NDA-24298 CHAPTER 4
Page 97
Issue 1
ASYD : Assignment of System Data
187
Hour data is assigned using a decimal 
number (Military Time)
Example:2:00 a.m. – 
This data is 
entered as 02.
Example:2:30 p.m. – 
This data is 
entered as 14.Routine Diagnosis 
Program Start Time
Note:When both
Index 87 and
Index 88 are
assigned data
“FF” Hex,
the Routine
Diagnosis
Program is
not executed. 88
Minute data is assigned using a deci-
mal number (Military Time)
Example:2:00 a.m. – 
This data is 
entered as 00....

Page 132

CHAPTER 4 NDA-24298
Page 98
Issue 1
ASYD : Assignment of System Data
190b
0Not used
b
1
Backup Call Forwarding and Individual Speed Data to HDD 
(See Index 304)
0/1 = No/Yes
b
2Not used
b
3
Residual link detect
0/1 = No/Yes
b
4
LP ACT/STBY Changeover (for IPX-UMG system)
0/1 = No/Yes
b
5
CMP ACT/STBY Changeover (for IPX-UMG system)
0/1 = No/Yes
b
6Not used
b
7
910b
0Not used
0b
1
b2Grades of System Message that can be Registered:
0 0 = Register All System Message Data
0 1 = Register System Message Data...

Page 133

NDA-24298 CHAPTER 4
Page 99
Issue 1
ASYD : Assignment of System Data
192b
0System Data-2 (ASYD command) Separate or Common 
Tenant Data table de-
velopment for the re-
spective commands
0/1 = Separate/Com-
mon
Note:When data 
“1” is 
assigned, 
data must be 
assigned for 
Tenant 1 
(TN = 1) in 
the respective 
commands. b
1Special Access Code Data (ASPA, 
AASP, AGSP command)
b
2Numbering Plan Data (ANPD, AANP, 
AGNP command)
b
3Station Data (ASDT, AAST, AGST, 
ALDN, ASAT commands)
b
4Route Restriction...

Page 134

CHAPTER 4 NDA-24298
Page 100
Issue 1
ASYD : Assignment of System Data
194b
0Tenant Restriction Class Data (ATNR 
command)
Separate or Common 
Tenant Data table de-
velopment for the re-
spective commands
0/1 = Separate/Com-
mon
Note:When data 
“1” is 
assigned, 
data must be 
assigned for 
Tenant 1 
(TN = 1) in 
the respective 
commands. b
1EPN Facility Restriction Data (AEFR 
command)
b
2Primary Call Restriction Data (APCR 
command)
b
3Authorization Code Data (AATC 
command)
b
4Special Access Code for...

Page 135

NDA-24298 CHAPTER 4
Page 101
Issue 1
ASYD : Assignment of System Data
196
End User’s Office Name (INDEX 96-115)
Note 1:The End User’s Office Name must be less than 20
characters.
Note 2:A blank is assigned as data “20 Hex”.
Example:If the End User’s Office Name is “NEC CORP. 
(TOKYO),” assignment is as follows: 97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
SYSTEM
DATA
TYPE 
(SYS)SYSTEM 
DATA 
INDEX 
(INDEX)
0 – 511DATA 
(DATA) 
00 – FF 
(Hex)BIT 
CORRESPONDING 
DATA
SYSTEM DATA...

Page 136

CHAPTER 4 NDA-24298
Page 102
Issue 1
ASYD : Assignment of System Data
Note 1:
When setting the data that designates Print/Message Center and MAT, be sure the data is not duplicated in
the Port number data to be assigned by SYS-1, INDEX 288, 290, 292, and 294. Also, when setting the data
that designates SMDR, it is necessary to assign the corresponding data to SYS-1, INDEX 288, 290, 292,
and 294.
Note 2:Bits 0 ~ 6 are assigned in the AIOC command. Only bit 7 may be changed using this index.
Note 3:When...

Page 137

NDA-24298 CHAPTER 4
Page 103
Issue 1
ASYD : Assignment of System Data
Note 1:When setting the data that designates Print/Message Center and MAT, be sure the data is not duplicated in the Port
number data assigned by SYS-1, INDEX 288, 290, 292, and 294. When setting the data that designate SMDR, it is
necessary to assign the corresponding data to SYS-1, INDEX 288, 290, 292, and 294.
Note 2:Bits 0 ~ 6 are assigned in the AIOC Command. Only bit 7 may be changed using this index.
Note 3:When activating the...

Page 138

CHAPTER 4 NDA-24298
Page 104
Issue 1
ASYD : Assignment of System Data
Note 1:
When setting the data that designates Print/Message Center and MAT, be sure the data is not duplicated in the Port
number data assigned by SYS-1, INDEX 288, 290, 292, and 294. When setting the data that designate SMDR, it is
necessary to assign the corresponding data to SYS-1, INDEX 288, 290, 292, and 294.
Note 2:Bits 0 ~ 6 are assigned in the AIOC Command. Only bit 7 may be changed using this index.
Note 3:
When activating the...

Page 139

NDA-24298 CHAPTER 4
Page 105
Issue 1
ASYD : Assignment of System Data
Note:When activating the Password function, assign “b
7 = 1” ONLY after a Password Code has been assigned via com-
mand APSW.
Note:When activating the Password function, assign “b
7 = 1” ONLY after a Password Code has been assigned via
command APSW.
SYSTEM 
DATA 
TYPE 
(SYS)SYSTEM 
DATA  
INDEX 
(INDEX)
0 - 511DATA 
(DATA)
00 - FF
HEXBIT 
CORRESPONDING 
DATA
SYSTEM DATA CONTENTS
DATA
0/1BIT
11220
b0
Not used
Data for Port 6 of 
the IOC...

Page 140

CHAPTER 4 NDA-24298
Page 106
Issue 1
ASYD : Assignment of System Data
SYSTEM 
DATA
TYPE
(SYS)SYSTEM
DATA
INDEX
(INDEX)
0 - 511DATA
(DATA)
00 - FF
(Hex)BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1BIT
1124 00
Not used
125
b0MFC Sender PAD Control
Note:Source Signal is -8 dBm
b3b2b1b0
0 000 =-0 dB
0 001 =-2 dB
0 010 =-4 dB
0 011 =-6 dB
0 100 =-8 dB
0 101 =-10 dB
0 1 1 0 = -11.5 dB
0 111 =-14 dB
1 000- 1111 =Not used
b1
b2
b3
b4MFC Signaling System
b3b2b1b0
0 000=NEC Standard (Complies with the CCITT...