Page 101
NDA-24298 CHAPTER 4 Page 67 Issue 1 ASYD : Assignment of System Data SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 – 511DATA (DATA) 00 – FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT 170b 0Not used b 1 Restriction in the number of outside parties who can participate in the Station Controlled Conference. 0/1 = Not Required/Required If “0” is set, the outside party who can participate in the Station- Controlled Conference is as follows: (a) For Tie Lines, it is possible to...
Page 102
CHAPTER 4 NDA-24298 Page 68 Issue 1 ASYD : Assignment of System Data Note 1:Composition of Authorization Code, and its relation to Check Sum (related to INDEX 12~14). Authorization Code consists of D0 D1 D2 D3 D4 D5 D6. (When using Check Sum, a maximum of seven digits, including Check Digits, are available.) There is a maximum of two Check Digits and eight Seek Digits. D5 is determined by Check Sum-1 and Check Code-1. MOD10 (b 4 × D0 + b3 × D1 + b2 × D2 + b1 × D3 + b0 × D4 + D5) = Check Code-1 D6 is...
Page 103
NDA-24298 CHAPTER 4 Page 69 Issue 1 ASYD : Assignment of System Data SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 – 511DATA (DATA) 00 – FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT 113b 0Authorization Code Check Sum-2 b 4= Check Sum of Digit 0 b 3= Check Sum of Digit 1 b 2= Check Sum of Digit 2 b 1= Check Sum of Digit 3 b 0= Check Sum of Digit 4 0/1 = No Check Sum/Check Sum b 1 b2 b3 b4 b5 b6 b7 14b 0Authorization Code Check Code-1 (0~9 Hex.) Check Code = MOD 10 (b4 × D0...
Page 104
CHAPTER 4 NDA-24298 Page 70 Issue 1 ASYD : Assignment of System Data 116b 0 1-digit Station Number 0/1 = Out/In Service b 1 2-digit Station Number 0/1 = Out/In Service b 2 3-digit Station Number 0/1 = Out/In Service b 3 4-digit Station Number 0/1 = Out/In Service b 4 5-digit Station Number 0/1 = Out/In Service 0b 5 Not used 0b6 0b7 17b 0 This bit (data “1”) allows single line stations to switch hook flash and dial an access code while hearing RBT, to place a voice call to a or activate the D term’s...
Page 105
NDA-24298 CHAPTER 4 Page 71 Issue 1 ASYD : Assignment of System Data 118b 0 Not used b 1 b2 b3 b4 b5 b6 Day/Night change of Satellite Office (for CCIS) 0/1 = Out/In Service b 7 Day/Night change is executed by the Main Office (for CCIS) Note:If Day/Night change is executed at the Main Office when INDEX b 6 = 1 of the Main Office and b7 = 1 of the Satellite Office, Day/Night change is executed at the Satellite Office as per the Tenant of the Main Office. 0/1 = Out/In Service 19b 0n: Tenant (TN = 1 – 15) of...
Page 106
CHAPTER 4 NDA-24298 Page 72 Issue 1 ASYD : Assignment of System Data Note:When “1” has been assigned to b 7, the station number of Station A (Called Party), as shown below, is provided to the SMDS equipment. 120b 0 Not used b 1 b2 b3 b4 b5 b6 b7 Billing Party for a call transferred by Call Forwarding – Outside Service Note 0 = The Billing Party is the originator of the transferred call. 1 = The Billing Party is the station that has set Call Forwarding – Outside service. SYSTEM DATA TYPE (SYS)SYSTEM...
Page 107
NDA-24298 CHAPTER 4 Page 73 Issue 1 ASYD : Assignment of System Data SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 – 511DATA (DATA) 00 – FF (Hex)BIT CORRESPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT 121 00 Not used 22 00 Not used 23 00 Not used 24 00 Not used 25 00 Not used 26 00 Not used 270b 0 Not used 0b 1 0b2 0b3 0b4 0b5 0b6 0b7 Immediate Ring Back Tone Sending: 0/1 = Not Required/Required 128b 0 Miscellaneous Timer Counter (MTC) (00~1F Hex)Message sending Guard Timer for Message...
Page 108
CHAPTER 4 NDA-24298 Page 74 Issue 1 ASYD : Assignment of System Data 129b 0Message Center Interface Output Designation “1” is to be assigned to each bit corresponding to the Port Number of the IOC Circuit Card. b 0 = Port 0 b4 = Port 4 b 1 = Port 1 b5 = Port 5 b 2 = Port 2 b6 = Port 6 b 3 = Port 3 b7 = Port 7 Note:In the case of dual output ports service, assign “1” to both ports. b 1 b2 b3 b4 b5 b6 b7 30 Mounting capacity of Data Memory (DM) For IPX, assign 02 Hex. Note:Assign 04H for the extensive...
Page 109
NDA-24298 CHAPTER 4 Page 75 Issue 1 ASYD : Assignment of System Data 1330b 0 Not used 0b1 0b2 b3Telephone Subject to Total Billing (when b6 = 1) 0 0 = Telephone that called first 0 1 = Telephone that called last. 1 0 = First telephone after the call has been handled by AT T. 1 1 = Last telephone after the call has been handled by AT T. b 4 b5 Billing for Transferred Incoming Call 0/1 = Split/Total Billing Note:Total Billing means “Telephone that called last.” b 6 Billing for Transferred Outgoing Call...
Page 110
CHAPTER 4 NDA-24298 Page 76 Issue 1 ASYD : Assignment of System Data 134b 0 SMDR RS-232 C Output 0/1 = Out/In Service b 1RS-232C Output Code (SMDR) (When b0 = 1: SMDR) b2b1 0 0 = No Parity (If parity bit 7 is 0) 01=Not used 10=Not used 11=Not used b 2 b3Number of RS-232C stop bits b 4b3b4b3 00=–1 0 = 1 + 1/2 bits 0 1 = 1 bit 1 1 = 2 bits b4 b5 The converted number is sent to the SMDR. 0 = Original Number is sent. 1 = Converted Number is sent 0b 6Not used 0b 7 SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX...