Page 131
NDA-24298 CHAPTER 4 Page 97 Issue 1 ASYD : Assignment of System Data 187 Hour data is assigned using a decimal number (Military Time) Example:2:00 a.m. – This data is entered as 02. Example:2:30 p.m. – This data is entered as 14.Routine Diagnosis Program Start Time Note:When both Index 87 and Index 88 are assigned data “FF” Hex, the Routine Diagnosis Program is not executed. 88 Minute data is assigned using a deci- mal number (Military Time) Example:2:00 a.m. – This data is entered as 00....
Page 132
CHAPTER 4 NDA-24298 Page 98 Issue 1 ASYD : Assignment of System Data 190b 0Not used b 1 Backup Call Forwarding and Individual Speed Data to HDD (See Index 304) 0/1 = No/Yes b 2Not used b 3 Residual link detect 0/1 = No/Yes b 4 LP ACT/STBY Changeover (for IPX-UMG system) 0/1 = No/Yes b 5 CMP ACT/STBY Changeover (for IPX-UMG system) 0/1 = No/Yes b 6Not used b 7 910b 0Not used 0b 1 b2Grades of System Message that can be Registered: 0 0 = Register All System Message Data 0 1 = Register System Message Data...
Page 133
NDA-24298 CHAPTER 4 Page 99 Issue 1 ASYD : Assignment of System Data 192b 0System Data-2 (ASYD command) Separate or Common Tenant Data table de- velopment for the re- spective commands 0/1 = Separate/Com- mon Note:When data “1” is assigned, data must be assigned for Tenant 1 (TN = 1) in the respective commands. b 1Special Access Code Data (ASPA, AASP, AGSP command) b 2Numbering Plan Data (ANPD, AANP, AGNP command) b 3Station Data (ASDT, AAST, AGST, ALDN, ASAT commands) b 4Route Restriction...
Page 134
CHAPTER 4 NDA-24298 Page 100 Issue 1 ASYD : Assignment of System Data 194b 0Tenant Restriction Class Data (ATNR command) Separate or Common Tenant Data table de- velopment for the re- spective commands 0/1 = Separate/Com- mon Note:When data “1” is assigned, data must be assigned for Tenant 1 (TN = 1) in the respective commands. b 1EPN Facility Restriction Data (AEFR command) b 2Primary Call Restriction Data (APCR command) b 3Authorization Code Data (AATC command) b 4Special Access Code for...
Page 135
NDA-24298 CHAPTER 4 Page 101 Issue 1 ASYD : Assignment of System Data 196 End User’s Office Name (INDEX 96-115) Note 1:The End User’s Office Name must be less than 20 characters. Note 2:A blank is assigned as data “20 Hex”. Example:If the End User’s Office Name is “NEC CORP. (TOKYO),” assignment is as follows: 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 – 511DATA (DATA) 00 – FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA...
Page 136
CHAPTER 4 NDA-24298 Page 102 Issue 1 ASYD : Assignment of System Data Note 1: When setting the data that designates Print/Message Center and MAT, be sure the data is not duplicated in the Port number data to be assigned by SYS-1, INDEX 288, 290, 292, and 294. Also, when setting the data that designates SMDR, it is necessary to assign the corresponding data to SYS-1, INDEX 288, 290, 292, and 294. Note 2:Bits 0 ~ 6 are assigned in the AIOC command. Only bit 7 may be changed using this index. Note 3:When...
Page 137
NDA-24298 CHAPTER 4 Page 103 Issue 1 ASYD : Assignment of System Data Note 1:When setting the data that designates Print/Message Center and MAT, be sure the data is not duplicated in the Port number data assigned by SYS-1, INDEX 288, 290, 292, and 294. When setting the data that designate SMDR, it is necessary to assign the corresponding data to SYS-1, INDEX 288, 290, 292, and 294. Note 2:Bits 0 ~ 6 are assigned in the AIOC Command. Only bit 7 may be changed using this index. Note 3:When activating the...
Page 138
CHAPTER 4 NDA-24298 Page 104 Issue 1 ASYD : Assignment of System Data Note 1: When setting the data that designates Print/Message Center and MAT, be sure the data is not duplicated in the Port number data assigned by SYS-1, INDEX 288, 290, 292, and 294. When setting the data that designate SMDR, it is necessary to assign the corresponding data to SYS-1, INDEX 288, 290, 292, and 294. Note 2:Bits 0 ~ 6 are assigned in the AIOC Command. Only bit 7 may be changed using this index. Note 3: When activating the...
Page 139
NDA-24298 CHAPTER 4 Page 105 Issue 1 ASYD : Assignment of System Data Note:When activating the Password function, assign “b 7 = 1” ONLY after a Password Code has been assigned via com- mand APSW. Note:When activating the Password function, assign “b 7 = 1” ONLY after a Password Code has been assigned via command APSW. SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 - 511DATA (DATA) 00 - FF HEXBIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT 11220 b0 Not used Data for Port 6 of the IOC...
Page 140
CHAPTER 4 NDA-24298 Page 106 Issue 1 ASYD : Assignment of System Data SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 - 511DATA (DATA) 00 - FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT 1124 00 Not used 125 b0MFC Sender PAD Control Note:Source Signal is -8 dBm b3b2b1b0 0 000 =-0 dB 0 001 =-2 dB 0 010 =-4 dB 0 011 =-6 dB 0 100 =-8 dB 0 101 =-10 dB 0 1 1 0 = -11.5 dB 0 111 =-14 dB 1 000- 1111 =Not used b1 b2 b3 b4MFC Signaling System b3b2b1b0 0 000=NEC Standard (Complies with the CCITT...