Home > NEC > Communications System > NEC Neax 2400 Ipx Office Data Specification

NEC Neax 2400 Ipx Office Data Specification

Here you can view all the pages of manual NEC Neax 2400 Ipx Office Data Specification. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 151

NDA-24298 CHAPTER 4
Page 117
Issue 1
ASYD : Assignment of System Data
1146
b0Howler Tone Timer:
Miscellaneous Timer Counter (MTC) is to 
be assigned a value from 0 Hex to F Hex 
(0-15).This timer assigns 
the duration 
between tones when 
Howler Tone is 
being sent to a 
station.
Timer Value Setting 
is MTC 
× TC. 
The Interval Pattern 
is assigned in 
INDEX 64, b
3 and 
b
4
Note:When this 
data is 00 
Hex, default 
data is 
automatically 
set to 30 sec.
b1
b2
b3
b4Timer Class (TC) is to be assigned one...

Page 152

CHAPTER 4 NDA-24298
Page 118
Issue 1
ASYD : Assignment of System Data
1149
b0Camp-On Recall Timer for CAS-Satellite 
Station:
Miscellaneous Timer Counter (MTC) is to 
be assigned a value from 0 Hex to F Hex 
(0-15).The duration for 
which a call will 
remain Camped-On 
to a station at the 
Satellite PBX before 
being recalled to the 
attendant.
Timer Value Setting 
is MTC 
× TC sec.
Note:When this 
data is 00 
Hex, default 
data is 
automatically 
set to 30-32 
sec.
b1
b2
b3
b4Timer Class (TC) is to be...

Page 153

NDA-24298 CHAPTER 4
Page 119
Issue 1
ASYD : Assignment of System Data
1151
b0SHF length for a CAS Main Station:
Miscellaneous Timer Counter (MTC) is to 
be assigned a value from 00 Hex to 1F Hex 
(0-31).The length of an 
SHF signal being 
sent from the Main 
to a Satellite PBX.
Timer Value Setting 
is MTC 
× 32 msec. 
(MTC+1) 
× 32 
msec.
Note:When this 
data is 00 
Hex, default 
data is 
automatically 
set from 448 
msec.-480 
msec.
b1
b2
b3
b4
b5
Not usedb6
b7
152
b0Interval for Call Waiting Indication...

Page 154

CHAPTER 4 NDA-24298
Page 120
Issue 1
ASYD : Assignment of System Data
1153
b0Data Communication RS-232C RS-CS 
Signal Control service:
This timer is to be assigned a value from 0 
Hex to F Hex (0-15)
0 Hex = 60 msec.
1-7 Hex =–
8 Hex = 0 msec.
9 Hex = 30 msec.
A Hex = 60 msec.
B Hex = 120 msec.
C Hex = 240 msec.
D Hex = 360 msec.
E Hex = 720 msec.
F Hex = 1080 msec.RS-232C Guard 
Time after RS-ON 
until CS-ON during 
data 
communications.
Note:When this 
data is 00 
Hex, default 
data is 
automatically...

Page 155

NDA-24298 CHAPTER 4
Page 121
Issue 1
ASYD : Assignment of System Data
1156
b0Trunk Soft Hold Timer A:
Miscellaneous Timer Counter (MTC) is to 
be assigned a value from 0 Hex to F Hex
(0-15).Timer Value Setting 
is MTC 
× TC sec.
Note:When this 
data is 00 
Hex, default 
data is 
automatically 
set to 30 sec.
b1
b2
b3
b4Timer Class (TC) is to be assigned one of 
the following values:
b6b5b4b6b5b4
0 00=–100=–
0 01=–101=–
0 10=–110=–
0 11=2 sec.111=–
b5
b6
0b7Not used
157
b0Trunk Soft Hold Timer B:...

Page 156

CHAPTER 4 NDA-24298
Page 122
Issue 1
ASYD : Assignment of System Data
1158
b0Attendant Console Busy Verification 
Warning Tone Timer:
Miscellaneous Timer Counter (MTC) is to 
be assigned a value from 0 Hex to F Hex 
(0-15).
The interval between 
BV tones.
Timer Value Setting 
is MTC 
× TC sec.
Note:When this 
data is 00 
Hex, default 
data is 
automatically 
set to 14 sec.
b1
b2
b3
b4Timer Class (TC) is to be assigned one of 
the following values:
b6b5b4b6b5b4
0 00=–100=–
0 01=–101=–
0 10=–110=–
0 11=2...

Page 157

NDA-24298 CHAPTER 4
Page 123
Issue 1
ASYD : Assignment of System Data
11601b
0Hotel Feature required (Fixed Data)
(for Hotel system) 1b
1Hotel Service kind (Fixed Data)
b
2
Length of Room Status Memory
0/1 = 8 byte/24 byte
0b
3Pattern of Key Arrangement on Attendant 
Console
(Refer to Table 4-1.) (Usually, 00) 0b
4
b5Guest Name Service 0/1 = Out/In Service
b
6
Numbering Plan Data Table of Guest 
Station and Admin. Stations
0/1 = Separate/Common
Note 1:If data is assigned as 1, only use
commands AANP and...

Page 158

CHAPTER 4 NDA-24298
Page 124
Issue 1
ASYD : Assignment of System Data
1161b
0
Don’t Disturb Override key on the 
Attendant Console
0/1 = Out/In Service
(for Hotel system) b
1
Message Waiting Service
0/1 = Out/In Service
b
2
Language Service
0/1 = Out/In Service
b
3
Split Hold Service
0/1 = Out/In Service
0b
4Not used
b
5
DSS (Direct Station Select) Key on the 
Attendant Console
0/1 = Ineffective/Effective
b
6
Timing Start using “#” Code
0/1 = Ineffective/Effective
Note 1:This data is available in both...

Page 159

NDA-24298 CHAPTER 4
Page 125
Issue 1
ASYD : Assignment of System Data
Table 4-1 Key Arrangements for Hotel Add-On Console
DATA
KEY ARRANGEMENT REMARKS
b
4b3
00WUS: Wake-Up Set
WUR: Wake-Up Reset
DDS: Do Not Disturb Set
DDR: Do Not Disturb Reset
MWS: Message Waiting Set
MWR: Message Waiting Reset
RCS: Room Cut Off Set
RCR: Room Cut Off Reset
AUD: Audit Report
STS: Status Check
C/I: Check In
C/O: Check Out
SCS: Boss-Secretary Set
SCR: Boss-Secretary Reset
COC: Manual Switching of C.O. Incom-
ing Call 01...

Page 160

CHAPTER 4 NDA-24298
Page 126
Issue 1
ASYD : Assignment of System Data
SYSTEM
DATA
TYPE
(SYS)SYSTEM
DATA
INDEX
(INDEX)
0 - 511DATA
(DATA)
00 - FF
(Hex.)BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATAea
0/1BIT
11620
b0
Assign 00 for business 
systems. 0
b1
0b2
0b3
0b4
0b5
0b6
0b7
1630
b0
Assign 00 for business 
systems. 0
b1
0b2
0b3
0b4
0b5
0b6
0b7
164 000
b0
0b1
0b2
0b3
0b4
0b5
0b6
0b7
165 000
b0
0b1
0b2
0b3
0b4
0b5
0b6
0b7 
Start reading NEC Neax 2400 Ipx Office Data Specification

Related Manuals for NEC Neax 2400 Ipx Office Data Specification

All NEC manuals