Page 401
NDA-24307 CHAPTER 5 Page 373 Issue 1 FAULT REPAIR PROCEDURES Table 5-4 Timings for Trunks ITEMS FOR STATUS SUPERVISIONCONDITIONS FOR SUPERVISION TIMING SPECIFICATIONS 1 Detection of Call TerminationRing Down System Detection by ringing signal (20Hz) from the opposite office. Loop System Detection by loop from the opposite office. E&M System Detection by incoming signal (ground or –48V) on E (RG2) lead.Ringing signal of more than four cycles is detected within 800 ms. Detection within 16 ms after...
Page 402
CHAPTER 5 NDA-24307 Page 374 Issue 1 FAULT REPAIR PROCEDURES Table 5-5 Timings for Senders ITEMS FOR STATUS SUPERVISIONCONDITIONS FOR SUPERVISION TIMING SPECIFICATIONS 1 Sender Acknowledge Wait Ti merTiming limit for waiting to receive connection acknowledgement signal from the opposite office after seizing the opposite office.4 sec. (standard) Timing can be assigned using ASYD SYS 1 Index 130 command. 2 Sender Prepause Timer Time from sender seizure till sending of the 1st digit where connection...
Page 403
NDA-24307 CHAPTER 5 Page 375 Issue 1 FAULT REPAIR PROCEDURES 2.2 Trunk Control Trunk circuit cards are controlled from the CPU via the MUX. Each trunk line in a specific trunk circuit card is controlled by the Port Microprocessor (PM) in a trunk circuit card. Figure 5-2 shows the control route of the trunk circuit card. Figure 5-2 Controlling Trunk Circuit Cards and Speech Path Control Signal MDF TRKPM TRK Control Signal ORT/SND LT Cable LT Cable TRK TRKPMControl Signal COT/TLT TRK TRK ORT/SND TRKPM...
Page 404
CHAPTER 5 NDA-24307 Page 376 Issue 1 FAULT REPAIR PROCEDURES 2.3 Trunk (ORT, SND, CFT) Fault Note:If a circuit card is replaced because only one line is faulty, no other lines in that circuit card can be used until the replacement is complete. When only one line is faulty Place the faulty line into make-busy state. For ORT/SND, set MB switch of each circuit to ON position. For CFT, place it into make-busy state using command MBTK. Replace the circuit card with spare. Set MB switch UP and extract the...
Page 405
NDA-24307 CHAPTER 5 Page 377 Issue 1 FAULT REPAIR PROCEDURES 2.4 Trunk (COT, TLT, DTI) Fault Note 1:If a circuit card is replaced because only one line is faulty, any other lines in that circuit card cannot be used until the replacement is complete. Note 2:If the polarities of the external line is reversed, it is detected in the form of Trunk Ineffective Hold. When OPE lamp on the trunk circuit card does not illuminateConfirm that MB switch of the trunk circuit card is in ON position (UP side). Use ATRK...
Page 406
CHAPTER 5 NDA-24307 Page 378 Issue 1 FAULT REPAIR PROCEDURES Check the faulty line on the MDF. If the C.O./Tie Line is in Loop Start system: Isolate the faulty line to C.O. side and to the system side. Connect the test telephone to the C.O. side. Note 3:Check can be made only on temporarily opened C.O./Tie Lines.Confirm that Dial Tone (DT) is heard and the call is connected to the destination party at the opposite office. Note 4:Cross connection methods are explained on the following pages.If C.O./Tie...
Page 407
NDA-24307 CHAPTER 5 Page 379 Issue 1 FAULT REPAIR PROCEDURES Note: When performing loop-back connection tests on the trunks at the user’s office, provide cross connection as follows: (1) For a COT Set up a loop-back connection between the C.O. Trunk (COT) to be tested and station line. The trunk route must be assigned for Loop Start. (2) For a TLT (for DID) Set up a loop-back connection between the Tie Line Trunk (TLT) to be tested and another TLT. If the TLT is a Direct Inward Dialing (DID) Trunk,...
Page 408
CHAPTER 5 NDA-24307 Page 380 Issue 1 FAULT REPAIR PROCEDURES If the TLT is a 2W E & M System, connect the related leads as shown below: (3) For a DTI Set up a loop-back connection between the DTI Trunk to be tested and another DTI Trunk as shown below: When the loop-back test is performed at the time of PCM LOSS, FRM LOSS, or MERM LOSS alarm lamp (red) illuminates. If the alarm lamp goes out, the DTI circuit card side is normal. When only one DTI circuit card is to be checked, make the following...
Page 409
NDA-24307 CHAPTER 5 Page 381 Issue 1 FAULT REPAIR PROCEDURES 3. ATTCON/DESKCON FAULT This section explains the fault repair procedure when a specific Attendant/Desk Console is in any of the following faulty conditions. No speech can be made. No operations can be made. 3.1 Check Point When repairing an ATTCON/DESKCON fault, consider the following items: (1) Check the cable connections on the backplane. (2) When replacing the ATI circuit card for master ATTCON/DESKCON, the system is placed under Night...
Page 410
CHAPTER 5 NDA-24307 Page 382 Issue 1 FAULT REPAIR PROCEDURES Figure 5-3 ATT Connector Cabling and Connector Leads Accommodation LT5 LT11 PIM backplane MDFATTCON/ DESKCONLT11 is used when PA-CS33 is mounted in slot 23. LT5 is used when PA-CS33 is mounted in slot 12. 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 47 34 35 36 37 38 39 40 41 42 43 44 45 46 48BN4801 BN4800 BN4820 BN4821 TAS1B TAS1A BN4810 BN4830 BN4831BN4811 TAS0B TAS0A B2 A2 B3 A3 PA-CS33 Pin Assignment Installation CableInstallation Cablefor...