NEC Neax 2400 Ipx Office Data Specification
Here you can view all the pages of manual NEC Neax 2400 Ipx Office Data Specification. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 121
NDA-24298 CHAPTER 4 Page 87 Issue 1 ASYD : Assignment of System Data 169b 0 Return transferred call to transferring party after Recall Timer expires (Call Transfer – All Calls or Blind Transfer to Station service) 0/1 = Recall/No Recall, or execution of Call Forwarding – Don’t Answer (when C.F. – Don’t Answer is set at the transfer destination station) b 1 Send short tone when a call forwarded via C.F. – All Calls service is answered. 0/1 = Not Required/Required b 2 Send short tone when a recalled...
Page 122
CHAPTER 4 NDA-24298 Page 88 Issue 1 ASYD : Assignment of System Data 170b 0 Called Number Display when forwarding to Attendant Console 0/1 = Out/In Service b 1 Flashing display of Line Lockout on Attendant Console BLF 0/1 = In Service/Out b 2Route No. Display on Attendant Console b 3 b4 One digit dialing instead of SHF (DP TEL only) 0/1 = Not Required/Required b 5 Priority order for answering via ANSWER key 0 = Priority according to Type of Call 1 = Priority according to the order call termination b 6...
Page 123
NDA-24298 CHAPTER 4 Page 89 Issue 1 ASYD : Assignment of System Data 1720b 0 Not used 0b 1 0b2 0b3 0b4 0b5 b6 Distinctive Ringing (DR) only for Direct-In Termination (DIT), Direct-In Dialing (DID) calls Note:Assign “0” or “1” according to Table 4-2. 0b 7Not used 73b 0Type of Paging Service b 1b0b1b0 00=No Answer Note 10=Delay 0 1 = No Delay 1 1 = Delay with Paging Transfer Note:Ringback Tone when CDN6 = 8. b 1 b2 Radio Page Number 0/1 = 2 digits/3 digits b 3 Paging Cancel Code 0/1 = Individual Paging...
Page 124
CHAPTER 4 NDA-24298 Page 90 Issue 1 ASYD : Assignment of System Data b601 Parameter DR assigned via command “ARTD”0101 Direct-In Termination (DIT) Ringer Pattern 1 Ringer Pattern 0 Ringer Pattern 1 Ringer Pattern 0 Via Attendant Console Ringer Pattern 1 Ringer Pattern 0 Ringer Pattern 1 Ringer Pattern 1 Via other station Ringer Pattern 1 Ringer Pattern 0 Ringer Pattern 1 Ringer Pattern 1 Interoffice call Ringer Pattern 1 Ringer Pattern 1 Ringer Pattern 1 Ringer Pattern 1 SYSTEM DATA TYPE (SYS)SYSTEM...
Page 125
NDA-24298 CHAPTER 4 Page 91 Issue 1 ASYD : Assignment of System Data 175b 0 Route Restriction Class Data (ARSC command) 0/1 = Common/Separate Table Development: Common or Separate Day/Night Data Ta- bles. Note:When data tables are designated as “Common,” the Day mode designation must be used in the respective commands. b 1 Service Feature Restriction class Data (ASFC command) 0/1 = Common/Separate b 2 Tenant Restriction Data (ATNR command) 0/1 = Common/Separate b 3 Toll Code Restriction Data...
Page 126
CHAPTER 4 NDA-24298 Page 92 Issue 1 ASYD : Assignment of System Data 1760b 0Not used 0b 1 Same Special Access Code Data (ASPS command) 0/1 = Common/SeparateTable Development: Common or Separate Day/Night Data Ta- bles. Note:When data tables are designated as “Common”, the Day mode designation must be used in the respective commands. b 2 Call Forwarding Service by Calling Number Data (AFCP command) 0/1 = Common/Separate 0b 3 Not used 0b 4 0b5 0b6 0b7 77b 0 Day/Night mode change via the...
Page 127
NDA-24298 CHAPTER 4 Page 93 Issue 1 ASYD : Assignment of System Data 1781b 0 Display Station numbers on the Attendant Console and stations 0/1 = Out/In Service (Always assign “1.) 1b 1 Kind of Service Class indication (Dterm) 0/1 = Out/In Service (Always assign “1.) 0b 2Not used 0b 3 Station Number with Name Display 0/1 = Out/In Service 0b 4Not used b 5 Name Display Service 0/1 = Out/In Service 0b 6Not used 0b 7 790b 0Not used 0b 1 b2 Split Call Forwarding Service 0/1 = Out/In Service 0b 3Not used 0b 4...
Page 128
CHAPTER 4 NDA-24298 Page 94 Issue 1 ASYD : Assignment of System Data 1800b 0Not used b 1 Call Block Service - Key used for canceling the Rejection Number 0/1 = # key/* key 0b 2 Clear last input from LCD when in OAI Mode 0/1 = Yes/No 0b 3 Display static ACD messages (Break, Ready, etc.) on the second line of the LCD. 0/1 = No/Yes 0b 4 Not used 0b5 0b6 0b7 81 00Not used 82b 0Station Number Display Pattern on the Attendant Console b 3 – b0 = Station Number Display Pattern b 7 – b4 = Station Number Display...
Page 129
NDA-24298 CHAPTER 4 Page 95 Issue 1 ASYD : Assignment of System Data 184 FF1b 0 Data Memory Segment Location Designation 1b 1 1b2 1b3 1b4 1b5 1b6 1b7 85 FF1b 0 1b1 1b2 1b3 1b4 1b5 1b6 1b7 SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 – 511DATA (DATA) 00 – FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT
Page 130
CHAPTER 4 NDA-24298 Page 96 Issue 1 ASYD : Assignment of System Data 186b 0 System Message “7-0” is registered when no errors are detected by the Routine Diagnosis Program (Refer to INDEX 89 and 90) 0/1 = Not Registered/Registered b 1 System Message “7-P” is registered when an error is detected by the Routine Diagnosis Program (Refer to INDEX 89 and 90) 0/1 = Not Register/Register b 2Fault Recovery Pattern upon TRK Ineffective Hold Detection 0 0 = Release all calls other than basic calls (two-way...