Page 331

NDA-24306 CHAPTER 5
Page 303
Revision 1.0
INSTALLATION TEST PROCEDURE
Note:
For this test, there are three patterns for connections which possibly can be set up. Refer to Figure 024-1
on the next page.
NAP-200-024
Sheet 1/2
Station to Station Connection Test
START
Confirm that a connection can be established between Station “A” and Station “B.”
Station “A” goes off-hook.
Station “A” hears dial tone.
Station “A” dials the station number of Station “B.”
Station “A” confirms that dial tone stops when the...

Page 332

CHAPTER 5 NDA-24306
Page 304
Revision 1.0
INSTALLATION TEST PROCEDURE
Figure 024-1  Station-to-Station Connection Test
NAP-200-024
Sheet 2/2
Station to Station Connection Test
LC/
ELC
ORT dial tone, reorder tone
Self-Node
(ex. LN0)Other Node
     (ex. LN1)
ISW
Fusion Link
FCCS LinkFusion Link STN ASTN B
RG
Dial
 
TE
LN
Di
al
 
TE
LNDi
al
 
TE
LN
LC/
ELC
ORT
dial tone, reorder tone
Self-Node
(ex. LN0)
ISW
STN A
STN B
ORT
dial tone, reorder tone
Self-Node
(ex. LN0)
STN A



ISW: Inter-node Switch
LN: Local...

Page 333

NDA-24306 CHAPTER 5
Page 305
Revision 1.0
INSTALLATION TEST PROCEDURE
3. SYSTEM INITIALIZED TEST
3.1 Outline
Tests are to be performed on the restart processing (reinitialization) and system changeover functions which en-
able the system to restart its operations and services.
3.2 System Initialized Test Procedure
The System Changeover Test and Initialization Tests are to be performed per the NAP Numbers indicated to the
right of each item in the following flowchart.
START
System Changeover...

Page 334

CHAPTER 5 NDA-24306
Page 306
Revision 1.0
INSTALLATION TEST PROCEDURE
Test Outline
Tests are to be performed to see if the ACT/ST-BY of the following equipment is normally changed over:
1. Control Systems in each Local Node (LN)
2. Control Systems in ISW
3. Speech Path Systems in each LN (TSWM0/TSWM1)
4. Speech Path Systems in ISW + all LNs as a whole
5. PLO
NAP-200-025
Sheet 1/13
System Changeover Test
AT T E N T I O NContents
Static Sensitive
Handling
Precautions Required 

Page 335

NDA-24306 CHAPTER 5
Page 307
Revision 1.0
INSTALLATION TEST PROCEDURE
1. Control System changeover in each LN
Follow the procedures below to perform the Control System changeover tests in each Local Node (LN). This
test must be performed in each LN independently:
Note:This changeover can also be performed via the CMODI/CMOD command. Refer to the “System Operations
and Maintenance Manual.”
Figure 025-1  DSP in ACT/ST-BY Mode (Local Node)
NAP-200-025
Sheet 2/13
System Changeover Test
START
Control System...

Page 336

CHAPTER 5 NDA-24306
Page 308
Revision 1.0
INSTALLATION TEST PROCEDURE
2. Control System changeover in ISW
Follow the procedures below to perform the Control System changeover tests in ISW:
Note:This changeover can also be performed via the CMODI command. Refer to the “System Operations and
Maintenance Manual.”
Figure 025-2  DSP in ACT/ST-BY Mode (ISW)
NAP-200-025
Sheet 3/13
System Changeover Test
START
Control System changeover 
via MBR key on the CPR 
DSP (PZ-DK224)On the CPR DSP on which CPU OPE lamp...

Page 337

NDA-24306 CHAPTER 5
Page 309
Revision 1.0
INSTALLATION TEST PROCEDURE
3. Speech Path System changeover in each ISW
Follow the procedures below to perform the Speech Path System changeover tests in ISW:
Note:This changeover can also be performed via the CMODI/CMOD command. Refer to the “System Operations
and Maintenance Manual.”
Note:If you change over from LNs, the entire system will be changed over. Therefore, it is best to change over
from ISW.
NAP-200-025
Sheet 4/13
System Changeover Test
START
Change...

Page 338

CHAPTER 5 NDA-24306
Page 310
Revision 1.0
INSTALLATION TEST PROCEDURE
4. Total Speech Path System changeover
Perform the total Speech Path System changeover test by referring to the flowchart below. As suggested in the 
previous page, the ACT/ST-BY of Speech Path Systems can be differently set in every Local Node (LN). How-
ever, excepting a particular case, the Speech Path changeover is normally performed on a system basis as shown
in this page:
Note:This changeover can also be performed via the...

Page 339

NDA-24306 CHAPTER 5
Page 311
Revision 1.0
INSTALLATION TEST PROCEDURE
Figure 025-3  LEDs and Switches for Speech Path System Changeover
NAP-200-025
Sheet 6/13
System Changeover Test
AT T E N T I O NContents
Static Sensitive
Handling
Precautions Required
green
TSW ACT
MB
MBR
PH-GT10
IOGT: Active
TSW ACT
TSW ACTTSW ACT
TSW ACT
TSW ACTHSW ACT
HSW ACTMUX ACTOPE/MB
OPE/MB MUX ACT MBMB
MB
MB
MB
MB
MBMBMB
MBR
TSW MBR TSW MBRTSW MB
TSW MBRTSW MBTSW MBR
TSW: Active HSW: Active TSW: Active MUX: Active DLKC:...

Page 340

CHAPTER 5 NDA-24306
Page 312
Revision 1.0
INSTALLATION TEST PROCEDURE
5. PLO changeover
Perform the PLO changeover test referring to the flowchart below.
NAP-200-025
Sheet 7/13
System Changeover Test
START
Change over the ACT/ST-BY of the PLO systems in each LN via key operation.
On the active PLO (PH-CK16-A) card in TSWM0, flip the MB key DOWN →  UP →  DOWN 
(OFF → ON → OFF).
Make sure that the ACT/ST-BY of the whole PLO systems (PLO in TSWM0 and CLK in 
TSWM1) in the same Local Node (LN) are totally...