NDA-24307 CHAPTER 5 Page 413 Issue 1 FAULT REPAIR PROCEDURES 7. CONTROL SYSTEM FAULT This section explains the fault repair procedure for the control system listed in Table 5-9. 7.1 Check Point When repairing the control system, check the status of the following lamps: LN CPR GT TSW MUX EMA ISW CPR IOGT TSW HSW EMA Figure 5-1 and Figure 5-2 shows a block diagram of the control system. Table 5-9 Control System Fault Situation FAULTY SITUATION REFERENCE SECTION Fault occurs occasionally at the...
Page 442
CHAPTER 5 NDA-24307 Page 414 Issue 1 FAULT REPAIR PROCEDURES 7.2 Control System Fault - Fault Occurs Intermittently Faulty Situation: Fault occurs intermittently at ACT side in the dual configuration system. Fault occurs intermittently in the single configuration system. [0-C] ~ [0-K] CPU Failure [1-C] Both TSW Write Failure [1-D] TSW Write Failure [3-D], [3-E] Lock-Up Failure (Permanent/Temporary) (1) For Dual Configuration Replace ACT-side related circuit card with a spare, and check. Replace the...
Page 443
NDA-24307 CHAPTER 5 Page 415 Issue 1 FAULT REPAIR PROCEDURES (2) For Single Configuration Replace the related circuit card with a spare, and check.Replace the circuit cards individually by referring to the following sections in Chapter 4: LN Section 1.3.1, CPR Replacement Procedure Section 1.3.2, EMA Card Replacement Procedure Section 2.3.1, GT Card Replacement Procedure Section 2.3.2, TSW Card Replacement Procedure Section 3.3.2, MUX Card Replacement Procedure ISW Section 1.3.1, CPR Replacement...
Page 444
CHAPTER 5 NDA-24307 Page 416 Issue 1 FAULT REPAIR PROCEDURES 7.3 Control System Fault - STBY Side is Faulty Faulty Situation: Fault has occurred in the STBY side of dual configuration system. [0-I] STBY CPU Failure The ACT side has become faulty, and system changeover has executed. [0-C], [0-H], [0-J] Processor Failure (ACT side) Replace STBY side related circuit cards with a spare, and check.Replace the circuit cards individually by referring to the following paragraphs in Chapter 4: LN Section...
Page 445
NDA-24307 CHAPTER 5 Page 417 Issue 1 FAULT REPAIR PROCEDURES 8. ALARM INDICATION FAULT This section explains the fault repair procedure where any of the faults shown in Table 5-10 occur. 8.1 Check Point When repairing an alarm indication fault, check the alarm cable route shown in Figure 5-10 and Figure 5- 11. 8.2 Fault of Alarm Indicating Panel Table 5-10 Alarm Indication Fault Situation FAULTY SITUATION REFERENCE SECTION A fault is indicated on the TOPU, but it is not indicated on the Alarm Indicating...
Page 446
CHAPTER 5 NDA-24307 Page 418 Issue 1 FAULT REPAIR PROCEDURES Figure 5-10 Cable Routing for Alarm Indications Alarm Indicating Panel KEYDSP DSPLKEY ALMA ALMB MISC0B MISC0A EXALM ALM1 CN3CN2CN1CN0 KEY (00) (04) Alarm Lamps TOPU ISWMTOPU ISWM LPM LPM 00 0403 02 01 MMC PH-M22 To CN0 connector of LN0 To CN0 connector of LN1 To CN0 connector of LN2 To CN0 connector of LN3 MDF68PH EXMISC CA Cable A ISW (FRONT VIEW) ISW (REAR VIEW) : CHAMP connector-ended cable: Internal alarm bus cable : Connector:...
Page 447
NDA-24307 CHAPTER 5 Page 419 Issue 1 FAULT REPAIR PROCEDURES Figure 5-11 Cabling Related to Alarm Indicating Panel Table 5-11 PIN Location of External Alarm 126 2MPALM 27 328 4 EXTAA 29 530 6 BELAA 31 732 8MNAA 33MNBA 9 SUPAA 34 SUPBA 10 MJAA 35 MJBA 11 36 12 37 Alarm Indicating Panel LPM Backplane MISC0A BELAA MNAA SUPAA MJAA BELBA MNBA SUPBA MJBA RPT1(G) RPT0(-48V) Fuse -48V G MJ / MN / BELL ISW CHAMP Connector Cable MDF 68PH EXMISC CA Cable Power Receiving Terminal
Page 448
CHAPTER 5 NDA-24307 Page 420 Issue 1 FAULT REPAIR PROCEDURES Figure 5-12 Distribution/Collection of Key/Alarm Information within the System PZ-DK222 (TOP KEY) PH-PC40 PH-M22 EMA RELAY RECEIVER PZ-DK222 (TOP KEY) PH-PC40 PH-M22 EMA RELAY RECEIVER PZ-DK227 (TOP KEY) PH-PC40 PH-M22 EMA SEL RELAY RECEIVER ISEL ISW LN LN AUDIBLE AND VISUAL ALARM INDICATING PANEL KEY INFORMATION ALM INFORMATION This figure shows the flow of alarm and key information between ISW and each LN.
Page 449
NDA-24307 CHAPTER 5 Page 421 Issue 1 FAULT REPAIR PROCEDURES Figure 5-13 Alarm Bus Cable Connections Diagram (1/2) To MMC ( ) of LN3 To MMC ( ) of LN2 To MMC ( ) of LN1 ISWM HSW0/1TSW0/1IOGT0/1PLO0/1PWRSW 0/1 ISWM ALMA ALMB DSPLTOPUPZ-DK227 This figure shows the alarm bus cable connections diagram. IMG0 (LN0) MUX 0LC/TRKMUX 1PWR DPWR PIM 3 ALMA ALMB DSPLKEY KEY TOPU MUX 0LC/TRKMUX 1PWR DPWR PIM 0 ALMA ALMB EMAFHALMEMA CN0 CN0 CN0 MUX 0LC/TRKMUX 1PWR DPWR PIM 1 ALMA ALMB MUX...
Page 450
CHAPTER 5 NDA-24307 Page 422 Issue 1 FAULT REPAIR PROCEDURES Figure 5-13 Alarm Bus Cable Connections Diagram (2/2) LED3 LED2 LED1 ALM3 MUSIC ALM2 ALM1 EXALMDSP ALMKEY PALM1 MISC0B PALM0 LPM of LN0 (REAR VIEW)Slot 00 Slot 04 EMA This figure shows the alarm bus cable connections diagram. : Alarm-related connector: Circuit Card: External Cable EMA: PH-PC40 MUX: PH-PC36 IMG2 (LN0) MUX 0LC/TRKMUX 1PWR DPWR PIM 3 ALMA ALMB DSPMTOPU MUX 0LC/TRKMUX 1PWR DPWR PIM 0 ALMA ALMB TSWM1 (REAR VIEW) MUX...