Page 251
NDA-24306 CHAPTER 3 Page 223 Revision 1.0 Note:When replacing Attendant Console with DESK CONSOLE, follow the procedure below: (a) Turn OFF the PWR card in the PIM. (b) Remove installation cables connected to ATT0, ATT1 and LT connectors on the ATT TERM. (c) Remove installation cables connected to the following connectors: RLT connector on the ATT TERM ATI0 and LT5, ATI1 and LT11 connectors on the PIM (d) Install DESK CONSOLE using the LT connector on the ATT TERM. (e) Turn ON the PWR card in the...
Page 252
CHAPTER 3 NDA-24306 Page 224 Revision 1.0 Cable Connection Diagram a) When the power is supplied from the PBX Figure 015-3 Cable Connection Diagram (When the power is supplied from the PBX) When exceeding the distance above, calculate the distance referring to instructions on the next page. NAP-200-015 Sheet 5/41 Installation of the DESK CONSOLE and Cable Connection The maximum distance between the ATI circuit card and DESK CONSOLE is as shown below. Source 0.5 φ Cable 0.65 φ Cable PBX 350 m (1148...
Page 253
NDA-24306 CHAPTER 3 Page 225 Revision 1.0 Calculation of the distance between the ATI circuit card and Modular Rosette The distance M in Figure 015-3 is determined according to the Direct-Current resistance of power supply cables (–48V and GND). Note that the maximum resistance is 26 Ω as shown in the following formula: M = a + b + c ≤ 26 Ω M: Maximum Direct–Current resistance between the ATI circuit card and Modular Rosette a: Direct-Current resistance of power supply cables (–48V and GND) in the range...
Page 254
CHAPTER 3 NDA-24306 Page 226 Revision 1.0 b) When using Local Power Supply Note Note: When using local power supply, DESK CONSOLE cannot be used in case of power failure. Figure 015-4 Cable Connection Diagram (When using Local Power Supply) NAP-200-015 Sheet 7/41 Installation of the DESK CONSOLE and Cable Connection The maximum distance between the ATI circuit card and DESK CONSOLE is as shown below. Source 0.5φCable 0.65φCable Local Power Supply 1,200 m (3937 ft.) 1,500 m (4921 ft. 3 in.) A2 PBX AT...
Page 255
NDA-24306 CHAPTER 3 Page 227 Revision 1.0 Figure 015-5 Cable Connection Diagram for DESK CONSOLE Modular Block NAP-200-015 Sheet 8/41 Installation of the DESK CONSOLE and Cable Connection Wire the cables to the Modular Block as shown below. Bottom View DESK CONSOLE PA G E (8-core)LINE (6-core)REC (8-core) 6-core Modular Cable6-core Modular BlockIDF/MDF DESK CONSOLE TransformerSurge Protection DC/DC ConvertorGND –48V/–24V Desk Console Modular Jack6-core Modular Cable PIN No. 26 27LEAD NAMEPIN No. 1...
Page 256
CHAPTER 3 NDA-24306 Page 228 Revision 1.0 Mounting of Headset (Optional) The Headset cable is connected to one of the modular jacks (HAND H/S 0 or H/S 1) on the bottom of DESK CONSOLE. Figure 015-6 Headset NAP-200-015 Sheet 9/41 Installation of the DESK CONSOLE and Cable Connection Voice Tube Note:In daily use, use Quick Disconnect when connecting/disconnecting the Headset. Slide Closing Clip Quick Disconnect PIN1 TX 2 RX 3 RX 4 TX PIN1 (+) (–) Modular Plag Note Slide Ear Pad Slide Head Band Capsule...
Page 257
NDA-24306 CHAPTER 3 Page 229 Revision 1.0 Mounting of Handset (Optional) The Handset cable is connected to the modular jack (HAND H/S 0) on the bottom of DESK CONSOLE. a) When mounting at the left side of DESK CONSOLE (Standard) Figure 015-7 Mounting of Handset (Left side of DESK CONSOLE) NAP-200-015 Sheet 10/41 Installation of the DESK CONSOLE and Cable Connection 1. Put the Handset code through the hole as shown below. (DESK CONSOLE side) (Handset side) Handset code Hole Side View L1 L2 L3 L4 L5...
Page 258
CHAPTER 3 NDA-24306 Page 230 Revision 1.0 Figure 015-7 Mounting of Handset (Left side of DESK CONSOLE) (Continued) NAP-200-015 Sheet 11/41 Installation of the DESK CONSOLE and Cable Connection 2. Connect the Handset code to HAND H/S0 connector as shown below (H/S1 is not used for the Handset). Bottom View of DESK CONSOLE Top ViewBottom View Hand H/S0 H/S1Handset code
Page 259
NDA-24306 CHAPTER 3 Page 231 Revision 1.0 Figure 015-7 Mounting of Handset (Left side of DESK CONSOLE) (Continued) NAP-200-015 Sheet 12/41 Installation of the DESK CONSOLE and Cable Connection Mount the Handset Support to DESK CONSOLE with three screws as shown below. Handset Supportprojection projection
Page 260
CHAPTER 3 NDA-24306 Page 232 Revision 1.0 b) When mounting at the right side of DESK CONSOLE Figure 015-8 Mounting of Handset (Right side of DESK CONSOLE) NAP-200-015 Sheet 13/41 Installation of the DESK CONSOLE and Cable Connection 2. Put the Handset code through the hole as shown below. 1. Remove the metal plate from the Handset, turn it over, and mount it to the Handset again. Refer to the figure below. Handset Metal PlateWhen mounting at the right sideWhen mounting at the left side Turn the...