hex) 01=Recovered 02~FF=Not defined 11
Page 285
NDA-24307 CHAPTER 3 Page 257 Issue 1 SYSTEM MESSAGES This message is issued when the MBR switch on the DLMX card has been turned ON at the time of DLMX ACT/ST-BY changeover, etc. ➀ Location of the DLMX card ➁ System status of DLMX card 1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 b7 b1 b0 Default Alarm: NON27-EDLMX...
Page 286
CHAPTER 3 NDA-24307 Page 258 Issue 1 SYSTEM MESSAGES This message is issued when the MBR switch on the DLMX card has been turned OFF at the time of DLMX ACT/ST-BY changeover, etc. ➀ Location of the DLMX card ➁ System status of DLMX card 1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 b7 b1 b0 Default Alarm: NON27-FDLMX...
Page 287
NDA-24307 CHAPTER 3 Page 259 Issue 1 SYSTEM MESSAGES This message is issued when a DLMX card is placed to ACT state due to a mode changeover. ➀ Reason for changeover 1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b2 b1 b0 Default Alarm: NON27-GDLMX ACT Change ReportDefault Grade: 3Grade Modified: Lamp Modified: b2 b1 b0 0 0 0 = MBR key...
Page 288
CHAPTER 3 NDA-24307 Page 260 Issue 1 SYSTEM MESSAGES This message displays when the MUX (PH-PC36) card, whose clock function was detected as faulty, is recovered. ➀ MUX Card Location and System Status ➁ RLS Data 1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b4 b3 b2 b1 b0 b3 b2 b1 Default Alarm: NON33-AMUX Clock RestoreDefault Grade: 3Grade...
Page 289
NDA-24307 CHAPTER 3 Page 261 Issue 1 SYSTEM MESSAGES This message displays when an abnormal state is detected temporarily on the SDT (PA-SDTA/B) card. ➀ MG (Module Group) ➁ Details on alarm Note:Alarm-detected HW is specified in ➂ (next page). 1: X0XX 00XX XXXX XX00 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ ➂ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b0 b7 b4 b3 b2 b1 b0 Default Alarm: SUP33-BSDT...
Page 290
CHAPTER 3 NDA-24307 Page 262 Issue 1 SYSTEM MESSAGES ➂ Alarm-detected HW Note:This data displays only when b4 is “1” and b3 is “0” in data ➁. Repair Procedure Basically, fault repair work is not required by the display of this message. However, if the message is created frequently, it is recommended that the repair work be performed as shown in the message [33-C] SDT Alarm Trouble. b7 b6 b5 b4 b3 b2 b1 b0 The data here specifies the HW, on which any of the VC-11 Path Trouble was detected in data ➁ (see...