Page 361
NDA-24306 CHAPTER 5 Page 333 Revision 1.0 Test Outline: The purpose of this test is to confirm, by setting up an incoming trunk connection test for each incoming trunk, that speech can be made with the ATTCON when a Ringdown Signal Interface is used, or with a station when a Dial-In Signal Interface is used. This test also confirms that the call can be released. Incoming trunks must be tested one at a time using the sequence of Route and Trunk Numbers assigned at each office. NAP-200-032 Sheet 1/2...
Page 362
CHAPTER 5 NDA-24306 Page 334 Revision 1.0 NAP-200-032 Sheet 2/2 Incoming Trunk (COT, TLT, DTI Card) Connection Test For a Dial-In Signal Interface.Station “A” dials the access code for the outgoing trunk and the telephone number of Station “B.” Station “B” answers the call and confirms speech. The call is released. Make temporary cross connections for the next trunk to be tested. Restore the temporary cross connections, temporary Office Data, etc. to the original. END AB
Page 363
NDA-24306 CHAPTER 5 Page 335 Revision 1.0 NAP-200-033 Sheet 1/1 Direct-In Termination Trunk (COT Card) Connection Test START On the MDF, make temporary cross connections between the Trunk for Direct-In Termination (DIT) and an LC. C.O. Line Incoming Call Station “B” dials the telephone number of LC “C” (Station “C”). Incoming Call to Station via DIT Trunk.The call terminates to Station “A”; Station “A” rings. Confirm that the ringing is distinct from that of an intra- office call or ordinary C.O....
Page 364
CHAPTER 5 NDA-24306 Page 336 Revision 1.0 NAP-200-034 Sheet 1/1 SND (RST Card) Connection Test START When a C.O. Line or Tie Line is not connected with the trunk, make an arrangement for trunk loop-back as illustrated above.On the MDF, make temporary cross connections for a loop back circuit. Temporarily assign Office Data from the MAT so that a connection can be set up with Station “B” via a SND. Make busy all SNDs On the front of the RST circuit card, set all MBS switches (0-7) to the OFF...
Page 365
NDA-24306 CHAPTER 5 Page 337 Revision 1.0 NAP-200-035 Sheet 1/1 3-party Conference Trunk Function Test START Make busy all CFTs Make busy all CFTs using MAT command “MBTK.” Test CFTs one at a time Un-busy (make idle) only the CFT to be tested. Stations “A” and “B” are engaged in a station to station connection. Station “A” makes a Switch Hook Flash (SHF) and after hearing dial tone, dials the telephone number of Station “C.” Station “C” answers the call. Station “A,” after having talked with Station...
Page 366
CHAPTER 5 NDA-24306 Page 338 Revision 1.0 NAP-200-036 Sheet 1/1 Connection Test-Announcement Trunk for Announcement Service START Dial the announcement service codeStation “A” dials the announcement service code. Check the contents of the announcementStation “A” is connected to the announcement machine and hears the announcement. Dial the announcement service codeStation “B” dials the announcement service code. Check the contents of the announcement Station “B” is connected to the announcement...
Page 367
NDA-24306 CHAPTER 5 Page 339 Revision 1.0 NAP-200-037 Sheet 1/1 Connection Test-Digital Announcement Trunk for Announcement Service START Dial the announcement service codeStation “A” dials the announcement service code. Check the contents of the announcementStation “A” is connected to the announcement trunk and hears the announcement. Dial the announcement service codeStation “B” dials the announcement service code. Check the contents of the announcementStation “B” is connected to the announcement...
Page 368
CHAPTER 5 NDA-24306 Page 340 Revision 1.0 NAP-200-038 Sheet 1/1 Connection Test-Paging Trunk for Paging Access Service START Dial the paging access code Station “A”/ATTCON dials the paging access code and hears CRBT (Continuous Ringback Tone). In about 1 sec., CRBT stops. Speaker Paging Check whether speaker paging is possible after CRBT has stopped. Release Station “A” goes on-hook or the ATTCON depresses the CANCEL key. END LCA AT T C O N PGT AMP SP
Page 369
NDA-24306 CHAPTER 5 Page 341 Revision 1.0 Paging Transfer Service can be selected according to System Data (SYS1, INDEX 73). 1. Non-Delay System 2. Delay and Non-Delay System 3. Paging Transfer Supervision NAP-200-039 Sheet 1/2 Connection Test-Paging Trunk for Paging Transfer Service START Call the Paging Trunk Stations “A” and “B” are engaged in a station to station connection. Station “A” makes a Switch Hook Flash (SHF) and hears SPDT. Station “B” is held on the line. Station “A” dials the paging...
Page 370
CHAPTER 5 NDA-24306 Page 342 Revision 1.0 NAP-200-039 Sheet 2/2 Connection Test-Paging Trunk for Paging Transfer Service Connection For Non-Delay-System Station “C” is connected to Station “A.” When Station “A” hangs up, Stations “B” and “C” are automatically connected with each other. For a Delay-System Station “A” rings and picks up handset. Station “A” is connected to Stations “C.” When Station “A” hangs up, Stations “B” and “C” are automatically connected with each other. For Paging Transfer...