Page 351
NDA-24306 CHAPTER 5 Page 323 Revision 1.0 NAP-200-026 Sheet 5/5 System Initialization Test Perform the total system initialization by powering ON/OFF On all PWR supplies, set the circuit breaker OFF (DOWN). If a module contains two PWR supplies, they must be turned OFF simultaneously. For LNs: IMG3 IMG2 IMG1 IMG0 IMG3: PIM3PIM2PIM1PIM0 IMG2: PIM3PIM2PIM1PIM0TSWM1 IMG1: PIM3PIM2PIM1PIM0TSWM0 IMG0: PIM3PIM2PIM1PIM0CPR1CPR0 For ISW: ISWM CPR1 CPR0 Turn ON the PWR supplies in each module in the...
Page 352
CHAPTER 5 NDA-24306 Page 324 Revision 1.0 NAP-200-027 Sheet 1/1 Circuit Card Initialization Test START Make the No. 0 CPU into active state. In each PIM, initialize any Line/Trunk circuit card.On the selected Line/Trunk circuit card, set the MB switch UP. The OPE lamp goes out. System Message “7-K” is displayed. Set the MB switch DOWN. The OPE lamp illuminates. System Message “7-L” is displayed. Clear the alarm Clear the alarm indication by pressing the “ALM RST” button on the TOPU. Place the No. 1 CPU...
Page 353
NDA-24306 CHAPTER 5 Page 325 Revision 1.0 4. PORT CONNECTION TEST 4.1 Outline Tests are to be performed on all the circuits of LC and Trunk circuit cards and PWR Supplies. LC and Trunk circuit cards are tested with respect to their operations and speech path conditions. PWR Supplies are tested with respect to howler tone and ringing signal. While tests are in progress, the No. 0 CPU and TSW systems must be ACT (active). 4.2 Port Connection Test Procedure The connection test procedure for each type of...
Page 354
CHAPTER 5 NDA-24306 Page 326 Revision 1.0 NAP-200-028 Sheet 1/2 ORT (RST Card) Connection Test START Make busy all ORTs On the front of the RST card, set all MBR switches (0-7) to the OFF position, making all ORTs busy. From Station “A” (DP), test ORTs one circuit at a time.Un-busy (make idle) only the ORT to be tested. Station “A” goes off-hook and after hearing dial tone, dials the station number of Station “B.” Station “A” confirms ringing to Station “B” and Station “B” answers. Stations “A” and...
Page 355
NDA-24306 CHAPTER 5 Page 327 Revision 1.0 NAP-200-028 Sheet 2/2 ORT (RST Card) Connection Test Perform tests for a situation where all ORTs are busy. System Data SYS1, INDEX 4, b 0 =0Station “A” goes off-hook. Station “A” confirms that reorder tone is heard. Station “A” goes off-hook. System Data SYS1, INDEX 4, b 0 =1Station “A” goes off-hook. Station “A” confirms that no tone is heard. Un-busy (make idle) a single ORT circuit. Station “A” confirms that dial tone is heard. Station “A” goes off-hook....
Page 356
CHAPTER 5 NDA-24306 Page 328 Revision 1.0 NAP-200-029 Sheet 1/1 ATTCON (ATI Card) Connection Test START A station repeats an ATTCON call. Each ATTCON answers the call.Station “A” dials the operator access code (normally, “0”). At each ATTCON, the operator confirms that the ATT lamp flashes and the ringer sounds. At each ATTCON, the operator answers the call by pressing the ATND key. Station “A” confirms speech with each ATTCON. The operator at each ATTCON releases by pressing the CANCEL key. Station...
Page 357
NDA-24306 CHAPTER 5 Page 329 Revision 1.0 NAP-200-030 Sheet 1/1 Line (LC, ELC, DLC Card) Connection Te s t START An ATTCON or Dterm is called from each station. The called party confirms the station number.On the MDF, a telephone set is connected to the line circuit to be tested The station (XXXX) to be tested goes off-hook and confirms dial tone. The station (XXXX) calls an ATTCON or D term. The called ATTCON or D term answers the call, and confirms speech and the station number of the calling...
Page 358
CHAPTER 5 NDA-24306 Page 330 Revision 1.0 Test Outline: The purpose of this test is to confirm, by setting up an outgoing connection test for each outgoing trunk, that speech can be made and that the call can be released. Outgoing trunks must be tested one at a time using the sequence of Routes and Trunk Numbers assigned at each office. NAP-200-031 Sheet 1/3 Outgoing Trunk (COT, TLT, DTI Card) Connection Test START When a C. O. Line or Tie Line is not connected with a trunk circuit, temporary cross...
Page 359
NDA-24306 CHAPTER 5 Page 331 Revision 1.0 Set up a loop-back connection between the COT (C.O. Trunk) to be tested and a station line. Figure 031-1 COT Test Configuration The trunk route must be assigned for Loop Start. Figure 031-2 TLT Test Configuration Set up a loop-back connection between the TLT (Tie Line Trunk) to be tested and another EMT. If the TLT is a DID (Direct Inward Dialing) Trunk, connect the related leads as shown below. If the TLT is a 2W E&M System, connect the related leads...
Page 360
CHAPTER 5 NDA-24306 Page 332 Revision 1.0 If the TLT is a 4W E&M System, connect the related leads as shown below. Set up a loop-back connection between the DTI Trunk to be tested and another DTI Trunk as shown below: Figure 031-3 DTI Test Configuration If the office is the primary office (Clock-Source-Office), perform the tests by disconnecting the PLO and the M-OSC. (The mode of the PLO becomes “Self Operation Mode.”) NAP-200-031 Sheet 3/3 Outgoing Trunk (COT, TLT, DTI Card) Connection Test T...