Page 91

NDA-24298 CHAPTER 4
Page 57
Issue 1
ATIM : Assignment of Date and Time
ATIM: Assignment of Date and Time
1. General
This command sets the clock information for the system. Clock information is executed when Y is entered in
the WRT? field and the Enter key pressed.
2. Precautions
1. The clock is assigned in military time.
2. Clock information assigned in this command is necessary for the following purposes:
(a) To indicate time for D
term and ATT (Desk Console/Hotel Console) 
(b) To specify the time for...

Page 92

CHAPTER 4 NDA-24298
Page 58
Issue 1
ATIMN : Assignment of Date and Time for NDM
ATIMN: Assignment of Date and Time for NDM
1. General
This command sets the clock information for all systems within the Fusion network. The time data assigned by
this command is adjusted according to each LN’s time difference data assigned by the ATDF command, before
updating the NDM at each LN. The completion of time data assignment for each LN is displayed on the MAT.
2. Precautions
1. Prior to this command, the time...

Page 93

NDA-24298 CHAPTER 4
Page 59
Issue 1
ATIMN : Assignment of Date and Time for NDM
3. Data Entry Instructions
YEAR
Enter the 4 digits of the year.
(For example: 1999 or 2000)
DATE TIME
YEAR MONTH DAY HOUR MINUTE SECOND
DAY
Enter the digits with a range from 1 to 31.
MINUTE
Enter the digits with a range from 1 to 60.
MONTH
Enter the digits with a range from 1 to 12.
HOUR
Enter the digits with a range from 1 to 24.
SECOND
Enter the digits with a range from 1 to 60. 

Page 94

CHAPTER 4 NDA-24298
Page 60
Issue 1
ASYD : Assignment of System Data
ASYD: Assignment of System Data
1. General
The ASYD/ASYDL command assigns the system data for the following node:
Local Node (L/N)/Network Control Node (NCN) of the Fusion network.
Stand-alone PBX
2. Precautions
1. The ASYD command contains the following indexes:
SYS 1, INDEX 0-511
SYS 2, INDEX 0-15
SYS 3, INDEX 0-31
2. The ASYDL command contains the following indexes:
SYS 1, INDEX 512-1535
SYS 2, INDEX 16-79 (Not used)
3. For...

Page 95

NDA-24298 CHAPTER 4
Page 61
Issue 1
ASYD : Assignment of System Data
3. Data Entry Instructions
 Define each bits corresponding
data referring to the SYSTEM 
DATA CONTENTS
SYSTEM
DATA
TYPE
(SYS)DATA
(DATA)
00-FF
(Hex) SYSTEM
DATA
INDEX
(INDEX)
0-511
BIT CORRE-
SPONDING
DATA
DATA
0/1BITSYSTEM DATA CONTENTS
DATA
DATA BIT
BIT
DATA
Hex 1
1b
0
b1
b2
b3
b4
b5
b6
b7
1
0
0
0
0
0
0n
n+1 FF031
1
0
0
0
0
0
0b
0
b1
b2Not used
Not used
Not used
Not used
Not used
Not used
Number of zzz b
3
b4
b5
b6
b7
xxx service 0/1...

Page 96

CHAPTER 4 NDA-24298
Page 62
Issue 1
ASYD : Assignment of System Data
4. Data Sheet
SYSTEM
DATA
TYPE 
(SYS)SYSTEM 
DATA 
INDEX 
(INDEX)
0 – 511DATA 
(DATA) 
00 – FF 
(Hex)BIT 
CORRESPONDING 
DATA
SYSTEM DATA CONTENTS
DATA 
0/1BIT
10
Number of Module Group (MG)
IPX = 01~08 (MG00~07)
(For IPX-UMG System)
01 Hex~20 Hex (MG00~MG32)
101
Number of Main Processor (fixed to “01”)
2
b00/1 = Built-in ACDP is not provided/provided. Also number 
of memory package.
3
b1-b7Not used
Configuration of Time Division...

Page 97

NDA-24298 CHAPTER 4
Page 63
Issue 1
ASYD : Assignment of System Data
14b
0
Control of ORT all Busy Status
0/1 = ROT/Queue
b
1
Recalling method when the caller has released with Emergency 
Call service
0/1 = SHF or Depressing Ground Button/Unconditional Re-
calling
Note:The operation procedure for recall is different
depending on the D
term Series III or Dterm Series E.
Dterm III user operates with SHF.
Dterm E user operates with transfer key.
b
2Releasing Method for Station to Station Calling Service
b...

Page 98

CHAPTER 4 NDA-24298
Page 64
Issue 1
ASYD : Assignment of System Data
15b
0
Access Code for C.F.-Busy Line and C.F. – Don’t Answer 
Services
0/1 = Same/Separate
Note:If “0” is assigned, assign either SID: 10 or 12 in
command ASPA.
b
1Maximum number of Multiple Call Forwarding – All Calls/
Busy Line occurrences:
b
3b2b1b3b2b1
0 00: 100: four times
0 01: 101:
0 10: twice 110:
0 11: three times 111:
Note:This data is valid when SYS-1, INDEX 69, bit 7 is
assigned as “1.” b
2
b3
b4
Miscellaneous Timer 
Counter...

Page 99

NDA-24298 CHAPTER 4
Page 65
Issue 1
ASYD : Assignment of System Data
SYS1, INDEX 6, b4 ~ b6: 
Note:Can change the key Function using the AAKP command.
1. Desk Console (Business) Key Pattern
(a) Add-on Console Key Pattern
2. Hotel Desk Console Key pattern
(a) Add-on Console Key pattern
TRKSL SVC SC SCRN
DND
OverrideHWS BV
WUS DDS RCS MWS Check In AUD
WUR DDR RCR MWR Check out STS
LDN
EMGTIE
BVBUSY
TRKSLATND NANS
SCRecall
SVCTF
(FRL)(FX)
(ICPT)PA G E
StartREC
Mute
Pattern 4 (b4=0, b5=0, b6=1)
LDN
EMGTIE...

Page 100

CHAPTER 4 NDA-24298
Page 66
Issue 1
ASYD : Assignment of System Data
(b) Add-on Console Key pattern
3. Desk Console (Business) Key pattern for Hotel application system
(a) Add-on Console Key pattern
(b) Add-on Console Key pattern
TRKSL SC FRL CP
DND
OverrideCAS BV
WUS DDS RCS MWS Check In AUD
WUR DDR RCR MWR Check out STS
CAS CCSA WATS
CAS CCSA WATS
LDN
EMGTIE
HPBusy
DNDADM NANS
OTRecall
ICPTTF
WAT SFX
CCSAPA G E
StartREC
Mute
Pattern 4 (b4=0, b5=0, b6=1)
GST
LDN
EMGTIE
BVBusy
TRKSLATND NANS
SCRecall...
Start reading NEC Neax 2400 Ipx Office Data Specification

Related Manuals for NEC Neax 2400 Ipx Office Data Specification

All NEC manuals