Page 281
NDA-24306 CHAPTER 3 Page 253 Revision 1.0 2. [HEADSET TYPE] This item specifies the type of Headset connected to the H/S1 connector. a) Press the desired number. An asterisk shows the selected number. 1: The type of Headset is “SUPRA” 2: The type of Headset is “COROLLE” SRC: Return to Configuration Menu Note:Default setting is “1: SUPRA”. b) Press the SRC key. The display returns to Configuration Menu. c) When configuration data assignment is finished, proceed to [Updating Configuration Data] on Page...
Page 282
CHAPTER 3 NDA-24306 Page 254 Revision 1.0 3. [MUTE] This item specifies On/Off setting of the mute function for the HAND H/S0 or H/S1 connector. While the mute function is set to On, if the Mute key is pressed, the voice at the DESK CONSOLE side is not sent to the other party. a) Press the desired number. An asterisk shows the selected number. 1: Both H/S0 and H/S1 are set to On 2: Only H/S0 is set to On 3: Only H/S1 is set to Off SRC: Return to Configuration Menu Note:Default setting is “1: H/S0 ON,...
Page 283
NDA-24306 CHAPTER 3 Page 255 Revision 1.0 4. [REC CONTROL] This item specifies the operation mode of a recording device. The following two types of modes are available: [Manual mode] Manual mode is available when the REC circuit card is mounted in the system. When the REC key is pressed, the system starts recording and the REC lamp lights. When the REC key is pressed again, the recording stops and the REC lamp goes off. [Automatic mode] In Automatic mode, a dedicated recording device is directly...
Page 284
CHAPTER 3 NDA-24306 Page 256 Revision 1.0 5. [SUP CONNECTION] This item specifies whether the supervisory console is connected or not. a) Press the desired number. An asterisk shows the selected number. 1: Supervisory Console is connected 2: Supervisory Console is not connected SRC: Return to Configuration Menu Note:Default setting is “1: NONE”. b) Press the SRC key. The display returns to Configuration Menu. Note:Do Not change this data. c) When configuration data assignment is finished, proceed to...
Page 285
NDA-24306 CHAPTER 3 Page 257 Revision 1.0 6. [REC VOLUME ADJUSTMENT] This item specifies the recording level of the received voice from the other party. Note that the voice level at the operator side cannot be adjusted. a) Press the desired number. An asterisk shows the selected number. 1: +2dB Up 2: 0dB (Standard level) 3: -4dB Down 4: -8dB Down SRC: Return to Configuration Menu Note:Default setting is “2: 0dB”. b) Press the SRC key. The display returns to Configuration Menu. c) When configuration data...
Page 286
CHAPTER 3 NDA-24306 Page 258 Revision 1.0 7. [BLF] This item specifies On/Off setting of the BLF function. When using BLF function, system data assignment is also required. a) Press the desired number. An asterisk shows the selected number. 1: BLF Available 2: BLF Not available SRC: Return to Configuration Menu Note:Default setting is “2: DISABLE”. b) Press the SRC key. The display returns to Configuration Menu. c) When configuration data assignment is finished, proceed to [Updating Configuration Data]...
Page 287
NDA-24306 CHAPTER 3 Page 259 Revision 1.0 8. [HOLD/START/RELEASE/SWAP] This item specifies the locations of HOLD, START and RELEASE key. a) Press the desired number. An asterisk shows the selected number. 1: Original setting 2: Swapped setting Note:The locations of each key changes as shown below. SRC:Return to Configuration Menu Note:Default setting is “1: ORIGINAL”. b) Press the SRC key. The display returns to Configuration Menu. c) When configuration data assignment is finished, proceed to [Updating...
Page 288
CHAPTER 3 NDA-24306 Page 260 Revision 1.0 [Updating Configuration Data] When configuration data assignment is complete, update configuration data according to the procedure below. When the RELEASE key is pressed, update is cancelled. While one of the Configuration Menu is displayed on the LCD, press the ANSWER key. Configuration data is updated and the DESK CONSOLE is automatically restarted. NAP-200-015 Sheet 41/41 Installation of the DESK CONSOLE and Cable Connection Alarm Position Available LDNTIE...
Page 289
NDA-24306 CHAPTER 3 Page 261 Revision 1.0 This NAP explains the installation of the MAT (Maintenance Administration Terminal) and the System Message Printer focusing on their cable connections. 1. INSTALLATION OF MAT AND CABLE CONNECTIONS NAP-200-016 Sheet 1/9 Installation of the Maintenance Administration Terminal (MAT) and Cable Connections START Preparation of the MAT Set up the Personal Computer, CRT Display, Printer, and so on. Cable Connection Connect the cables between the MAT and the PBX...
Page 290
CHAPTER 3 NDA-24306 Page 262 Revision 1.0 Figure 016-1 Cabling of MAT when Using Ethernet NAP-200-016 Sheet 2/9 Installation of the Maintenance Administration Terminal (MAT) and Cable Connections 00 01 02 03 04 05 06 07 08 09 10 11 00 01 02 03 04 05 06 07 08 09 10 1112 13 14 15 16 17 18 19 20 21 22 23 LANI (PZ-PC19) MAT HUB BASEULPM 10BASET (straight) PH-PC40(EMA) PH-IO24(IOC) Note