NDA-24307 CHAPTER 5
Page 363
Issue 1
FAULT REPAIR PROCEDURES
1.1 Check Point
When repairing a line fault, consider the following items:
(1) Check alarm lamps on line circuit cards.
(2) When an outgoing call cannot be originated to a specific line/trunk or when an incoming call cannot be
terminated from a specific line/trunk, check Tenant Restriction Data (assigned via ATNR command) and
Route Restriction Data (assigned via ARSC/ARSCN command).
1.2 Line Control
Each line in a specific Line circuit (LC/ELC)...

Page 392

CHAPTER 5 NDA-24307
Page 364
Issue 1
FAULT REPAIR PROCEDURES
Figure 5-1   Controlling LC/ELC Circuit Cards and Speech Path
Control Signal
MDF
Ordinary Telephone/D
LCPM
LC
Control SignalLT Cable
LT CableLC/ELC
LT Cable
LT Cable
LCOrdinary Telephone/D
LCPMControl Signal
LC/ELC
Ordinary Telephone/D
LC
LC
LT Cable
LT CableLC/ELC
Ordinary Telephone/D
LCPM
LC
Control SignalLT Cable
LT CableLC/ELC
 CPR 
(LN0)LANI
CPUTo LN1 To LN2 To LN3
CPR
ISAGT
LANI
CPU
HSW
ISW IMG0/1 (LN0)
IMG2/3 (LN0)
PM
MUX
MUX
MUX
MUX...

Page 393

NDA-24307 CHAPTER 5
Page 365
Issue 1
FAULT REPAIR PROCEDURES
1.3 Line Fault - When Dial Tone (DT) Cannot Be Heard
Note:If a circuit card is replaced because only one line is
faulty, no other lines in that circuit card can be used
until the replacement is complete.
When OPE lamp on the LC circuit card
does not illuminateConfirm MB switch of the LC circuit card is in
ON position (UP).
Use ASDT command to confirm that station
data in the LC circuit card is assigned.
Replace the LC circuit card with a...

Page 394

CHAPTER 5 NDA-24307
Page 366
Issue 1
FAULT REPAIR PROCEDURES
Check the faulty line on the MDF.
Isolate the faulty line to the in-house wiring
side and to the system side.
Connect the test telephone to the system side
and check to see if dial tone can be heard.
When Dial Tone (DT) is heard Check the in-house wirings.
Replace the station telephone set with a spare.
When no DT or side tone is
heardCheck LT cables.
Replace the LC circuit card with a spare.
When DT is not heard, but side
tone can be...

Page 395

NDA-24307 CHAPTER 5
Page 367
Issue 1
FAULT REPAIR PROCEDURES
1.4 Line Fault - When Dialing Results in a Wrong Connection
Note:If a circuit card is replaced because only one line is
faulty, no other lines in that circuit card can be used
until the replacement is complete.
When a call addressed to a specific station
has terminated to another stationCheck to see if Call Forwarding-All Calls data
has been deleted.
Check the faulty line on the MDF. On the MDF, isolate the faulty line to the in-
house wiring...

Page 396

CHAPTER 5 NDA-24307
Page 368
Issue 1
FAULT REPAIR PROCEDURES
1.5 Line Fault - When Bell Does Not Ring
Note:If a circuit card is replaced because only one line is
faulty, no other lines in that circuit card can be used
until the replacement is complete.
Call the faulty station line by Station-to-
Station calling and check to see if the bell
of the telephone rings.Replace the telephone set and check to see if
its bell rings.
Check the faulty line on the MDF. Isolate  the  faulty  line  to  the  in-house...

Page 397

NDA-24307 CHAPTER 5
Page 369
Issue 1
FAULT REPAIR PROCEDURES
1.6 When Call Cannot Be Answered and Speech Cannot Be Made
Note:If a circuit card is replaced because only one line is
faulty, no other lines in that circuit card can be used
until the replacement is complete.
Check the faulty line on the MDF. Isolate  the  faulty  line  to  the  in-house  wiring
side and to the system side.
Connect the test telephone to the system side.
Call the faulty line by station-to-station
calling.
When speech can be...

Page 398

CHAPTER 5 NDA-24307
Page 370
Issue 1
FAULT REPAIR PROCEDURES
1.7 Dterm Fault
Note 1:If a circuit card is replaced because only one line
is faulty, no other lines in that circuit card can be
used until the replacement is complete.
When OPE lamp on the ELC circuit card
does not illuminateConfirm that MB switch of the ELC circuit
card is in ON position (UP).
Use ASDT command to confirm that station
data in the ELC circuit card is assigned.
Replace the ELC circuit card with a spare.
When BL lamp for each...

Page 399

NDA-24307 CHAPTER 5
Page 371
Issue 1
FAULT REPAIR PROCEDURES
Check the faulty line on the MDF. Isolate the faulty line to the in-house wiring side 
and to the system side.
Connect the test D
term to the system side.
Confirm speech by Station to Station calling.
When no speech can be made Check LT cables.
Replace ELC circuit card with a spare.
When speech can be made Check to see if the modular plug is firmly 
connected with the D
term.
Check the wiring inside the rosette.
Check the in-house wiring for...

Page 400

CHAPTER 5 NDA-24307
Page 372
Issue 1
FAULT REPAIR PROCEDURES
2. TRUNK FAULT
This paragraph explains the fault repair procedure when a fault, shown in Table 5-3, has occurred to a specific
trunk.
2.1 Check Point
When repairing a trunk fault, consider the following items:
(1) Check alarm lamps on trunk circuit cards.
(2) When an outgoing call cannot be originated to a specific trunk or when an incoming call cannot be
terminated from a specific trunk, check Tenant Restriction Data (assigned via ATNR...
Start reading NEC Neax 2400 Ipx System Operations And Maintenance Manual

Related Manuals for NEC Neax 2400 Ipx System Operations And Maintenance Manual

All NEC manuals