Page 361

NDA-24307 CHAPTER 4
Page 333
Issue 1
UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE
4.3.1 IOGT Card Replacement Procedure
The IOGT (PH-GT10) card is mounted in Slot No. 10 or 11 within the ISWM. This card provides
MISC/TSW I/O bus interfaces between the CPU and TSW, HSW, PLO cards within the ISWM. Figure
4-16 shows a system block diagram centering upon the CPU and it’s controlling IOGT. If the ACT/
STBY of IOGT is changed over, those of TSW, HSW (in ISW) and TSW, MUX, DLKC (in all LNs)
are also totally changed...

Page 362

CHAPTER 4 NDA-24307
Page 334
Issue 1
UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE
IOGT Card Replacement Procedure
Use extreme care when operating the keys on the DSP of CPR and PH-GT09 card.
WAR NI NG
ATTENTIONContents
Static Sensitive
Handling
Precautions Required
System Changeover: Check the following
lamp indications on the IOGT and other
circuit cards in the same Switching block
and ensure they are all OFF:
At the ISW:
TSW ACT (IOGT cards)
TSW ACT (TSW cards)
HSW ACT (HSW cards)
At the LN:
TSW ACT...

Page 363

NDA-24307 CHAPTER 4
Page 335
Issue 1
UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE
ATTENTIONContents
Static Sensitive
Handling
Precautions Required
TSW ACT lamp on the IOGT card 
lights red.
TSW ACT lamp on the new card 
lights red.
TSW ACT lamp on the IOGT card 
goes OFF.
TSW ACT lamp on the IOGT card 
goes OFF.
B
Insert the new card into the ISWM.
A
Set the MBR key on the new card DOWN.
Set the MB key on the new card DOWN.Extract the IOGT card to be replaced 
from the ISWM.
On the new IOGT card, set the...

Page 364

CHAPTER 4 NDA-24307
Page 336
Issue 1
UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE
Note:
The system changeover of Speech Path system can be executed also by using the CMODI command. For
details, refer to Chapter 8, Maintenance Commands.
System Changeover: Check the following lamp
indications on the IOGT and other circuit cards
in the same Switching block are all steady
green:
At the ISW:
TSW ACT (IOGT cards)
TSW ACT (TSW cards)
HSW ACT (HSW cards)
At the LN:
TSW ACT (TSW cards)
OPE/MB (DLKC card)
MUX ACT...

Page 365

NDA-24307 CHAPTER 4
Page 337
Issue 1
UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE
4.3.2 TSW Card Replacement Procedure
The TSW (PH-SW00) card is mounted in the Slot Nos. ranging from 04 to 07 and Slot Nos. 14 to 17
within the ISWM. Equipped with the Time Division Switch (TSW) and INT function, each circuit card
provides Time Slot (TS) switching for one Local Node (LN). In addition, used together with two PU-
SW01 (HSW) cards in pair, four PU-SW00 (TSW) cards achieve a maximum of 32,768 TS switching
for four...

Page 366

CHAPTER 4 NDA-24307
Page 338
Issue 1
UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE
TSW ACT lamp on the TSW card 
lights red.
TSW ACT lamp on the TSW card 
goes OFF.
TSW ACT lamp on the TSW card 
goes OFF.
ATTENTIONContents
Static Sensitive
Handling
Precautions Required
B
A
Set the TSW MB key on the new card DOWN.Insert the new card into the ISWM.
Set the TSW MBR and TSW MB keys on the
new card UP. Extract the TSW card from the ISWM.
Set the key on the new card, referring to 
the card replaced.
Confirm...

Page 367

NDA-24307 CHAPTER 4
Page 339
Issue 1
UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE
Note:
The system changeover of Speech Path system can be executed also by using the CMODI command. For
details, refer to Chapter 8, Maintenance Commands.
ATTENTIONContents
Static Sensitive
Handling
Precautions Required
System Changeover: Check the following
lamp indications on the TSW and other
circuit cards in the same Switching block
are all steady green:
At the ISW:
TSW ACT (IOGT cards)
TSW ACT (TSW cards)
HSW ACT (HSW...

Page 368

CHAPTER 4 NDA-24307
Page 340
Issue 1
UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE
4.3.3 HSW Card Replacement Procedure
The HSW (PH-SW01) card is mounted in the Slot Nos. 03, 04 and Slot Nos. 18 and 19. The main
functions of this card are as follows:
(a) The swithc omposition is T-T-S-T (T:Time division, S: Space division, T: Time division), and the
space division is composed with this circuit card.
(b) This circuit card collects the 16 highways of PCM data from TSW cards and sends 8 highways to
TSW cards by...

Page 369

NDA-24307 CHAPTER 4
Page 341
Issue 1
UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE
HSW ACT lamp on the HSW card 
lights red.
HSW ACT lamp on the HSW card 
goes OFF.
HSW ACT lamp on the HSW card 
goes OFF.
ATTENTIONContents
Static Sensitive
Handling
Precautions Required
B
A
Set the HSW MB keys on the new card DOWN.Insert the new card into the ISWM. Set the HSW MB keys on the new card UP.Extract the HSW card from the ISWM.
On the HSW card to be replaced, set the
MB key UP. 

Page 370

CHAPTER 4 NDA-24307
Page 342
Issue 1
UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE
Note:
The system changeover of Speech Path system can be executed also by using the CMODI command. For
details, refer to Chapter 8, Maintenance Commands.
ATTENTIONContents
Static Sensitive
Handling
Precautions Required
System Changeover: Check the following
lamp indications on the TSW and other
circuit cards in the same Switching block
are all steady green:
At the ISW:
TSW ACT (IOGT cards)
TSW ACT (TSW cards)
HSW ACT (HSW...