Home > NEC > Communications System > NEC Neax 2400 Ipx System Operations And Maintenance Manual

NEC Neax 2400 Ipx System Operations And Maintenance Manual

Here you can view all the pages of manual NEC Neax 2400 Ipx System Operations And Maintenance Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 421

NDA-24307 CHAPTER 5
Page 393
Issue 1
FAULT REPAIR PROCEDURES
Place the MUX circuit card into ACT mode.
Refer to Section 12, Chapter 6.
Check to see if a station-to-station connection
can be set up to identify the circuit card
responsible for the fault.
Extract all the line/trunk circuit cards from
their mounting slots in the unit. Insert the
cards back into their slots one after another
and see if the dial tone is heard each time.Extract all the line/trunk circuit cards from their
slots.
Note:Set the MB...

Page 422

CHAPTER 5 NDA-24307
Page 394
Issue 1
FAULT REPAIR PROCEDURES
(2) For Single Configuration
Check to see if the MUX (PH-PC36)
circuit card is making poor contact.Set the MB switch of the MUX circuit card UP.
Extract the MUX circuit card from its mounting
slot and clean the contact portion.
If cleaning cannot be done, repeat insertion and
extraction of the circuit card two or three times.
Set the MB switch of the MUX circuit card UP
and insert the circuit card into its mounting slot.
Set the MB switch of...

Page 423

NDA-24307 CHAPTER 5
Page 395
Issue 1
FAULT REPAIR PROCEDURES
Extract all the line/trunk circuit cards from
their mounting slots in the unit. Insert the
cards back into their slots one after
another and see if the dial tone is heard
each time.Extract all the line/trunk circuit cards from
their slots. 
Note:Set the MB switch of the line/trunk
circuit card UP and extract.
Confirm the MUX ACT lamp on the MUX
circuit card illuminates.
Set the MB switch of an extracted Line/Trunk
circuit card UP and insert the...

Page 424

CHAPTER 5 NDA-24307
Page 396
Issue 1
FAULT REPAIR PROCEDURES
4.4 Unit Fault - ACT-Side MUX Card Is Faulty and System Has Changed Over
Faulty Situation:
The ACT side has become faulty and the system changeover has executed in the
dual configuration system.
[4-S] MUX Ready Failure / [4-T] Both MUX Failure
[23-Y] MUX Clock Failure
Check to see if the MUX (PH-PC36)
circuit card of the STBY side is making
poor contact.
If the connection is set up, set the
faulty system into STBY side.
Refer to Section 12,...

Page 425

NDA-24307 CHAPTER 5
Page 397
Issue 1
FAULT REPAIR PROCEDURES
Replace the MUX circuit card with a
spare, and check it.Replace the MUX circuit card referring to
Section 3.3.2, MUX Card Replacement
Procedure, Chapter 4.
Place the MUX circuit card into ACT mode. 
Refer to Section 12, Chapter 6.
Check to see if a station-to-station connection
can be set up and identify a circuit card
responsible for the fault.
If the connection is set up, set
the faulty system into STBY
side. Refer to Section 12,
Chapter...

Page 426

CHAPTER 5 NDA-24307
Page 398
Issue 1
FAULT REPAIR PROCEDURES
5. SPEECH PATH (TSW) SYSTEM FAULT (LN)
This paragraph explains the fault repair procedure when any of the faults shown in Ta b l e  5 - 7 has occurred in
a LN.
5.1 Check Point
When repairing a speech path fault, consider that when any of the faults shown in Ta b l e  5 - 7 have occurred
in a LN, it is possible that the TSW circuit card is at fault. Always check the alarm lamps on the TSW
circuit card. Refer to Figure 5-8.
Table 5-7  Speech Path...

Page 427

NDA-24307 CHAPTER 5
Page 399
Issue 1
FAULT REPAIR PROCEDURES
Figure 5-8   Speech Path Block Diagram (1/2)
ISWM
MUXMUXLC/TRKPIM0
IMG0 of LN0
PIM1MUXMUXLC/TRK
PIM2MUXMUXLC/TRK
PIM3MUXMUXLC/TRK
MUXMUXLC/TRKPIM0
IMG1 of LN0
PIM1MUXMUXLC/TRK
PIM2MUXMUXLC/TRK
PIM3MUXMUXLC/TRK
MUXMUXLC/TRKPIM0
IMG2 of LN0
PIM1MUXMUXLC/TRK
PIM2MUXMUXLC/TRK
PIM3MUXMUXLC/TRK
MUXMUXLC/TRKPIM0
IMG3 of LN0
PIM1MUXMUXLC/TRK
PIM2MUXMUXLC/TRK
PIM3MUXMUXLC/TRK
- Symbols -
:  Cable:  Circuit card (ACT)
:  Circuit card (ST-BY)
:  Speech...

Page 428

CHAPTER 5 NDA-24307
Page 400
Issue 1
FAULT REPAIR PROCEDURES
Figure 5-8  Speech Path Block Diagram (2/2)
ISWM
MUXMUXLC/TRKPIM0
IMG0 of LN2
PIM1MUXMUXLC/TRK
PIM2MUXMUXLC/TRK
PIM3MUXMUXLC/TRK
MUXMUXLC/TRKPIM0
IMG1 of LN2
PIM1MUXMUXLC/TRK
PIM2MUXMUXLC/TRK
PIM3MUXMUXLC/TRK
MUXMUXLC/TRKPIM0
IMG2 of LN2
PIM1MUXMUXLC/TRK
PIM2MUXMUXLC/TRK
PIM3MUXMUXLC/TRK
MUXMUXLC/TRKPIM0
IMG3 of LN2
PIM1MUXMUXLC/TRK
PIM2MUXMUXLC/TRK
PIM3MUXMUXLC/TRK
- Symbols -
:  Cable
:  Circuit card (ACT)
:  Circuit card (ST-BY)
:  Speech...

Page 429

NDA-24307 CHAPTER 5
Page 401
Issue 1
FAULT REPAIR PROCEDURES
5.2 Speech Path System Fault - Fault Related to Speech
Faulty Situation:
Fault related to speech such as noise, one-way speech, no-speed, etc. occurs.
Even if dialing started, Dial Tone (DT) does not stop.
[1-C] Both TSW Write Failure
[1-D] TSW Write Failure
(1) For Dual Configuration
Check to see if fault occurs by replacing
TSW circuit cards one by one.Replace the TSW circuit card referring to
Section 2.3.2, TSW Card Replacement...

Page 430

CHAPTER 5 NDA-24307
Page 402
Issue 1
FAULT REPAIR PROCEDURES
Check to see if a station-to-station connection
can be set up and identify a circuit card
responsible for the fault.
Perform the above check by extracting the
MUX circuit cards individually.
When the PLO (PH-CK16-A/17-A)/CLK
(PH-CLK18) circuit card is mounted for
digital interface, replace PLO/CLK circuit
card with a spare and check.Set MB switch of the PLO/CLK circuit card to
UP side.
Confirm OPE lamp on the PLO/CLK circuit
card of the mate...
Start reading NEC Neax 2400 Ipx System Operations And Maintenance Manual

Related Manuals for NEC Neax 2400 Ipx System Operations And Maintenance Manual

All NEC manuals