NDA-24298 CHAPTER 4
Page 77
Issue 1
ASYD : Assignment of System Data
SYSTEM
DATA
TYPE 
(SYS)SYSTEM 
DATA 
INDEX 
(INDEX)
0 – 511DATA 
(DATA) 
00 – FF 
(Hex)BIT 
CORRESPONDING 
DATA
SYSTEM DATA CONTENTS
DATA 
0/1BIT
135b
0
Not used b
1
b2
b3
b4
b5
b6
b7
36 00Not used
37 00
Not used
38b
0Stand-Alone Fault Printer Accommodation Designation “1” is to 
be assigned to each bit corresponding to the Port Number of the 
IOC circuit card.
b
0 = Port 0 b1 = Port 1
b
2 = Port 2  b3 = Port 3
b
4 = Port 4 b5 = Port 5...

Page 112

CHAPTER 4 NDA-24298
Page 78
Issue 1
ASYD : Assignment of System Data
140 00b
0~b4Not used
b5
SMDR Buffer Overflow Alarm
0/1 = Fault @ 80%, Clear @ 50%/Use Indexes 249 and 250.
b6Not used
b7Not used
41b
0~b6
OG Queuing Override – DDD Seizing Timer
Timer Counter (TC) is to be assigned a value from 01 Hex to 7F 
Hex.
Timer Value Setting is (TC) 
× 30 sec.
Note:When this data (TC) is 00 Hex, default data of 3 minutes
is set.
0b
7Not used
42
b0 ~ b1Not used
b
2
System Message “5-Q”, ACD MIS Lock up, is to be...

Page 113

NDA-24298 CHAPTER 4
Page 79
Issue 1
ASYD : Assignment of System Data
143b
0
For Remote Access to System, is Forced Account (F/A) Code 
Dialing required upon receiving RBT?
0/1 = Required/Not Required
0b
1Not used
b
2
Send SST after ACC Code dialing for Authorization Code or F/A 
code is dialed using LCR Access
0/1 = Out/In Service
0b
3Not used
b
4
ATT Re-enters Loop on Serial Call
0/1 = Restriction/Allowed
b
5
Send DT to the distant Office upon receiving Terminated Office 
Code (Tandem)
0/1 = Not...

Page 114

CHAPTER 4 NDA-24298
Page 80
Issue 1
ASYD : Assignment of System Data
145
Abnormal Call, Short Duration Timer for Automatic Circuit 
Assurance service (when INDEX = 44, b
0 = 1)
Timer counter (TC) is to be assigned a value from 02 Hex to FF 
Hex. (2 - 255 sec.)
Timer Value = TC × 1 sec.
Note:When TC = 00 Hex, this timer is not set.
46
Abnormal Call, Long Duration Timer for Automatic Circuit 
Assurance service
(when INDEX = 44, b
0 = 1)
TC is to be assigned a value from 01 Hex to FF Hex. (1 - 255 
min.)...

Page 115

NDA-24298 CHAPTER 4
Page 81
Issue 1
ASYD : Assignment of System Data
Note:
When assigning data for INDEXes 56 and 57, be sure to assign data in such a way that the data value of
INDEX 56 is larger than INDEX 57 (Value of INDEX 56>Value of INDEX57).
148
Do not assign these INDEXes.
(INDEXes 48 ~ 55 are used for the Grade 1 Password Code.) 49
50
51
52
53
54
55
56 FFb
0Set Line Load Control (Automatic) Execution Occupancy Rate.
Set execution of line load control (automatic) by the usage rate 
(occupancy)...

Page 116

CHAPTER 4 NDA-24298
Page 82
Issue 1
ASYD : Assignment of System Data
SYSTEM
DATA
TYPE 
(SYS)SYSTEM 
DATA 
INDEX 
(INDEX)
0 – 511DATA 
(DATA)
00 – FF 
(Hex)BIT 
CORRESPONDING 
DATA
SYSTEM DATA CONTENTS
DATA 
0/1BIT
158
b0
Configuration of CPU (for IPX)
0/1 = Single/Dual
For IPX, assign “0.”
0
b1Not used
1
b2Trunk Ineffective Hold Detect Processing Program Start 
0/1 = Not Required/Required (Always assign “1.”)
1
b3Send Forced Off-Hook Supervisory Command
0/1 = Not Required/Required (Always assign “1.”)
0...

Page 117

NDA-24298 CHAPTER 4
Page 83
Issue 1
ASYD : Assignment of System Data
1600b
0
Not used 0b1
0b2
b3
UCD Queuing
0/1 = Required (RBT)/Not Required (BT)
(Most = 0 when the MCI is in service.)
b
4
Nailed Down Connection (Fixed Connection) service
0/1 = Out/In service
b
5
Send Warning Tone to interrupted parties when Attendant 
Interruption service is operated.
0/1 = Required/Not Required
0b
6Not used
0b
7
610b
0
Not used 0b
1
0b2
0b3
0b4
b5
Call Waiting Display – UCD/ACD Service
0/1 = Out/In Service
0b
6Not...

Page 118

CHAPTER 4 NDA-24298
Page 84
Issue 1
ASYD : Assignment of System Data
1620b
0
Not used 0b
1
0b2
0b3
0b4
0b5
b6AC T/ ST  – BY Change over at Routine Diagnosis
00=Every time
0 1 = Once a week (On Sunday)
1 0 = Once a month (On the 1st Sunday of the month)
11=–
Note:Assign the Routine Diagnosis Program start time in
SYS-1, INDEXes 87 and 88. b
7
63 00b
0
Blind Transfer for stations in service
0/1 = No/Yes
b1
Not usedb2
b3
b4Not used
b5
Exclusive Hold for stations
0/1 = Yes/No
b6Not usedb7
SYSTEM
DATA
TYPE...

Page 119

NDA-24298 CHAPTER 4
Page 85
Issue 1
ASYD : Assignment of System Data
164b
0
µ law/A law for TDSW
0 = µ law (Japan, North America, Canada, and Hong Kong)
1 = A law (Europe, other nations)
b
1Display of Call Waiting Lamp (on Attendant Console) service
0 0 = When PA lamp illuminates
0 1 = When busy lamp field is not displayed
10=Always
11=– b
2
b3Howler Tone sending service
00=Out of Service
0 1 = Send one time only
1 0 = Repeat every 30 sec.
11=–
Note:The Sending Timer may be changed to a value other
than...

Page 120

CHAPTER 4 NDA-24298
Page 86
Issue 1
ASYD : Assignment of System Data
167 000b
0
Not used 0b
1
0b2
0b3
0b4
0b5
0b6
SMDR Control Circuit Card Designation
0/1 = MRC/SMDC (Always assign “0.”)
0b
7
SMDR Sending Designation
0/1 = AP/SMDC (Always assign “0.”)
68b
0
Operating method for busy station service (Call back, Executive 
Right of Way, etc.)
0/1 = SHF + Access Code/Last Digit + Access Code
b
1
Operating method for Individual Trunk Access (ATT) service
0 = Route No. + Trunk No.
1 = C.O. Code (as assigned...