NDA-24307 CHAPTER 5
Page 423
Issue 1
FAULT REPAIR PROCEDURES
8.3 Fault That Cannot Be Detected
Check the DSP flat cable (See Figure 5-13.).
If the EMA card is removed from the system while the system is in operation under
the control of the CPU 1, the system will reset and stop all call processing. See Section
1.3.2, EMA Card Replacement Procedure, Chapter 4 for detailed instructions.
Replace the EMA circuit card with a spare.
Set the MB switch of the EMA circuit card UP, and extract the circuit card...

Page 452

CHAPTER 5 NDA-24307
Page 424
Issue 1
FAULT REPAIR PROCEDURES
9. POWER SUPPLY FAULT
This section explains the fault repair procedure when any of the faults shown in Table 5-12 occur.
9.1 Check Point
When repairing a power supply fault, consider the following items:
(1) Before checking the system, check the rectifier, battery, and power cables.
(2) The PWR circuit card is equipped with the circuits to supply ringing signal and howler tone. When a fault
occurs that causes the bell of the telephone not to...

Page 453

NDA-24307 CHAPTER 5
Page 425
Issue 1
FAULT REPAIR PROCEDURES
Figure 5-15   Block Diagram of Power Supply System (IMG0)
Note:PWR1 is mounted when power supply system is a dual system configuration. 
PWR
0
PWR
1LC/TRKLC/TRKMUX0MUX1LC/TRKLC/TRK
PIM3
Note
PWR
0
PWR
1LC/TRKLC/TRKMUX0MUX1LC/TRKLC/TRK
PIM2
Note
PWR
0
PWR
1LC/TRKLC/TRKMUX0MUX1LC/TRKLC/TRK
PIM1
Note
PWR
0
PWR
1LC/TRKLC/TRKMUX0MUX1LC/TRKLC/TRK
PIM0
Note
PWR
0
PWR
1
LPM
Note
CPU0MISC
BASEUIMG1/2 (LN0/1/2/3)
LANI0ISAGT-0BISAFT-0AIOCEMA 

Page 454

CHAPTER 5 NDA-24307
Page 426
Issue 1
FAULT REPAIR PROCEDURES
Figure 5-16   Block Diagram of Power Supply System (IMG1/IMG2)
PWR
0
PWR
1LC/TRKLC/TRKMUX0MUX1LC/TRKLC/TRK
PIM3
Note
PWR
0
PWR
1LC/TRKLC/TRKMUX0MUX1LC/TRKLC/TRK
PIM2
Note
PWR
0
PWR
1LC/TRKLC/TRKMUX0MUX1LC/TRKLC/TRK
PIM1
Note
PWR
0
PWR
1LC/TRKLC/TRKMUX0MUX1LC/TRKLC/TRK
PIM0
Note
PWR
0
PWR
1MISC
LPM
Note
DLKC0PLO0/CLK0
BASEUIMG1/2 (LN0/1/2/3)
TSW03TSW02TSW01TSW00GT0
Note 1:PWR1 is mounted when power supply system is a dual system configuration....

Page 455

NDA-24307 CHAPTER 5
Page 427
Issue 1
FAULT REPAIR PROCEDURES
Figure 5-17   Block Diagram of Power Supply System (IMG3)
Note:PWR1 is mounted when power supply system is a dual system configuration. 
PWR
0
PWR
1LC/TRKLC/TRKMUX0MUX1LC/TRKLC/TRK
PIM3
Note
PWR
0
PWR
1LC/TRKLC/TRKMUX0MUX1LC/TRKLC/TRK
PIM2
Note
PWR
0
PWR
1LC/TRKLC/TRKMUX0MUX1LC/TRKLC/TRK
PIM1
Note
PWR
0
PWR
1LC/TRKLC/TRKMUX0MUX1LC/TRKLC/TRK
PIM0
Note
DUMMY
BASEUIMG3 (LN0/1/2/3) 

Page 456

CHAPTER 5 NDA-24307
Page 428
Issue 1
FAULT REPAIR PROCEDURES
(4)Figure 5-18 shows the power supply system for PIM.
Figure 5-18   Power Supply to PIM
(5)Figure 5-19 shows the power supply system for LPM.
Figure 5-19   Power Supply to LPM (LN/ISW)
DC-DC
CONV
RGU
HOW
-48V
NFB
+80V
relRGU
REL PWR0
-48V +80V   Note 
+5V, +12V, 5V
CR (for LC)
HOW (for LC)
-48V (for LC, TRK)
+80V
+80V -48V  DC-DC
CONV
RGU
HOW
-48 V
NFB
+80 V
relREL PWR1
Note:+80V is for message waiting lamp.
+5V,+12V
(To EMA, MISC, Cards,...

Page 457

NDA-24307 CHAPTER 5
Page 429
Issue 1
FAULT REPAIR PROCEDURES
(6)Figure 5-20 shows the power supply system for TSWM/ISWM.
Figure 5-20   Power Supply to TSWM/ISWM
+5V, +12V, +5V
(To MISC Cards)
-48VPWR1 PWR0
DC-DC
CONV DC-DC
CONV
-48V
+80VREL REL
-48V
+80V -48V -48V
[TSWM]
To GT, TSW, DLKC, PLO cards
[ISWM]
To IOGT, TSW, HSW, PLO cards 

Page 458

CHAPTER 5 NDA-24307
Page 430
Issue 1
FAULT REPAIR PROCEDURES
9.2 Fuse Blown Fault
Check the backplane of the PIM. Make a visual check on the backplane for pin
contacting, melting or burn, etc.
Extract all the circuit cards from the PIM,
and insert them back into their slots
individually to see if the fuse blows.Set the MB switch of the PWR supply UP.
Set the circuit breaker of the PWR supply
DOWN.
Extract all the circuit cards from their mounting
slots, except PWR supply.
Replace the fuse with spare.
Set...

Page 459

NDA-24307 CHAPTER 5
Page 431
Issue 1
FAULT REPAIR PROCEDURES
9.3 Circuit Breaker OFF Fault in PWR Supply
Check the backplane of the PIM. Make a visual check on the backplane for pin
contacting, melting or burning, etc.
Extract all the circuit cards from the PIM, 
and make a visual check of the circuit 
cards.Set MB switch of the PWR supply UP.
Set the circuit breaker of the PWR supply
DOWN.
Extract all circuit cards out of their mounting
slots.
Make a visual check of the extracted circuit
cards. 
Check...

Page 460

CHAPTER 5 NDA-24307
Page 432
Issue 1
FAULT REPAIR PROCEDURES
9.4 Fault of Alarm Lamps on PWR Supply
Note:Insert each PWR supply with its MB switch to UP side, and then set it back to DOWN side. Press RESET button of the PWR supply.
Alarm lamp goes out.FA U LT  S U P E RV I S I O N
Alarm lamp illuminates again. Set the MB switch on the PWR supply UP.
Turn circuit breaker OFF.
Set MB switch on all the circuit cards, except
PWR supply.
Extract all circuit cards from their mounting
slots.
Turn circuit...