NDA-24307 CHAPTER 3
Page 253
Issue 1
SYSTEM MESSAGES
 Application Type
[When  =03 (SMDR) / 04 (MCI) ]
 Device Number of Error-detected client PC
 Kind of Error
 Details on Detected Error
~ Not used
b7 b6 b5 b4 b3 b2 b1 b0
b7 b6 b5 b4 b3 b2 b1 b0
b7 b6 b5 b4 b3 b2 b1 b0
b7 b6 b5 b4 b3 b2 b1 b0
9b0-b7 : (Hex)
01=SUPER SERVER
02=MAT
03=SMDR
04=MCI
05=OAI
06=PMS
07=MIS
9
10b0-b7: (Hex)
Device Number of error-detected Client PC. 
If the Machine Number is not determined, “FF”
is output.
b0-b7: (Hex)
01=SEND...

Page 282

CHAPTER 3 NDA-24307
Page 254
Issue 1
SYSTEM MESSAGES
When  =05 (OAI) / 07 (MIS) 
 Faulty Logical Port No. (Hex)
 Error Kind (ERRK)
 Not used b7 b6 b5 b4 b3 b2 b1 b0
b7 b6 b5 b4 b3 b2 b1 b0
Table 3-3  Error Kind (ERRK)
Output Data Error Situation Required Check
01HSEND Execution Error
TCP/IP connection is down because the text is not transmit-
ted continuously.[1] Check the TCP/IP Transmission 
capacity on the UAP side is proper or 
not.
[2] Check the operation status on the 
UAP side is normal....

Page 283

NDA-24307 CHAPTER 3
Page 255
Issue 1
SYSTEM MESSAGES
This message is issued when the LAN Interface Connection Failure, detected in Message [26-V], recovers.
This message is displayed when the LAN Interface Connection Failure is restored, and then the first data is
normally sent/received by the recovered application equipment.
~  IP Address for external equipment in which error has been detected. (Hex.)
,
  Port No. (Client Port No.) (Hex.)
 Socket No. (Used Socket No.) (Hex.)
 Error Code (TCP/IP Error...

Page 284

CHAPTER 3 NDA-24307
Page 256
Issue 1
SYSTEM MESSAGES
 Application Type
When =03 (SMDR) / 04 (MCI) 
 Device Number of recovered client PC
 Recovery Information
b7 b6 b5 b4 b3 b2 b1 b0
b7 b6 b5 b4 b3 b2 b1 b0
b7 b6 b5 b4 b3 b2 b1 b0
9b0-b7 : (Hex)
01=SUPER SERVER
02=MAT
03=SMDR
04=MCI
05=OAI
06=PMS
07=MIS
9
10b0-b7: (Hex)
Device Number of recovered Client PC 
for external LAN Interface.
b0-b7: (Hex)
01=Recovered
02~FF=Not defined
11 

Page 285

NDA-24307 CHAPTER 3
Page 257
Issue 1
SYSTEM MESSAGES
This message is issued when the MBR switch on the DLMX card has been turned ON at the time of DLMX
ACT/ST-BY changeover, etc.
➀ Location of the DLMX card
➁ System status of DLMX card
1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b6 b5 b4 b3 b2 b1 b0
b7 b1 b0
Default Alarm:
NON27-EDLMX...

Page 286

CHAPTER 3 NDA-24307
Page 258
Issue 1
SYSTEM MESSAGES
This message is issued when the MBR switch on the DLMX card has been turned OFF at the time of DLMX
ACT/ST-BY changeover, etc.
➀ Location of the DLMX card
➁ System status of DLMX card
1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b6 b5 b4 b3 b2 b1 b0
b7 b1 b0
Default Alarm:
NON27-FDLMX...

Page 287

NDA-24307 CHAPTER 3
Page 259
Issue 1
SYSTEM MESSAGES
This message is issued when a DLMX card is placed to ACT state due to a mode changeover.
➀ Reason for changeover
1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ 
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b2 b1 b0
Default Alarm:
NON27-GDLMX ACT Change ReportDefault Grade:
3Grade Modified: Lamp Modified:
b2 b1 b0
0 0 0 = MBR key...

Page 288

CHAPTER 3 NDA-24307
Page 260
Issue 1
SYSTEM MESSAGES
This message displays when the MUX (PH-PC36) card, whose clock function was detected as faulty, is
recovered.
➀ MUX Card Location and System 
Status
➁ RLS Data
1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b4 b3 b2 b1 b0
b3 b2 b1
Default Alarm:
NON33-AMUX Clock RestoreDefault Grade:
3Grade...

Page 289

NDA-24307 CHAPTER 3
Page 261
Issue 1
SYSTEM MESSAGES
This message displays when an abnormal state is detected temporarily on the SDT (PA-SDTA/B) card.
➀ MG (Module Group)
➁ Details on alarm
Note:Alarm-detected HW is specified in ➂ (next page).
1: X0XX 00XX XXXX XX00 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
➀ ➁ ➂
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b0
b7 b4 b3 b2 b1 b0
Default Alarm:
SUP33-BSDT...

Page 290

CHAPTER 3 NDA-24307
Page 262
Issue 1
SYSTEM MESSAGES
➂ Alarm-detected HW
Note:This data displays only when b4 is “1” and b3 is “0” in data ➁.
Repair Procedure
Basically, fault repair work is not required by the display of this message. However, if the message is created
frequently, it is recommended that the repair work be performed as shown in the message [33-C] SDT Alarm
Trouble. b7 b6 b5 b4 b3 b2 b1 b0
The data here specifies the HW, on which any of the VC-11 Path 
Trouble was detected in data 
➁ (see...