NEC Neax 2400 Ipx Office Data Specification
Here you can view all the pages of manual NEC Neax 2400 Ipx Office Data Specification. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 151
NDA-24298 CHAPTER 4 Page 117 Issue 1 ASYD : Assignment of System Data 1146 b0Howler Tone Timer: Miscellaneous Timer Counter (MTC) is to be assigned a value from 0 Hex to F Hex (0-15).This timer assigns the duration between tones when Howler Tone is being sent to a station. Timer Value Setting is MTC × TC. The Interval Pattern is assigned in INDEX 64, b 3 and b 4 Note:When this data is 00 Hex, default data is automatically set to 30 sec. b1 b2 b3 b4Timer Class (TC) is to be assigned one...
Page 152
CHAPTER 4 NDA-24298 Page 118 Issue 1 ASYD : Assignment of System Data 1149 b0Camp-On Recall Timer for CAS-Satellite Station: Miscellaneous Timer Counter (MTC) is to be assigned a value from 0 Hex to F Hex (0-15).The duration for which a call will remain Camped-On to a station at the Satellite PBX before being recalled to the attendant. Timer Value Setting is MTC × TC sec. Note:When this data is 00 Hex, default data is automatically set to 30-32 sec. b1 b2 b3 b4Timer Class (TC) is to be...
Page 153
NDA-24298 CHAPTER 4 Page 119 Issue 1 ASYD : Assignment of System Data 1151 b0SHF length for a CAS Main Station: Miscellaneous Timer Counter (MTC) is to be assigned a value from 00 Hex to 1F Hex (0-31).The length of an SHF signal being sent from the Main to a Satellite PBX. Timer Value Setting is MTC × 32 msec. (MTC+1) × 32 msec. Note:When this data is 00 Hex, default data is automatically set from 448 msec.-480 msec. b1 b2 b3 b4 b5 Not usedb6 b7 152 b0Interval for Call Waiting Indication...
Page 154
CHAPTER 4 NDA-24298 Page 120 Issue 1 ASYD : Assignment of System Data 1153 b0Data Communication RS-232C RS-CS Signal Control service: This timer is to be assigned a value from 0 Hex to F Hex (0-15) 0 Hex = 60 msec. 1-7 Hex =– 8 Hex = 0 msec. 9 Hex = 30 msec. A Hex = 60 msec. B Hex = 120 msec. C Hex = 240 msec. D Hex = 360 msec. E Hex = 720 msec. F Hex = 1080 msec.RS-232C Guard Time after RS-ON until CS-ON during data communications. Note:When this data is 00 Hex, default data is automatically...
Page 155
NDA-24298 CHAPTER 4 Page 121 Issue 1 ASYD : Assignment of System Data 1156 b0Trunk Soft Hold Timer A: Miscellaneous Timer Counter (MTC) is to be assigned a value from 0 Hex to F Hex (0-15).Timer Value Setting is MTC × TC sec. Note:When this data is 00 Hex, default data is automatically set to 30 sec. b1 b2 b3 b4Timer Class (TC) is to be assigned one of the following values: b6b5b4b6b5b4 0 00=–100=– 0 01=–101=– 0 10=–110=– 0 11=2 sec.111=– b5 b6 0b7Not used 157 b0Trunk Soft Hold Timer B:...
Page 156
CHAPTER 4 NDA-24298 Page 122 Issue 1 ASYD : Assignment of System Data 1158 b0Attendant Console Busy Verification Warning Tone Timer: Miscellaneous Timer Counter (MTC) is to be assigned a value from 0 Hex to F Hex (0-15). The interval between BV tones. Timer Value Setting is MTC × TC sec. Note:When this data is 00 Hex, default data is automatically set to 14 sec. b1 b2 b3 b4Timer Class (TC) is to be assigned one of the following values: b6b5b4b6b5b4 0 00=–100=– 0 01=–101=– 0 10=–110=– 0 11=2...
Page 157
NDA-24298 CHAPTER 4 Page 123 Issue 1 ASYD : Assignment of System Data 11601b 0Hotel Feature required (Fixed Data) (for Hotel system) 1b 1Hotel Service kind (Fixed Data) b 2 Length of Room Status Memory 0/1 = 8 byte/24 byte 0b 3Pattern of Key Arrangement on Attendant Console (Refer to Table 4-1.) (Usually, 00) 0b 4 b5Guest Name Service 0/1 = Out/In Service b 6 Numbering Plan Data Table of Guest Station and Admin. Stations 0/1 = Separate/Common Note 1:If data is assigned as 1, only use commands AANP and...
Page 158
CHAPTER 4 NDA-24298 Page 124 Issue 1 ASYD : Assignment of System Data 1161b 0 Don’t Disturb Override key on the Attendant Console 0/1 = Out/In Service (for Hotel system) b 1 Message Waiting Service 0/1 = Out/In Service b 2 Language Service 0/1 = Out/In Service b 3 Split Hold Service 0/1 = Out/In Service 0b 4Not used b 5 DSS (Direct Station Select) Key on the Attendant Console 0/1 = Ineffective/Effective b 6 Timing Start using “#” Code 0/1 = Ineffective/Effective Note 1:This data is available in both...
Page 159
NDA-24298 CHAPTER 4 Page 125 Issue 1 ASYD : Assignment of System Data Table 4-1 Key Arrangements for Hotel Add-On Console DATA KEY ARRANGEMENT REMARKS b 4b3 00WUS: Wake-Up Set WUR: Wake-Up Reset DDS: Do Not Disturb Set DDR: Do Not Disturb Reset MWS: Message Waiting Set MWR: Message Waiting Reset RCS: Room Cut Off Set RCR: Room Cut Off Reset AUD: Audit Report STS: Status Check C/I: Check In C/O: Check Out SCS: Boss-Secretary Set SCR: Boss-Secretary Reset COC: Manual Switching of C.O. Incom- ing Call 01...
Page 160
CHAPTER 4 NDA-24298 Page 126 Issue 1 ASYD : Assignment of System Data SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 - 511DATA (DATA) 00 - FF (Hex.)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATAea 0/1BIT 11620 b0 Assign 00 for business systems. 0 b1 0b2 0b3 0b4 0b5 0b6 0b7 1630 b0 Assign 00 for business systems. 0 b1 0b2 0b3 0b4 0b5 0b6 0b7 164 000 b0 0b1 0b2 0b3 0b4 0b5 0b6 0b7 165 000 b0 0b1 0b2 0b3 0b4 0b5 0b6 0b7