NDA-24306 CHAPTER 3 Page 193 Revision 1.0 This NAP explains the following work items: NAP-200-014 Sheet 1/27 Cable Termination and Cross Connections from MDF to Peripheral Equipment, C. O. Lines, and Tie Lines MDF C.O. Line/ Tie LineCross Connection of Stations Cross Connection of Trunks (C.O. Lines and Tie Lines) Cross Connections for PFT Cross connection of Alarm Indicating Panel and Cross connections for TAS indicator Cross connections for External Switches Connection of Announcement...
Page 222
CHAPTER 3 NDA-24306 Page 194 Revision 1.0 1. CROSS CONNECTION OF STATIONS Note 1:Provide the necessary cross connections at the MDF by using copper wires of 0.5 mm diameter (24 AWG). 2-core twisted wire is used for speech path, and single-core wire is used for control wire. It is recommended that wires of different colors be used for trunks, station lines, PFT, etc., so that they can easily be distinguished. Note 2:For cross connections between stations and C.O. lines for PFT, refer to Section 3. “CROSS...
Page 223
NDA-24306 CHAPTER 3 Page 195 Revision 1.0 2. CROSS CONNECTION OF TRUNKS (C.O. LINES AND TIE LINES) Note 1:Provide the necessary cross connections at the MDF by using copper wires of 0.5 mm diameter (24 AWG). 2-core twisted wire is used for speech path, and single-core wire is used for control wire. It is recommended that wires of different colors be used for trunks, station lines, PFT, etc., so that they can easily be distinguished. Note 2:For cross connections between stations and C.O. lines for PFT,...
Page 224
CHAPTER 3 NDA-24306 Page 196 Revision 1.0 Figure 014-2 Cross Connection of Trunks (C.O. Lines and Tie Lines) NAP-200-014 Sheet 4/27 Cable Termination and Cross Connections from MDF to Peripheral Equipment, C. O. Lines, and Tie Lines AX BX 16COT CARDC.O. LINE Module Group Side AX BX 8TLT CARDTIE LINE TA X RAX 8TLT CARD TIE LINE EX MX TBX RBX (1) 16COT card (3) 8TLT card (for E&M Trunk) (2) 8TLT card (for DID Trunk) Note 1 Note 1:For 2W/4W E&M systems, these leads are not used. Note 2:For No. 4–7...
Page 225
NDA-24306 CHAPTER 3 Page 197 Revision 1.0 3. CROSS CONNECTIONS FOR PFT Note 1:The COT must be accommodated in a universal slot of the same Unit (U) in which the cross-connected PFT is mounted. See the figure below. Note 2:Provide the necessary cross connections at the MDF by using copper wires of 0.5 mm diameter (24 AWG). 2-core twisted wire is used for speech path, and single-core wire is used for control wire. It is recommended that wires of different colors be used for trunks, station lines, PFT,...
Page 226
CHAPTER 3 NDA-24306 Page 198 Revision 1.0 Figure 014-4 Cross Connection for PFT NAP-200-014 Sheet 6/27 Cable Termination and Cross Connections from MDF to Peripheral Equipment, C. O. Lines, and Tie Lines PBX COT PFT(PA-M53) CardLT AXX BXX LT AXX BXX MDF MDF NCU ROXX TOXX RIXX TIXX NCU AOXX BOXX AIXX BIXX Analog TelephoneInstallation Cable : When PIM Power is OFF : When PIM Power is ON LC Central Office
Page 227
NDA-24306 CHAPTER 3 Page 199 Revision 1.0 4. CROSS CONNECTION OF ALARM INDICATING PANEL AND MUSIC ON HOLD Note:Provide the necessary cross connections at the MDF by using copper wires of 0.5 mm diameter (24 AWG). 2-core twisted wire is used for speech path, and single-core wire is used for control wire. It is recommended that wires of different colors be used for trunks, station lines, PFT, etc., so that they can easily be distin- guished. Alarm Indicating Panel Music On Hold NAP-200-014 Sheet 7/27...
Page 228
CHAPTER 3 NDA-24306 Page 200 Revision 1.0 Figure 014-5 Connection of Alarm Indicating Panel NAP-200-014 Sheet 8/27 Cable Termination and Cross Connections from MDF to Peripheral Equipment, C. O. Lines, and Tie Lines Locations of Terminal and Connector General Cable Connection for Alarm Indicating Panel FRONT VIEW RPT Terminal (PZ-M377) TPWR FA L M -48VGND (RPT0) (RPT1) LPR BASEU 01234 1234 512 34 5 01 02 03 04 05 01 02 03 04 05 -48V (RPT0)G (RPT1) AUDIBLE AND VISUAL ALARM INDICATING PANEL MDFMJ...
Page 229
NDA-24306 CHAPTER 3 Page 201 Revision 1.0 Figure 014-5 Connection of Alarm Indicating Panel (Continued) Figure 014-6 Connection of Music on Hold NAP-200-014 Sheet 9/27 Cable Termination and Cross Connections from MDF to Peripheral Equipment, C. O. Lines, and Tie Lines 68PH EXMISC CA cable Pin Assignment MISC0A12 11 10 9 8 7 6 5 4 3 2 1MPALM EXTAA BELAA - MNAA SUPAA MJAA37 36 35 34 33 32 31 30 29 28 27 26MNBA SUPBA MJBABELAA MNAA SUPAA MJAA BELBA MNBA SUPBA MJBA RPT1(G) RPT0(-48V) MDF...
Page 230
CHAPTER 3 NDA-24306 Page 202 Revision 1.0 5. CROSS CONNECTIONS FOR TAS INDICATOR Note:Provide the necessary cross connections at the MDF by using copper wires of 0.5 mm diameter (24 AWG). 2-core twisted wire is used for speech path, and single-core wire is used for control wire. It is recommended that wires of different colors be used for trunks, station lines, PFT, etc., so that they can easily be distin- guished. NAP-200-014 Sheet 10/27 Cable Termination and Cross Connections from MDF to Peripheral...